8 resultados para Gracia

em Universidad de Alicante


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose. To assess in a sample of normal, keratoconic, and keratoconus (KC) suspect eyes the performance of a set of new topographic indices computed directly from the digitized images of the Placido rings. Methods. This comparative study was composed of a total of 124 eyes of 106 patients from the ophthalmic clinics Vissum Alicante and Vissum Almería (Spain) divided into three groups: control group (50 eyes), KC group (50 eyes), and KC suspect group (24 eyes). In all cases, a comprehensive examination was performed, including the corneal topography with a Placidobased CSO topography system. Clinical outcomes were compared among groups, along with the discriminating performance of the proposed irregularity indices. Results. Significant differences at level 0.05 were found on the values of the indices among groups by means of Mann-Whitney-Wilcoxon nonparametric test and Fisher exact test. Additional statistical methods, such as receiver operating characteristic analysis and K-fold cross validation, confirmed the capability of the indices to discriminate between the three groups. Conclusions. Direct analysis of the digitized images of the Placido mires projected on the cornea is a valid and effective tool for detection of corneal irregularities. Although based only on the data from the anterior surface of the cornea, the new indices performed well even when applied to the KC suspect eyes. They have the advantage of simplicity of calculation combined with high sensitivity in corneal irregularity detection and thus can be used as supplementary criteria for diagnosing and grading KC that can be added to the current keratometric classifications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

En este trabajo hemos cuantificado las tasas de deformación actual de la cuenca del Bajo Segura (NE del corredor de cizalla de la Bética oriental), a partir del análisis de una red GPS con 11 vértices geodésicos. Se han analizado los datos de cuatro campañas GPS entre junio de 1999 y enero de 2013, que han sido procesados con la versión 6.2 del software GIPSY-OASIS. Este software utiliza la técnica de posicionamiento puntual de precisión conocido por las siglas PPP. Se observa un acortamiento ~N-S en toda la cuenca de mayor magnitud en el sur, en la zona de falla del Bajo Segura, con valores que varían de oeste a este entre 0,73 y 0,24 mm/año. En el borde septentrional de la cuenca, en la zona de falla de Crevillente, los valores de acortamiento N-S son menores. Sin embargo, en esta falla se ha observado un movimiento lateral sinistrorso que, en la componente E-O, varía entre 0,44 y 0,75 mm/año.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The mechanical response of the cornea subjected to a non-contact air-jet tonometry diagnostic test represents an interplay between its geometry, the corneal material behavior and the loading. The objective is to study this interplay to better understand and interpret the results obtained with a non-contact tonometry test. A patient-specific finite element model of a healthy eye, accounting for the load free configuration, was used. The corneal tissue was modeled as an anisotropic hyperelastic material with two preferential directions. Three different sets of parameters within the human experimental range obtained from inflation tests were considered. The influence of the IOP was studied by considering four pressure levels (10–28 mmHg) whereas the influence of corneal thickness was studied by inducing a uniform variation (300–600 microns). A Computer Fluid Dynamics (CFD) air-jet simulation determined pressure loading exerted on the anterior corneal surface. The maximum apex displacement showed a linear variation with IOP for all materials examined. On the contrary, the maximum apex displacement followed a cubic relation with corneal thickness. In addition, a significant sensitivity of the apical displacement to the corneal stiffness was also obtained. Explanation to this behavior was found in the fact that the cornea experiences bending when subjected to an air-puff loading, causing the anterior surface to work in compression whereas the posterior surface works in tension. Hence, collagen fibers located at the anterior surface do not contribute to load bearing. Non-contact tonometry devices give useful information that could be misleading since the corneal deformation is the result of the interaction between the mechanical properties, IOP, and geometry. Therefore, a non-contact tonometry test is not sufficient to evaluate their individual contribution and a complete in-vivo characterization would require more than one test to independently determine the membrane and bending corneal behavior.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

El Trabajo de la Red reflexiona acerca de modos de retro-alimentar las prácticas docentes arquitectónicas y sociológicas con metodologías aparentemente exclusivas de cada una de ellas. La Red está formada por investigadores docentes y estudiantes de ambas ramas de conocimiento y acaba cristalizando en una serie de acciones para los cuales los miembros de la red son ponentes u observadores-narradores. Tras una serie de reuniones introductorias llevadas a cabo desde finales de 2013, la escenificación de los acuerdos se realizó el 6 de marzo de 2014 entorno a una mesa tapizada con la cartografía de Alicante y Murcia en el aula 4 del Politécnico IV de la UA. En ella, los ponentes fueron explicando sus propuestas mientras colocaban unos indicadores en el mapa de la región de Murcia y Alicante a la espera de adhesiones para formar grupos. Coincidiendo con el final del curso académico, las propuestas de análisis tuvieron lugar y son expuestas, resumidamente, en esta memoria de Red.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Diurnal changes in corneal geometry, pachymetry, and intraocular pressure (IOP) in a healthy eye were recorded. The deformation response to an air puff was simulated using 3 levels of corneal stiffness. The response was dependent on IOP and pachymetry and not only on the biomechanical properties of the cornea. Similarly, the maximum variability due to the diurnal changes in pachymetry and IOP in the corneal displacement generated by the air puff was found to reach 5%. Therefore, diurnal changes in IOP and corneal thickness were able to induce some variability in the air puff–based corneal deformation response. This potential variability should be considered when the biomechanical properties of the cornea are analyzed with air-puff devices.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The organocatalytic activities of highly substituted proline esters obtained through asymmetric [3+2] cycloadditions of azomethine ylides derived from glycine iminoesters have been analyzed by 19F NMR and through kinetic isotope effects. Kinetic rate constants have been determined for unnatural proline esters incorporating different substituents. It has been found that exo-L and endo-L unnatural proline methyl esters yield opposite enantiomers in aldol reactions between cyclic ketones and aromatic aldehydes. The combined results reported in this study show subtle and remote effects that determine the organocatalytic behavior of these synthetic but readily available amino acid derivatives. These data can be used as design criteria for the development of new pyrrolidine-based organocatalysts.