15 resultados para protective coatings
em University of Queensland eSpace - Australia
Resumo:
The effect of postcure high energy (gamma), ultraviolet (UV) and thermal treatment on the properties of polyester-melamine clearcoats of a range of compositions has been investigated. Two initial cure conditions were used, of which one was '' optimally '' cured and the other undercured. It was found that postcure treatments, particularly gamma and UV, led to coatings of similar mechanical and thermal properties irrespective of initial cure, although the change in properties on postcure treatment was greater for the under-cured samples. The results were interpreted in terms of the effect of the treatments on the structure of the crosslinked matrices. The study suggests the possibility of the development of a dual-cure process for polyester-melamines, whereby cure optimization and property improvement can be achieved. This could also be used to '' correct '' for small variations in thermal cure levels brought about by adventitious online fluctuations in cure oven conditions.
Resumo:
Background: Observation of the occurrence of protective muscle activity is advocated in assessment of the peripheral nervous system by means of neural provocation tests. However, no studies have yet demonstrated abnormal force generation in a patient population. Objectives: To analyze whether aberrations in shoulder girdle-elevation force during neural tissue provocation testing for the median nerve (NTPTI) can be demonstrated, and whether possible aberrations can be normalized following cervical mobilization. Study Design: A single-blind randomized comparative controlled study. Setting: Laboratory setting annex in a manual therapy teaching practice. Participants: Twenty patients with unilateral or bilateral neurogenic cervicobrachial pain. Methods: During the NTPTI, we used a load cell and electrogoniometer to record continuously the shoulder-girdle elevation force in relation to the available range of elbow extension. Following randomization, we analyzed the immediate treatment effects of a cervical contralateral lateral glide mobilization technique (experimental group) and therapeutic ultrasound (control group). Results: On the involved side, the shoulder-girdle elevation force occur-red earlier, and the amount of force at the end of the test was substantially, though not significantly, greater than that on the uninvolved side at the corresponding range of motion. Together with a significant reduction in pain perception after cervical mobilization, a clear tendency toward normalization of the force curve could be observed, namely, a significant decrease in force generation and a delayed onset. The control group demonstrated no differences. Conclusions: Aberrations in force generation during neural, provocation testing are present in patients with neurogenic pain and can be normalized with appropriate treatment modalities.
Resumo:
The mechanical properties of a range of agglomerates and particulate coatings have been measured using a nanoindenter. The effect of formulation properties such as powder and binder properties on coating hardness is described. An attempt is also made to measure the fracture hardness with the nanoindenter. The use of indentation technology to measure fundamental agglomerate properties is critically analysed. Based on the indentation measurements and standard attrition test results, the coating hardness is found closely related to the attrition rate under standard conditions and can be used to screen different powder/binder formulations. (C) 2002 Elsevier Science B.V All rights reserved.
Resumo:
The persistence of the E7 oncoprotein in transformed cells in human papillomavirus (HPV)-associated cervical cancer provides a tumour-specific antigen to which immunotherapeutic strategies may be directed. Self-replicating RNA (replicon) vaccine vectors derived from the flavivirus Kunjin (KUN) have recently been reported to induce T-cell immunity. Here, we report that inclusion of a CTL epitope of HPV16 E7 protein into a polyepitope encoded by a KUN vector induced E7-directed T-cell responses and protected mice against challenge with an E7-expressing epithelial tumour. We found replicon RNA packaged into virus-like particles to be more effective than naked replicon RNA or plasmid DNA constructed to allow replicon RNA transcription in vivo. Protective immunity was induced although the E7 CTL epitope was subdominant in the context of other CTL epitopes in the polyepitope. The results demonstrate the efficacy of the KUN replicon vector system for inducing protective immunity directed towards a virally encoded human tumour-specific antigen, and for inducing multi-epitopic CTL responses. (C) 2004 Elsevier Inc. All rights reserved.
Resumo:
Using a Radial Guide Field Matching Method, an investigation is performed into reducing the height of an electronically steered circular array of monopole antennas composed of a central active element surrounded by passive elements being either short- or open-circuited. It is shown that a considerable height reduction can be achieved using top hats attached to monopoles ends and by applying dielectric coating underneath the top hats. The trade-off in achieving height reduction is narrower impedance bandwidth.
Resumo:
Eye injuries in squash have the potential to be severe. Although these injuries can be prevented through the use of protective eyewear, few players wear such eyewear. The aim of this paper is, to outline the behavioural principles guiding the design of a squash eyewear promotion initiative, the Protective Eyewear Promotion (PEP). Ecological principles of behaviour change were used to provide a comprehensive perspective on intrapersonal factors, policies and physical environmental influences of protective eyewear use. Results of baseline player surveys and venue manager inter-views were used to provide relevant and specific intervention content. At baseline, protective eyewear was not found to be readily available, and players' behaviours, knowledge and attitudes did not favour its use. The main components of PEP involved informing and educating both players and squash venue operators of the risk of eye injury and of appropriate protective eyewear, as well as assisting with the availability of the eyewear and offering incentives for players to use it. A structural strength of PEP was the strong collaborative links with the researchers of different disciplines, the squash governing body, eyewear manufacturers, squash venue personnel, as well as players. Attempts were made within the project structure to make provision for the future dissemination and sustainability of more widespread eye injury prevention measures in the sport of squash.
Resumo:
Sports venues are in a position to potentially influence the safety practices of their patrons. This study examined the knowledge, beliefs and attitudes of venue operators that could influence the use of protective eyewear by squash players. A 50% random sample of all private and public squash venues affiliated with the Victorian Squash Federation in metropolitan Melbourne was selected. Face-to-face interviews were conducted with 15 squash venue operators during August 2001. Interviews were transcribed and content and thematic analyses were performed. The content of the interviews covered five topics: (1) overall injury risk perception, (2) eye injury occurrence, (3) knowledge, behaviors, attitudes and beliefs associated with protective eyewear, (4) compulsory protective eyewear and (5) availability of protective eyewear at venues. Venue operators were mainly concerned with the severe nature of eye injuries, rather than the relatively low incidence of these injuries. Some venue operators believed that players should wear any eyewear, rather than none at all, and believed that more players should use protective eyewear. Generally, they did not believe that players with higher levels of experience and expertise needed to wear protective eyewear when playing. Only six venues had at least one type of eyewear available for players to hire or borrow or to purchase. Operators expressed a desire to be informed about correct protective eyewear. Appropriate protective eyewear is not readily available at squash venues. Better-informed venue operators may be more likely to provide suitable protective eyewear.
Distribution of melamine in polyester-melamine surface coatings cured under nonisothermal conditions
Resumo:
The influence of experimental cure parameters on the diffusion of reactive species in polyester-melamine thermoset coatings during curing has been investigated with X-ray photoelectron spectroscopy and attenuated total reflectance Fourier transform infrared. The diffusion of melamine plays a vital role in the curing process and, therefore, in the ultimate properties of coatings. At a low (
Resumo:
This paper presents results on the preparation of microcapsules containing liquid organosilica, and their co-deposition with copper in an acidic copper electrolyte onto a carbon steel cathode to form a copper/microcapsule composite coating. Microscopic analyses of the surface and the cross-section of the coating confirm the incorporation of the liquid-containing microcapsules in the coating layer. The influence of microcapsules in the electrolyte on the cathode polarization, as well as that of process conditions on the microcapsule inclusion, is also discussed. (C) 2004 Kluwer Academic Publishers.
Resumo:
The protective antigen (PA) of anthrax toxin binds to a cell surface receptor, undergoes heptamerization, and binds the enzymatic subunits, the lethal factor (LF) and the edema factor (EF). The resulting complex is then endocytosed. Via mechanisms that depend on the vacuolar ATPase and require membrane insertion of PA, LF and EF are ultimately delivered to the cytoplasm where their targets reside. Here, we show that membrane insertion of PA already occurs in early endosomes, possibly only in the multivesicular regions, but that subsequent delivery of LF to the cytoplasm occurs preferentially later in the endocytic pathway and relies on the dynamics of internal vesicles of multivesicular late endosomes.
Resumo:
Using native chemical ligation, we synthesized a group A streptococcal. (GAS) vaccine that contained three different GAS M protein peptide epitopes in a chemically well-characterized construct in high purity. Two of the peptide epitopes represented variable amino terminal serotype determinants, and the third represented a carboxyl terminal conserved region determinant of the GAS M protein. We also synthesized a lipid core peptide (LCP) construct containing the same three peptides. Upon immunization of mice, the non-LCP construct only elicited antibody responses to all three epitopes with the use of adjuvant. The LCP construct, however, elicited excellent antibody responses to all three epitopes without the need for any additional adjuvant or carrier. We have synthesized the LCP synthetic vaccine system with good reproducibility.
Resumo:
Self-report surveys are a common method of collecting data on protective equipment use in sport. The aim of this study was to assess the validity of self-reported use of appropriate protective eyewear by squash players. Surveys of squash players' appropriate protective eyewear behaviours were conducted over two consecutive years (2002 and 2003) at randomly-selected squash venues in Melbourne, Australia. Over the two years, 1219 adult players were surveyed (response rate of 92%). Trained observers also recorded the actual on-court appropriate protective eyewear behaviours of all players during the survey sessions. Eyewear use rates calculated from both data sources were compared. The self-reported appropriate protective eyewear use rate (9.4%; 95% CI 7.8, 11.0) was significantly higher (1.6 times more) than the observed rate (5.9%; 95%CI 4.6, 7.2). This suggests that players may over-report their use of appropriate protective equipment, though some may have incorrectly classified their eyewear as being appropriate or suitably protective. Studies that rely only on self-report data on protective equipment use need to take into account that this could lead to biased estimates.
Resumo:
The effect of the beta phase in Mg-Al alloys on the corrosion performance of an anodised coating was studied. It was found that the corrosion resistance of the anodised coating was closely associated with the corrosion performance of the substrate alloy. In particular, Mg alloys with a dual phase microstructure of alpha + beta with intermediate aluminium contents (namely 5%, 10% and 22% Al) after anodisation had the highest corrosion rate and the worst corrosion resistance provide by the anodised coating. The poor performance of an anodised coating was attributed partly to lower corrosion resistance of the substrate alloy and partly to the higher porosity of the anodised coating. (c) 2004 Elsevier Ltd. All rights reserved.