7 resultados para Built in 1973 Maison

em Universidad de Alicante


Relevância:

100.00% 100.00%

Publicador:

Resumo:

If one has a distribution of words (SLUNs or CLUNS) in a text written in language L(MT), and is adjusted one of the mathematical expressions of distribution that exists in the mathematical literature, some parameter of the elected expression it can be considered as a measure of the diversity. But because the adjustment is not always perfect as usual measure; it is preferable to select an index that doesn't postulate a regularity of distribution expressible for a simple formula. The problem can be approachable statistically, without having special interest for the organization of the text. It can serve as index any monotonous function that has a minimum value when all their elements belong to the same class, that is to say, all the individuals belong to oneself symbol, and a maximum value when each element belongs to a different class, that is to say, each individual is of a different symbol. It should also gather certain conditions like they are: to be not very sensitive to the extension of the text and being invariant to certain number of operations of selection in the text. These operations can be theoretically random. The expressions that offer more advantages are those coming from the theory of the information of Shannon-Weaver. Based on them, the authors develop a theoretical study for indexes of diversity to be applied in texts built in modeling language L(MT), although anything impedes that they can be applied to texts written in natural languages.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

From the late seventeenth to early nineteenth centuries, many religious temples have been built in the province of Alicante (south east of Spain) with brick domes as their main characteristic feature. Often, the limited data available about these remarkable constructions make rehabilitation interventions become into real research projects, with a high value for their historic conservation over time. The aim of this paper is to show a detailed refurbishment analysis of a religious temple built in 1778, showing the need of preservation of historic buildings as a part of the architectural heritage by establishing a common pattern of materials, geometry and constructive systems, specifically in their domes. In most cases, there was not an architectural project for the construction, that is why the analysis of any documentary and archival sources available is essential to find different ways to proceed on the use and maintenance of these religious buildings.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In order to equip architecture students with ambitious detail designing ability, related courses of the architecture programs should deal with subjects which are rather rare and unusual for real life practices in order to prevent students copying standard details. In 2015 an innovative project brief has been given to architecture students of Istanbul Technical University. The scenario given in the brief is to design a research station for the first group of Turkish scientist, to be built in one of the coldest and most arid regions on earth; the Antarctica. The performance requirements given in the brief were determined to prevent the students from copying details from any kind of resources as the total number of details generated in real life for those conditions are very limited and specific. The method used has demonstrated a great success and creative detail solutions were generated by the students. In the paper, the innovative coursework brief for bettering the detail design ability of architecture students is explained and the output of the studio is presented.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

According to the importance of rehabilitation and recovery of Architectural Heritage in the live of people, this paper is aimed to strengthen the traditional methods of stone vaults calculation taking advantage of the technological characteristics of the powerful program ANSYS Workbench. As an example of this, it could find out the possible pathologies that could arise during the construction history of the building. To limit this research, the upper vault of the main chapel of the Santiago parish church in Orihuela -Alicante- is selected as a reference which is a Jeronimo Quijano´s important building work in the XVI century in the Renaissance. Moreover, it is an innovative stone masonry vault that consists of 8 double intercrossed arches with each other and braced by severies. During the seventeenth century there was a lantern in the central cap and it is unknown why it was removed. Its construction could justify the original constructive solution with intercrossed arches that freed the center to create a more enlightened and comfortable presbytery. By similarity with other Quijano’s works, it is considered a small lantern drilling the central spherical cap. It is proposed to carry out a comparative study of it with different architectural solutions from the same period and based on several common parameters such as: a vault of square plant with spherical surround, intercrossed arches, a possible lantern, the dimension of the permitted space, similar states of loads and compact limestone masonry. The three solutions are mainly differentiated by their size and the type of lantern and its comparison lets us know which one is the most resistant and stable. The other two building works maintain some connection with the Quijano's professional scope. It has selected the particular case of the Communion chapel of the Basilica in Elche (a large prismatic lantern with a large cylindrical drum that starts from the own arches and an upper hemispherical dome), for its conservation, its proximity to Orihuela and its implementation during the century XVIII. Finally, a significant Dome Spanish Renaissance complete the selection: a cross vault of the Benavides Chapel of the Saint Francisco Convent in Baeza - Jaén-, designed by Andres of Vandelvira in the sixteenth century (a large hemispherical dome that starts from the own arcs). To simplify the calculation and standardize the work that have to be contrasted, all of them were considered with some similar characteristics: 30 cm constant thickness, the intercrossed arches were specifically analyzed and had identical loads, Young's modulus and Poisson's ratio. Regarding the calculation solutions, in general terms, the compressive stresses predominate, influencing on it the joint collaboration of the filling material on the vault, the vault itself, the thick side walls, the buttresses and the top cover weight . In addition, the three solutions are suitable, being the Orihuela one the safest and the Baeza one the riskiest for its large dimensions. Thus, the idea of intercrossed arches with suitable thickness would allow carry out the heaviest lantern and this would confirm it as a Renaissance architectural typology built in stone.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

More than a hundred public air-raid shelters were constructed beneath Alicante during the Spanish Civil war. Their architectural uniqueness and humanitarian purpose render these shelters a tangible testament to our recent history. The Alicante Municipal Archives hold reports written by technicians who inspected the shelters in the 1940s, which were subsequently included in the Special Plan for public shelters in 1953. Half a century later, in 2003, information on the air-raid shelters was included in another Special Plan aimed at protecting Alicante’s archaeological heritage. Thanks to the work of the Municipal Heritage Conservation unit (COPHIAM) and the Special Protection Plan for Urban Archaeology (PEPA), the exact or approximate locations were identified for almost 90% of the shelters known to have existed. This paper describes interventions in two of these architectural spaces using advanced museology techniques. The first concerns air-raid shelter R46, located in the Plaza del Dr. Balmis in the city centre. This was built in 1938, and is rectangular with two entrances. The second is air-raid shelter R31, located in the Plaza Séneca.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

After the construction of the San Carlos bastion in Alicante in the final decade of the seventeenth century, and the great trench which the English built around the district of San Francisco during their years of dominance in the War of Succession, the waters of the San Blas gully caused serious damage to these fortifications of the city and to the trade buildings of the port. In 1772, the diversion canal was built. It was designed to divert the riverbed of the gully and send the waters directly to the sea. The project had been initially designed by the Engineer General, Jorge Próspero de Verboom in 1721. This unique work of engineering had some defects, principally in the breakwater which prevented the waters from flowing down the former river course. On several occasions, the water returned to its original riverbed due to the weakness of the breakwater, the narrowness of the channel’s bed and its lack of regularisation, causing serious damage to the bastion, the Babel-facing façade, the traders’ warehouses and other buildings. This study describes the project that the military engineer Leandro Badarán carried out in 1794 in order to technically improve this canal and examines his report on the state of the fortifications. Similar works built in Spain are also explained. It also analyses the repeated disputes between the war department and the port throughout these years over finding a technical solution to the problem.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Integrity assurance of configuration data has a significant impact on microcontroller-based systems reliability. This is especially true when running applications driven by events which behavior is tightly coupled to this kind of data. This work proposes a new hybrid technique that combines hardware and software resources for detecting and recovering soft-errors in system configuration data. Our approach is based on the utilization of a common built-in microcontroller resource (timer) that works jointly with a software-based technique, which is responsible to periodically refresh the configuration data. The experiments demonstrate that non-destructive single event effects can be effectively mitigated with reduced overheads. Results show an important increase in fault coverage for SEUs and SETs, about one order of magnitude.