20 resultados para validation study

em University of Queensland eSpace - Australia


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Social Vulnerability Scale (SVS), an informant-report of social vulnerability for older adults, was piloted in a sample of 167 undergraduate students (63 male, 104 female) from the University of Queensland. Participants aged 18 - 53 (M = 25.53 years, SD = 7.83 years) completed the SVS by rating a relative or friend aged ≥50 years (M = 71.65 years, SD = 12.49 years): either someone with memory problems, stroke, dementia, or other neurological condition (n = 85); or a healthy older adult (n = 82). Excellent internal consistency and test - retest reliability were demonstrated, and the SVS effectively differentiated healthy older adults from those with a neurological condition based on proxy ratings of social vulnerability. The SVS is a potentially useful adjunct measure of older adults' capacity to reside independently. 1 *For information on using the Social Vulnerability Scale, email d.pinsker@psy.uq.edu.au or stone@psy.uq.edu.au

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: The Functional Capacity Index (FCI) was designed to predict physical function 12 months after injury. We report a validation study of the FCI. Methods: This was a consecutive case series registered in the Queensland Trauma Registry who consented to the prospective 12-month telephone-administered follow-up study. FCI scores measured at 12 months were compared with those originally predicted. Results: Complete Abbreviated Injury Scale score information was available for 617 individuals, of whom 587 (95%) could be assigned at least one FCI score (range, 1-17). Agreement between the largest predicted FCI and observed FCI score was poor (kappa = 0.05; 95% confidence interval, 0.00-0.10) and explained only 1% of the variability in observed FCI. Using an encompassing model that included all FCI assignments, agreement remained poor (kappa = 0.05; 95% confidence interval, -0.02-0.12), and the model explained only 9% of the variability in observed FCI. Conclusion: The predicted functional capacity poorly agrees with actual functional outcomes. Further research should consider including other (noninjury) explanatory factors in predicting FCI at 12 months.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Orthotopic liver retransplantation (re-OLT) is highly controversial. The objectives of this study were to determine the validity of a recently developed United Network for Organ Sharing (UNOS) multivariate model using an independent cohort of patients undergoing re-OLT outside the United States, to determine whether incorporation of other variables that were incomplete in the UNOS registry would provide additional prognostic information, to develop new models combining data sets from both cohorts, and to evaluate the validity of the model for end-stage liver disease (MELD) in patients undergoing re-OLT. Two hundred eighty-one adult patients undergoing re-OLT (between 1986 and 1999) at 6 foreign transplant centers comprised the validation cohort. We found good agreement between actual survival and predicted survival in the validation cohort; 1-year patient survival rates in the low-, intermediate-, and high-risk groups (as assigned by the original UNOS model) were 72%, 68%, and 36%, respectively (P < .0001). In the patients for whom the international normalized ratio (INR) of prothrombin time was available, MELD correlated with outcome following re-OLT; the median MELD scores for patients surviving at least 90 days compared with those dying within 90 days were 20.75 versus 25.9, respectively (P = .004). Utilizing both patient cohorts (n = 979), a new model, based on recipient age, total serum bilirubin, creatinine, and interval to re-OLT, was constructed (whole model χ(2) = 105, P < .0001). Using the c-statistic with 30-day, 90-day, 1-year, and 3-year mortality as the end points, the area under the receiver operating characteristic (ROC) curves for 4 different models were compared. In conclusion, prospective validation and use of these models as adjuncts to clinical decision making in the management of patients being considered for re-OLT are warranted.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Reliability or validity studies are important for the evaluation of measurement error in dietary assessment methods. An approach to validation known as the method of triads uses triangulation techniques to calculate the validity coefficient of a food-frequency questionnaire (FFQ). Objective: To assess the validity of an FFQ estimates of carotenoid and vitamin E intake against serum biomarker measurements and weighed food records (WFRs), by applying the method of triads. Design: The study population was a sub-sample of adult participants in a randomised controlled trial of beta-carotene and sunscreen in the prevention of skin cancer. Dietary intake was assessed by a self-administered FFQ and a WFR. Nonfasting blood samples were collected and plasma analysed for five carotenoids (alpha-carotene, beta-carotene, beta-cryptoxanthin, lutein, lycopene) and vitamin E. Correlation coefficients were calculated between each of the dietary methods and the validity coefficient was calculated using the method of triads. The 95% confidence intervals for the validity coefficients were estimated using bootstrap sampling. Results: The validity coefficients of the FFQ were highest for alpha-carotene (0.85) and lycopene (0.62), followed by beta- carotene (0.55) and total carotenoids (0.55), while the lowest validity coefficient was for lutein (0.19). The method of triads could not be used for b- cryptoxanthin and vitamin E, as one of the three underlying correlations was negative. Conclusions: Results were similar to other studies of validity using biomarkers and the method of triads. For many dietary factors, the upper limit of the validity coefficients was less than 0.5 and therefore only strong relationships between dietary exposure and disease will be detected.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study aimed to replicate and cross-validate the Rapid Screen of Concussion (RSC) for diagnosing mild TBI (mTBI). One hundred (81 male, 19 female) cases of mTBI and 35 (23 male and 12 female) cases of orthopaedic injuries were tested within 24 hr of injury. Double cross-validation was used to examine whether total RSC scores obtained in the cur-rent sample, generalised to one previously reported. In the new sample, mTBI patients answered fewer orientation questions, recalled fewer words on the learning trial and after a delay, judged fewer sentences in 2 min, and completed fewer symbols in the Digit Symbol Substitution Test than orthopaedic controls. The formulae and cut-offs developed on the original and new samples produced similar sensitivity and overall correct classification rates. Inclusion of the Digit Symbol Substitution Test performance of the new sample improved the sensitivity (80.2%) and specificity (82.6%) in males. It did not improve the correct classification rate in females, which was 89.5% sensitivity and 91.7% specificity before the inclusion of the Digit Symbol Substitution Test. Taken together, these results indicate that a combined score on this 12-min screen yields a measure of level of brain impairment up to 24 hr after mTBI.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aims The aims of this study are to develop and validate a measure to screen for a range of gambling-related cognitions (GRC) in gamblers. Design and participants A total of 968 volunteers were recruited from a community-based population. They were divided randomly into two groups. Principal axis factoring with varimax rotation was performed on group one and confirmatory factor analysis (CFA) was used on group two to confirm the best-fitted solution. Measurements The Gambling Related Cognition Scale (GRCS) was developed for this study and the South Oaks Gambling Screen (SOGS), the Motivation Towards Gambling Scale (MTGS) and the Depression Anxiety Stress Scale (DASS-2 1) were used for validation. Findings Exploratory factor analysis performed using half the sample indicated five factors, which included interpretative control/bias (GRCS-IB), illusion of control (GRCS-IC), predictive control (GRCS-PC), gambling-related expectancies (GRCS-GE) and a perceived inability to stop gambling (GRCS-IS). These accounted for 70% of the total variance. Using the other half of the sample, CFA confirmed that the five-factor solution fitted the data most effectively. Cronbach's alpha coefficients for the factors ranged from 0.77 to 0.91, and 0.93 for the overall scale. Conclusions This paper demonstrated that the 23-item GRCS has good psychometric properties and thus is a useful instrument for identifying GRC among non-clinical gamblers. It provides the first step towards devising/adapting similar tools for problem gamblers as well as developing more specialized instruments to assess particular domains of GRC.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In vitro measurements of skin absorption are an increasingly important aspect of regulatory studies, product support claims, and formulation screening. However, such measurements are significantly affected by skin variability. The purpose of this study was to determine inter- and intralaboratory variation in diffusion cell measurements caused by factors other than skin. This was attained through the use of an artificial (silicone rubber) rate-limiting membrane and the provision of materials including a standard penetrant, methyl paraben (MP), and a minimally prescriptive protocol to each of the 18 participating laboratories. Standardized calculations of MP flux were determined from the data submitted by each laboratory by applying a predefined mathematical model. This was deemed necessary to eliminate any interlaboratory variation caused by different methods of flux calculations. Average fluxes of MP calculated and reported by each laboratory (60 +/- 27 mug cm(-2) h(-1), n = 25, range 27-101) were in agreement with the standardized calculations of MP flux (60 +/- 21 mug cm(-2) h(-1), range 19-120). The coefficient of variation between laboratories was approximately 35% and was manifest as a fourfold difference between the lowest and highest average flux values and a sixfold difference between the lowest and highest individual flux values. Intra-laboratory variation was lower, averaging 10% for five individuals using the same equipment within a single laboratory. Further studies should be performed to clarify the exact components responsible for nonskin-related variability in diffusion cell measurements. It is clear that further developments of in vitro methodologies for measuring skin absorption are required. (C) 2005 Wiley-Liss, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The critical process parameter for mineral separation is the degree of mineral liberation achieved by comminution. The degree of liberation provides an upper limit of efficiency for any physical separation process. The standard approach to measuring mineral liberation uses mineralogical analysis based two-dimensional sections of particles which may be acquired using a scanning electron microscope and back-scatter electron analysis or from an analysis of an image acquired using an optical microscope. Over the last 100 years, mathematical techniques have been developed to use this two dimensional information to infer three-dimensional information about the particles. For mineral processing, a particle that contains more than one mineral (a composite particle) may appear to be liberated (contain only one mineral) when analysed using only its revealed particle section. The mathematical techniques used to interpret three-dimensional information belong, to a branch of mathematics called stereology. However methods to obtain the full mineral liberation distribution of particles from particle sections are relatively new. To verify these adjustment methods, we require an experimental method which can accurately measure both sectional and three dimensional properties. Micro Cone Beam Tomography provides such a method for suitable particles and hence, provides a way to validate methods used to convert two-dimensional measurements to three dimensional estimates. For this study ore particles from a well-characterised sample were subjected to conventional mineralogical analysis (using particle sections) to estimate three-dimensional properties of the particles. A subset of these particles was analysed using a micro-cone beam tomograph. This paper presents a comparison of the three-dimensional properties predicted from measured two-dimensional sections with the measured three-dimensional properties.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The authors measured perceptions of safety climate, motivation, and behavior at 2 time points and linked them to prior and subsequent levels of accidents over a 5-year period. A series of analyses examined the effects of top-down and bottom-up processes operating simultaneously over time. In terms of top-down effects, average levels of safety climate within groups at I point in time predicted subsequent changes in individual safety motivation. Individual safety motivation, in turn, was associated with subsequent changes in self-reported safety behavior. In terms of bottom-up effects, improvements in the average level of safety behavior within groups were associated with a subsequent reduction in accidents at the group level. The results contribute to an understanding of the factors influencing workplace safety and the levels and lags at which these effects operate.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Published birthweight references in Australia do not fully take into account constitutional factors that influence birthweight and therefore may not provide an accurate reference to identify the infant with abnormal growth. Furthermore, studies in other regions that have derived adjusted (customised) birthweight references have applied untested assumptions in the statistical modelling. Aims: To validate the customised birthweight model and to produce a reference set of coefficients for estimating a customised birthweight that may be useful for maternity care in Australia and for future research. Methods: De-identified data were extracted from the clinical database for all births at the Mater Mother's Hospital, Brisbane, Australia, between January 1997 and June 2005. Births with missing data for the variables under study were excluded. In addition the following were excluded: multiple pregnancies, births less than 37 completed week's gestation, stillbirths, and major congenital abnormalities. Multivariate analysis was undertaken. A double cross-validation procedure was used to validate the model. Results: The study of 42 206 births demonstrated that, for statistical purposes, birthweight is normally distributed. Coefficients for the derivation of customised birthweight in an Australian population were developed and the statistical model is demonstrably robust. Conclusions: This study provides empirical data as to the robustness of the model to determine customised birthweight. Further research is required to define where normal physiology ends and pathology begins, and which segments of the population should be included in the construction of a customised birthweight standard.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: In 1992, Frisch et al (Psychol Assess. 1992;4:92- 10 1) developed the Quality of Life Inventory (QOLI) to measure the concept of quality of life (QOL) because it has long been thought to be related to both physical and emotional well-being. However, the psychometric properties of the QOLI in clinical populations are still in debate. The present study examined the factor structure of QOLI and reported its validity and reliability in a clinical sample. Method: Two hundred seventeen patients with anxiety and depressive disorders completed the QOLI and additional questionnaires measuring symptoms (Zung Self-rating Depression Scale, Beck Anxiety Inventory, Fear Questionnaire, Depression Anxiety Stress Scale-Stress) and subjective well-being (Satisfaction With Life Scale) were also used. Results: Exploratory factor analysis via the principal components method, with oblique rotation, revealed a 2-factor structure that accounted for 42.73% of the total variance, and a subsequent confirmatory factor analysis suggested a moderate fit of the data to this model. The 2 factors appeared to describe self-oriented QOL and externally oriented QOL. The Cronbach alpha coefficients were 0.85 for the overall QOLI score, 0.81 for the first factor, and 0.75 for the second factor. Conclusion: Consistent evidence was also found to support the concurrent, discriminant, predictive, and criterion-related validity of the QOLI. (c) 2006 Elsevier Inc. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

There is currently no validated scoring system for quantification of airway secretions in children. A user friendly, valid scoring system of airway secretions during flexible bronchoscopy (FB) would be useful for comparative purposes in clinical medicine and research. The objective of this study was to validate our bronchoscopic secretion (BS) scoring system by examining the relationship between the amount of secretions seen at bronchoscopy with airway cellularity and microbiology. In 106 children undergoing FIB, the relationship of BS grades with bronchocalveolar lavage (BAL) cellularity and infective state (bacterial and viral infections) were examined using receptor operator curves (ROC). BAL was obtained according to European Respiratory Society guidelines; first lavage for microbiology and second lavage for cellularity Area under the ROC was significant for total cell count (TCC) and neutrophil % but not for lymphocyte %. BS grade significantly related to infection positive state (chi(2)(trend) = 5.85, P = 0,016). The area under the ROC for infection positive state versus BS grade was 0.645, 95% Cl 0.527-0.763. The BS scoring system is a valid method for quantifying airway secretions in children undergoing bronchoscopy The system related well to airway cellularity and neutrophilia, as well as to an airway infective state. However, the system is only complementary to cell counts and cultures and cannot replace these laboratory quantification techniques.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Two-dimensional (2-D) strain (epsilon(2-D)) on the basis of speckle tracking is a new technique for strain measurement. This study sought to validate epsilon(2-D) and tissue velocity imaging (TVI)based strain (epsilon(TVI)) with tagged harmonic-phase (HARP) magnetic resonance imaging (MRI). Thirty patients (mean age. 62 +/- 11 years) with known or suspected ischemic heart disease were evaluated. Wall motion (wall motion score index 1.55 +/- 0.46) was assessed by an expert observer. Three apical images were obtained for longitudinal strain (16 segments) and 3 short-axis images for radial and circumferential strain (18 segments). Radial epsilon(TVI) was obtained in the posterior wall. HARP MRI was used to measure principal strain, expressed as maximal length change in each direction. Values for epsilon(2-D), epsilon(TVI), and HARP MRI were comparable for all 3 strain directions and were reduced in dysfunctional segments. The mean difference and correlation between longitudinal epsilon(2-D) and HARP MRI (2.1 +/- 5.5%, r = 0.51, p < 0.001) were similar to those between longitudinal epsilon(TVI), and HARP MRI (1.1 +/- 6.7%, r = 0.40, p < 0.001). The mean difference and correlation were more favorable between radial epsilon(2-D) and HARP MRI (0.4 +/- 10.2%, r = 0.60, p < 0.001) than between radial epsilon(TVI), and HARP MRI (3.4 +/- 10.5%, r = 0.47, p < 0.001). For circumferential strain, the mean difference and correlation between epsilon(2-D) and HARP MRI were 0.7 +/- 5.4% and r = 0.51 (p < 0.001), respectively. In conclusion, the modest correlations of echocardiographic and HARP MRI strain reflect the technical challenges of the 2 techniques. Nonetheless, epsilon(2-D) provides a reliable tool to quantify regional function, with radial measurements being more accurate and feasible than with TVI. Unlike epsilon(TVI), epsilon(2-D) provides circumferential measurements. (c) 2006 Elsevier Inc. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Exercise brachial blood pressure ( BP) predicts mortality, but because of wave reflection, central ( ascending aortic) pressure differs from brachial pressure. Exercise central BP may be clinically important, and a noninvasive means to derive it would be useful. The purpose of this study was to test the validity of a noninvasive technique to derive exercise central BP. Ascending aortic pressure waveforms were recorded using a micromanometer-tipped 6F Millar catheter in 30 patients (56 +/- 9 years; 21 men) undergoing diagnostic coronary angiography. Simultaneous recordings of the derived central pressure waveform were acquired using servocontrolled radial tonometry at rest and during supine cycling. Pulse wave analysis of the direct and derived pressure signals was performed offline (SphygmoCor 7.01). From rest to exercise, mean arterial pressure and heart rate were increased by 20 +/- 10 mm Hg and 15 +/- 7 bpm, respectively, and central systolic BP ranged from 77 to 229 mm Hg. There was good agreement and high correlation between invasive and noninvasive techniques with a mean difference (+/- SD) for central systolic BP of -1.3 +/- 3.2 mm Hg at rest and -4.7 +/- 3.3 mm Hg at peak exercise ( for both r=0.995; P < 0.001). Conversely, systolic BP was significantly higher peripherally than centrally at rest (155 +/- 33 versus 138 +/- 32mm Hg; mean difference, -16.3 +/- 9.4mm Hg) and during exercise (180 +/- 34 versus 164 +/- 33 mm Hg; mean difference, -15.5 +/- 10.4 mm Hg; for both P < 0.001). True myocardial afterload is not reliably estimated by peripheral systolic BP. Radial tonometry and pulse wave analysis is an accurate technique for the noninvasive determination of central BP at rest and during exercise.