5 resultados para Calculated based on Forel-Ule scale, FU21
em Universidad de Alicante
Resumo:
Composites consisting of polyaniline (PANI) coatings inside the microporosity of an activated carbon fibre (ACF) were prepared by electrochemical and chemical methods. Electrochemical characterization of both composites points out that the electrodes with polyaniline show a higher capacitance than the pristine porous carbon electrode. These materials have been used to develop an asymmetric capacitor based on activated carbon (AC) as negative electrode and an ACF–PANI composite as positive electrode in H2SO4 solution as electrolyte. The presence of a thin layer of polyaniline inside the porosity of the activated carbon fibres avoids the oxidation of the carbon material and the oxygen evolution reaction is produced at more positive potentials. This capacitor was tested in a maximum cell voltage of 1.6 V and exhibited high energy densities, calculated for the unpackaged active materials, with values of 20 W h kg−1 and power densities of 2.1 kW kg−1 with excellent cycle lifetime (90% during the first 1000 cycles) and high coulombic efficiency.
Resumo:
In this paper a new technique for partial product reduction based on the use of look-up tables for efficient processing is presented. We describe how to construct counter devices with pre-calculated data and their subsequent integration into the whole operation. The development of reduction trees organizations for this kind of devices uses the inherent integration benefits of computer memories and offers an alternative implementation to classic operation methods. Therefore, in our experiments we compare our implementation model with CMOS technology model in homogeneous terms.
Resumo:
Purpose: To analyze and define the possible errors that may be introduced in keratoconus classification when the keratometric corneal power is used in such classification. Materials and methods: Retrospective study including a total of 44 keratoconus eyes. A comprehensive ophthalmologic examination was performed in all cases, which included a corneal analysis with the Pentacam system (Oculus). Classical keratometric corneal power (Pk), Gaussian corneal power (Pc Gauss), True Net Power (TNP) (Gaussian power neglecting the corneal thickness effect), and an adjusted keratometric corneal power (Pkadj) (keratometric power considering a variable keratometric index) were calculated. All cases included in the study were classified according to five different classification systems: Alió-Shabayek, Amsler-Krumeich, Rabinowitz-McDonnell, collaborative longitudinal evaluation of keratoconus (CLEK), and McMahon. Results: When Pk and Pkadj were compared, differences in the type of grading of keratoconus cases was found in 13.6% of eyes when the Alió-Shabayek or the Amsler-Krumeich systems were used. Likewise, grading differences were observed in 22.7% of eyes with the Rabinowitz-McDonnell and McMahon classification systems and in 31.8% of eyes with the CLEK classification system. All reclassified cases using Pkadj were done in a less severe stage, indicating that the use of Pk may lead to the classification of a cornea as keratoconus, being normal. In general, the results obtained using Pkadj, Pc Gauss or the TNP were equivalent. Differences between Pkadj and Pc Gauss were within ± 0.7D. Conclusion: The use of classical keratometric corneal power may lead to incorrect grading of the severity of keratoconus, with a trend to a more severe grading.
Resumo:
Determination of reliable solute transport parameters is an essential aspect for the characterization of the mechanisms and processes involved in solute transport (e.g., pesticides, fertilizers, contaminants) through the unsaturated zone. A rapid inexpensive method to estimate the dispersivity parameter at the field scale is presented herein. It is based on the quantification by the X-ray fluorescence solid-state technique of total bromine in soil, along with an inverse numerical modeling approach. The results show that this methodology is a good alternative to the classic Br− determination in soil water by ion chromatography. A good agreement between the observed and simulated total soil Br is reported. The results highlight the potential applicability of both combined techniques to infer readily solute transport parameters under field conditions.
Resumo:
Automated human behaviour analysis has been, and still remains, a challenging problem. It has been dealt from different points of views: from primitive actions to human interaction recognition. This paper is focused on trajectory analysis which allows a simple high level understanding of complex human behaviour. It is proposed a novel representation method of trajectory data, called Activity Description Vector (ADV) based on the number of occurrences of a person is in a specific point of the scenario and the local movements that perform in it. The ADV is calculated for each cell of the scenario in which it is spatially sampled obtaining a cue for different clustering methods. The ADV representation has been tested as the input of several classic classifiers and compared to other approaches using CAVIAR dataset sequences obtaining great accuracy in the recognition of the behaviour of people in a Shopping Centre.