2 resultados para Floor Plate
em Universidad de Alicante
Resumo:
The impact noise reduction provided by floor coverings is usually obtained in laboratory, using the methodology described in the standard EN ISO 140-8, which requires the use of standard acoustic chambers. The construction of such chambers, following the requirements described in the EN ISO 140-1, implies a significant investment, and therefore only a limited number exists in each country. Alternatives to these standard methodologies, that allow a sufficiently accurate evaluation and require lower resources, have been interesting many researchers and manufacturers. In this paper, one such strategy is discussed, where a reduced sized slab is used to determine the noise reduction provided by floor coverings, following the procedure described in the ISO/CD 16251-1 technical document. Several resilient coverings, floating floors and floating slabs are tested and the results are compared with those obtained using the procedures described in the standards EN ISO 140-8 and EN ISO 717-2.
Resumo:
This article analyzes the relationship between two types of performances, one on the ground (of a tennis court) and the other on the floor (of the stock market). The empirical application looks into the tennis player, Rafael Nadal, and his endorsing firms. The findings show a positive reaction in the market value when the tennis player wins matches in the Grand Slams, the intriguing effect being the diminishing sensitivity pattern that such reaction shows and the absence of loss aversion.