11 resultados para Contact lens, Compliance, Microbial keratitis, Case care

em Universidad de Alicante


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To report the successful outcome obtained after fitting a new hybrid contact lens in a cornea with an area of donor-host misalignment and significant levels of irregular astigmatism after penetrating keratoplasty (PKP). Materials and methods: A 41-year-old female with bilateral asymmetric keratoconus underwent PKP in her left eye due to the advanced status of the disease. One year after surgery, the patient referred a poor visual acuity and quality in this eye. The fitting of different types of rigid gas permeable contact lenses was performed, but with an unsuccessful outcome due to contact lens stability problems and uncomfortable wear. Scheimpflug imaging evaluation revealed that a donor-host misalignment was present at the nasal area. Contact lens fitting with a reverse geometry hybrid contact lens (Clearkone, SynergEyes Carlsbad) was then fitted. Visual, refractive, and ocular aberrometric outcomes were evaluated during a 1-year period after the fitting. Results: Uncorrected distance visual acuity improved from a prefitting value of 20/200 to a best corrected postfitting value of 20/20. Prefitting manifest refraction was +5.00 sphere and -5.50 cylinder at 75°, with a corrected distance visual acuity of 20/30. Higher order root mean square (RMS) for a 5 mm pupil changed from a prefitting value of 6.83 µm to a postfitting value of 1.57 µm (5 mm pupil). The contact lens wearing was referred as comfortable, with no anterior segment alterations. Conclusion: The SynergEyes Clearkone contact lens seems to be another potentially useful option for the visual rehabilitation after PKP, especially in cases of donor-host misalignment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To report a very successful outcome obtained with the fitting of a new-generation hybrid contact lens of reverse geometry in a thin cornea with extreme irregularity due to the presence of a central island after unsuccessful myopic excimer laser refractive surgery. Methods: A 32-year-old man attended to our clinic complaining of very poor vision in his right eye after bilateral laser in situ keratomileusis (treatment or surgery) for myopia correction and some additional retreatments afterward. After a comprehensive ocular evaluation, contact lens fitting with a reverse geometry hybrid contact lens (SynergEyes PS, SynergEyes, Carlsbad, CA) was proposed as a solution for this case. Visual, refractive, and ocular aberrometric outcomes with the contact lens were evaluated. Results: Distance visual acuity improved from a prefitting uncorrected value of 20/200 to a postfitting corrected value of 20/16. Prefitting manifest refraction was +6.00 sphere and −3.00 cylinder at 70°, with a corrected distance visual acuity of 20/40. Higher order root mean square for a 5-mm pupil changed from a prefitting value of 1.45 to 0.34 µm with the contact lens. The contact lens wearing was reported as comfortable, and the patient was very satisfied with this solution. Conclusions: The SynergEyes PS contact lens seems to be an excellent option for the visual rehabilitation of corneas with extreme irregularity after myopic excimer laser surgery, minimizing the level of higher order aberrations and providing an excellent visual outcome.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This case report reports the visual rehabilitation obtained with the fitting of a new design of full scleral contact lens (ICD 16.5 contact lens, Paragon Vision Sciences, distributed by Lenticon, Madrid, Spain) in a cornea with advanced keratoconus and previous implantation of intracorneal ring segment with a very limited effect. This eye had a refraction of –3.00 × 55° cylinder, providing a visual acuity of 0.5 LogMAR. The topographic pattern was very irregular with the presence of a significant central protrusion and a significant central corneal thinning. Some previous unsuccessful fittings have been performed with corneal and corneal-scleral lenses. A comfortable wearing was achieved with a fully scleral contact lens of 4600 μm of sagittal height, optical power of –11.25 D, and providing an apical clearance of 196 μm. A visual acuity of 0.0 LogMAR combined with a relevant aberrometric improvement was achieved with this contact lens. The patient was completely satisfied with the fitting. The result was maintained during 1 year after the fitting. Full scleral lenses are then able to provide comfortable wear and a significant increase in visual acuity combined with a significant improvement in the visual quality in eyes with advanced keratoconus.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We describe a case report of a patient that was implanted with a posterior chamber phakic intraocular lens (Phakic Refractive Lens, PRL) for the correction of moderate myopia and who developed postoperatively a fixed mydriasis compatible with an Urrets-Zavalia Syndrome (UZS). Specifically, a sudden acute increase of IOP in the left eye was observed in the immediate postoperative period. After IOP stabilization, the refractive result was good, but a fixed and mydriatic pupil appeared. This condition led the patient to experience visual discomfort, halos, and glare associated with high levels of higher-order aberrations in spite of the good visual result. A tinted-contact lens was fitted in order to minimize those symptoms. The UZS should be considered as a possible complication after implantation of posterior chamber phakic intraocular lenses.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: The aim was to evaluate the visual performance achieved with a new multifocal hybrid contact lens and to compare it with that obtained with two other currently available multifocal soft contact lenses. Methods: This pilot prospective comparative study comprised a total of 16 presbyopic eyes of eight patients ranging in age from 43 to 58 years. All patients were fitted with three different models of multifocal contact lens: Duette multifocal (SynergEyes), Air Optix AQUA multifocal (Alcon) and Biofinity multifocal (CooperVision). Fittings were performed randomly in each patient according to a random number sequence, with a wash-out period between fittings of seven days. At two weeks post-fitting, visual, photopic contrast sensitivity and ocular aberrometry were evaluated. Results: No statistically significant differences were found in distance and near visual acuity achieved with the three different types of multifocal contact lens (p ≥ 0.05). Likewise, no significant differences between lenses were found in the monocular and binocular defocus curve (p ≥ 0.10). Concerning contrast sensitivity, better monocular contrast sensitivities for 6, 12 and 18 cycles per degree were found with the Duette and Air Optix multifocal compared to Biofinity (p = 0.02). Binocularly, differences between lenses were not significant (p ≥ 0.27). Furthermore, trefoil aberration was significantly higher with Biofinity multifocal (p < 0.01) and Air Optix (p = 0.01) multifocal compared to Duette. Conclusions: The Duette multifocal hybrid contact lens seems to provide similar visual quality outcomes in presbyopic patients with low corneal astigmatism, when compared with other soft multifocal contact lenses. This preliminary result should be confirmed in studies with larger samples.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To define a range of normality for the vectorial parameters Ocular Residual Astigmatism (ORA) and topography disparity (TD) and to evaluate their relationship with visual, refractive, anterior and posterior corneal curvature, pachymetric and corneal volume data in normal healthy eyes. Methods: This study comprised a total of 101 consecutive normal healthy eyes of 101 patients ranging in age from 15 to 64 years old. In all cases, a complete corneal analysis was performed using a Scheimpflug photography-based topography system (Pentacam system Oculus Optikgeräte GmbH). Anterior corneal topographic data were imported from the Pentacam system to the iASSORT software (ASSORT Pty. Ltd.), which allowed the calculation of the ocular residual astigmatism (ORA) and topography disparity (TD). Linear regression analysis was used for obtaining a linear expression relating ORA and posterior corneal astigmatism (PCA). Results: Mean magnitude of ORA was 0.79 D (SD: 0.43), with a normality range from 0 to 1.63 D. 90 eyes (89.1%) showed against-the-rule ORA. A weak although statistically significant correlation was found between the magnitudes of posterior corneal astigmatism and ORA (r = 0.34, p < 0.01). Regression analysis showed the presence of a linear relationship between these two variables, although with a very limited predictability (R2: 0.08). Mean magnitude of TD was 0.89 D (SD: 0.50), with a normality range from 0 to 1.87 D. Conclusion: The magnitude of the vector parameters ORA and TD is lower than 1.9 D in the healthy human eye.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundamentos: El elevado número de personas que trabajando con ordenador utiliza lentes de contacto plantea la cuestión sobre si la suma de estos dos factores de riesgo para la salud visual puede originar un agravamiento del Síndrome Visual Informático. El objetivo de esta revisión es sintetizar el conocimiento científico sobre las alteraciones oculares y visuales relacionadas con la exposición a ordenador en usuarios de lentes de contacto. Métodos: Revisión de artículos científicos (2003-2013) en español e inglés, realizando una búsqueda bibliográfica, en Medline a través de PubMed y en Scopus. Resultados: La búsqueda inicial aportó 114 trabajos, después de aplicar criterios de inclusión/exclusión se incluyeron seis artículos. Todos ellos ponen de manifiesto que las alteraciones al utilizar el ordenador son más frecuentes en las personas usuarias de lentes de contacto, con prevalencias que oscilan de 95,0% al 16,9% que en las que no utilizan lentes de contacto, cuya prevalencia va del 57,5% al 9,9% y con una probabilidad cuatro veces mayor de padecer ojo seco [OR: 4,07 (IC 95%: 3,52-4,71)]. Conclusiones: Las personas usuarias de ordenador padecen más alteraciones oculares y visuales cuando además son usuarias de lentes de contacto, pero los estudios son escasos y poco contundentes. Se precisan nuevas investigaciones que analicen la influencia según los tipos de lentes y sus condiciones de uso, tanto en la sintomatología como en la calidad de la lágrima y la superficie ocular. Las lentes de hidrogel de silicona son las que se asocian a mayor confort.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To evaluate and characterize the clinical profile of young asymptomatic or minimally symptomatic patients without diagnosis of dry eye but showing signs compatible with dry eye syndrome (DES). Methods: Prospective study including a total of 50 consecutive subjects with ages ranging from 18 to 40 years that were identified as asymptomatic or minimally symptomatic by means of the Ocular Surface Disease Index (OSDI) (score of <22). In all patients, a complete battery of tests for the diagnosis of DES was performed including the evaluation of the tear film break-up time (TFBUT), the level of corneal and conjunctival staining, and the eyelid and Meibomian morphology. Results: The OSDI score was significantly higher in women than in men (median: 12.5 vs. 5.3, P=0.01). Low grades of ocular surface staining, dysfunction of Meibomian gland expression, and alteration of quality of Meibomian secretions were observed in 56%, 58%, and 84% of eyes, respectively. More eyes with some dysfunction of Meibomian gland expressibility had a TFBUT less than 5 sec (P=0.033). A statistically significant difference in the OSDI score was found between patients with and without systemic allergies (P=0.036) and between male and female (P=0.01). Likewise, the OSDI score was significantly higher in those women wearing contact lenses compared with those not wearing them (P=0.012). Conclusions: Asymptomatic or minimally symptomatic young subjects may present low grades of clinical signs compatible with DES, with a trend to more symptomatology in women and allergic patients. These outcomes should be confirmed in future studies with larger samples.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The purpose of this quasi-experimental study was to assess levels of compliance with the intervention bundles contained in a clinical pathway used in the treatment of patients with severe sepsis and septic shock, and to analyze the pathway’s impact on survival and duration of hospital stays. We used data on 125 patients in an Intensive Care Unit, divided into a control group (N=84) and an intervention group (N=41). Levels of compliance increased from 13.1% to 29.3% in 5 resuscitation bundle interventions and from 14.3% to 22% in 3 monitoring bundle interventions. In-hospital mortality at 28 days decreased by 11.2% and the duration of hospital stay was reduced by 5 days. Although compliance was low, the intervention enhanced adherence to the instructions given in the clinical pathway and we observed a decline in mortality at 28 days and shorter hospital stays.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this study, a digital CMOS camera was calibrated for use as a non-contact colorimeter for measuring the color of granite artworks. The low chroma values of the granite, which yield similar stimulation of the three color channels of the camera, proved to be the most challenging aspect of the task. The appropriate parameters for converting the device-dependent RGB color space into a device-independent color space were established. For this purpose, the color of a large number of Munsell samples (corresponding to the previously defined color gamut of granite) was measured with a digital camera and with a spectrophotometer (reference instrument). The color data were then compared using the CIELAB color formulae. The best correlations between measurements were obtained when the camera works to 10-bits and the spectrophotometric measures in SCI mode. Finally, the calibrated instrument was used successfully to measure the color of six commercial varieties of Spanish granite.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background: Despite the progress made on policies and programmes to strengthen primary health care teams’ response to Intimate Partner Violence, the literature shows that encounters between women exposed to IPV and health-care providers are not always satisfactory, and a number of barriers that prevent individual health-care providers from responding to IPV have been identified. We carried out a realist case study, for which we developed and tested a programme theory that seeks to explain how, why and under which circumstances a primary health care team in Spain learned to respond to IPV. Methods: A realist case study design was chosen to allow for an in-depth exploration of the linkages between context, intervention, mechanisms and outcomes as they happen in their natural setting. The first author collected data at the primary health care center La Virgen (pseudonym) through the review of documents, observation and interviews with health systems’ managers, team members, women patients, and members of external services. The quality of the IPV case management was assessed with the PREMIS tool. Results: This study found that the health care team at La Virgen has managed 1) to engage a number of staff members in actively responding to IPV, 2) to establish good coordination, mutual support and continuous learning processes related to IPV, 3) to establish adequate internal referrals within La Virgen, and 4) to establish good coordination and referral systems with other services. Team and individual level factors have triggered the capacity and interest in creating spaces for team leaning, team work and therapeutic responses to IPV in La Virgen, although individual motivation strongly affected this mechanism. Regional interventions did not trigger individual and/ or team responses but legitimated the workings of motivated professionals. Conclusions: The primary health care team of La Virgen is involved in a continuous learning process, even as participation in the process varies between professionals. This process has been supported, but not caused, by a favourable policy for integration of a health care response to IPV. Specific contextual factors of La Virgen facilitated the uptake of the policy. To some extent, the performance of La Virgen has the potential to shape the IPV learning processes of other primary health care teams in Murcia.