7 resultados para 3 d]pyrimidine
em Universidad de Alicante
Resumo:
This paper shows the results of an experimental analysis on the bell tower of “Chiesa della Maddalena” (Mola di Bari, Italy), to better understand the structural behavior of slender masonry structures. The research aims to calibrate a numerical model by means of the Operational Modal Analysis (OMA) method. In this way realistic conclusions about the dynamic behavior of the structure are obtained. The choice of using an OMA derives from the necessity to know the modal parameters of a structure with a non-destructive testing, especially in case of cultural-historical value structures. Therefore by means of an easy and accurate process, it is possible to acquire in-situ environmental vibrations. The data collected are very important to estimate the mode shapes, the natural frequencies and the damping ratios of the structure. To analyze the data obtained from the monitoring, the Peak Picking method has been applied to the Fast Fourier Transforms (FFT) of the signals in order to identify the values of the effective natural frequencies and damping factors of the structure. The main frequencies and the damping ratios have been determined from measurements at some relevant locations. The responses have been then extrapolated and extended to the entire tower through a 3-D Finite Element Model. In this way, knowing the modes of vibration, it has been possible to understand the overall dynamic behavior of the structure.
Resumo:
One option to optimize carbon materials for supercapacitor applications is the generation of surface functional groups that contribute to the pseudocapacitance without losing the designed physical properties. This requires suitable functionalization techniques able to selectively introduce a given amount of electroactive oxygen groups. In this work, the influence of the chemical and electrochemical oxidation methods, on the chemical and physical properties of a zeolite templated carbon (ZTC), as a model carbon material, have been studied and compared. Although both oxidation methods generally produce a loss of the original ZTC physical properties with increasing amount of oxidation, the electrochemical method shows much better controllability and, unlike chemical treatments, enables the generation of a large number of oxygen groups (O = 11000- 3300 μmol/g), with a higher proportion of active functionalities, while retaining a high surface area (ranging between 1900-3500 m2/g), a high microporosity and an ordered 3-D structure.
Resumo:
Zeolite templated carbon (ZTC) was electrochemically oxidized under various conditions, and its chemistry and structural evolution were compared to those produced by conventional chemical oxidation. In both oxidation methods, a general loss of the original structure regularity and high surface area was observed with increasing amount of oxidation. However, the electrochemical method showed much better controllability and enabled the generation of a large number of oxygen functional groups while retaining the original structure of the ZTC. Unlike chemical treatments, highly microporous carbons with an ordered 3-D structure, high surface area (ranging between 1900 and 3500 m2/g) and a large number of oxygen groups (O = 11,000–3300 μmol/g), have been prepared by the electrochemical method. Some insights into the electrooxidation mechanism of carbon materials are proposed from the obtained polarization curves, using ZTC as a model carbon material.
Resumo:
Se ha realizado un modelo geológico en 3D de la porción NO de la Cuenca del Bajo Segura, por ser esta la que mostraba una menor complicación geológica. La cuenca se ha dividido en 7 sintemas (nombrados Ab,M1, M2, P1, P2, Pc y Q) y se ha utilizado como base de la cuenca el techo de la Formación Calizas de Las Ventanas (Ve). La construcción del modelo 3D permite un mejor conocimiento geológico de la cuenca. El modelo apunta a una mayor complicación tectónica de lo supuesto en un principio.
Resumo:
Objective: To evaluate two cases of intermittent exotropia (IX(T)) treated by vision therapy the efficacy of the treatment by complementing the clinical examination with a 3-D video-oculography to register and to evidence the potential applicability of this technology for such purpose. Methods: We report the binocular alignment changes occurring after vision therapy in a woman of 36 years with an IX(T) of 25 prism diopters (Δ) at far and 18 Δ at near and a child of 10 years with 8 Δ of IX(T) in primary position associated to 6 Δ of left eye hypotropia. Both patients presented good visual acuity with correction in both eyes. Instability of ocular deviation was evident by VOG analysis, revealing also the presence of vertical and torsional components. Binocular vision therapy was prescribed and performed including different types of vergence, accommodation, and consciousness of diplopia training. Results: After therapy, excellent ranges of fusional vergence and a “to-the-nose” near point of convergence were obtained. The 3-D VOG examination (Sensoro Motoric Instruments, Teltow, Germany) confirmed the compensation of the deviation with a high level of stability of binocular alignment. Significant improvement could be observed after therapy in the vertical and torsional components that were found to become more stable. Patients were very satisfied with the outcome obtained by vision therapy. Conclusion: 3D-VOG is a useful technique for providing an objective register of the compensation of the ocular deviation and the stability of the binocular alignment achieved after vision therapy in cases of IX(T), providing a detailed analysis of vertical and torsional improvements.
Resumo:
Objetivo: Evaluar la eficacia del tratamiento en 3 casos de exotropia intermitente (XT(i)) mediante ejercicios de terapia visual, completando la exploración clínica con Videooculografia-30 y evidenciar la potencial aplicabilidad de esta tecnología para dicho propósito. Métodos: Exponemos los cambios ocurridos tras ejercicios de terapia visual en una mujer de 36 años con XT(i) de -25 dioptrías prismáticas (dp) de lejos y 18 dp de cerca; Un niño de 10 años de edad con 8 dp de XT(i) en posición primaria, asociados a +6 dp de hipotropia izquierda; y un hombre de 63 años con XT(i) de 6 dp en posición primaria asociada a +7 dp de hipertropia derecha. Todos los pacientes presentaron buena agudeza visual corregida en ambos ojos. La inestabilidad de la desviación ocular se evidenció mediante análisis de VOG-30, revelando la presencia de components verticales y torsionales. Se realizaron ejercicios de terapia visual, incluyendo diferentes tipos de ejercicios de vergencias, acomodación y percepción de la diplopía. Resultados: Tras la terapia visual se obtuvieron excelentes rangos de vergencias fusionales y de punto próximo de convergencia («hasta la nariz»). El examen mediante VOG-3D (Sensoro Motoric lnstruments, Teltow, Germany) confirmó la compensación de la desviación con estabilidad del alineamiento ocular. Se observó una significativa mejora después de la terapia en los components verticals y torsionales, lo cuales se hicieron más estables. Los pacientes se mostraron muy satisfechos de los resultados obtenidos. Conclusión: La VOG-3D es una técnica útil para dotamos de un método objetivo de registro de la compensación y estabilidad de la desviación ocular después de realizar ejercicios de terapia visual en casos de XT(i), ofreciéndonos un detallado análisis de la mejoría de los components verticales y torsionales.
Resumo:
Purpose: The aim of this study was to analyze theoretically the errors in the central corneal power calculation in eyes with keratoconus when a keratometric index (nk) is used and to clinically confirm the errors induced by this approach. Methods: Differences (DPc) between central corneal power estimation with the classical nk (Pk) and with the Gaussian equation (PGauss c ) in eyes with keratoconus were simulated and evaluated theoretically, considering the potential range of variation of the central radius of curvature of the anterior (r1c) and posterior (r2c) corneal surfaces. Further, these differences were also studied in a clinical sample including 44 keratoconic eyes (27 patients, age range: 14–73 years). The clinical agreement between Pk and PGauss c (true net power) obtained with a Scheimpflug photography–based topographer was evaluated in such eyes. Results: For nk = 1.3375, an overestimation was observed in most cases in the theoretical simulations, with DPc ranging from an underestimation of 20.1 diopters (D) (r1c = 7.9 mm and r2c = 8.2 mm) to an overestimation of 4.3 D (r1c = 4.7 mm and r2c = 3.1 mm). Clinically, Pk always overestimated the PGauss c given by the topography system in a range between 0.5 and 2.5 D (P , 0.01). The mean clinical DPc was 1.48 D, with limits of agreement of 0.71 and 2.25 D. A very strong statistically significant correlation was found between DPc and r2c (r = 20.93, P , 0.01). Conclusions: The use of a single value for nk for the calculation of corneal power is imprecise in keratoconus and can lead to significant clinical errors.