44 resultados para permanent magnet motor

em University of Queensland eSpace - Australia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Almost all clinical magnetic resonance imaging systems are based on circular cross-section magnets. Recent advances in elliptical cross-section RF probe and gradient coil hardware raise the question of the possibility of using elliptical cross-section magnet systems, This paper presents a methodology for calculating rapidly the magnetic fields generated by a multi-turn coil of elliptical cross-section and incorporates this in a stochastic optimization method for magnet design, An open magnet system of elliptical cross-section is designed that both reduces the claustrophobia for the patients and allows ready access by attending physicians, The magnet system is optimized for paediatric use, The coil geometry produced by the optimization method has several novel features.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Magnetic resonance microscopy (MRM) depends on the use of high field, superconducting magnet systems for its operation. The magnets that are conventionally used are those that were initially designed for chemical structural analysis work. A novel, compact magnet designed specifically for MRM is presented here, and while preserving high field, high homogeneity conditions, has a length less than one-third that of conventional systems. This enables much better access to samples, an important consideration in many MRM experiments. As the homogeneity of a magnet is strongly dependent on its length, novel geometries and optimization techniques are required to meet the requirements of MRM in a compact system. An important outcome of the stochastic optimization performed in this work, is that the use used of a thin superconducting solenoid surrounded by counterwound disk windings provides a mechanism for drastic length reductions over conventional magnet designs. (C) 1998 American Institute of Physics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Imaging of the head and neck is the most commonly performed clinical magnetic resonance imaging (MRI) examination [R. G. Evans and J. R. G. Evans, AJR 157, 603 (1991)]. This is usually undertaken in a generalist MRI instrument containing superconducting magnet system capable of imaging all organs. These generalist instruments are large, typically having a bore of 0.9-1.0 m and a length of 1.7-2.5 m and therefore are expensive to site, somewhat claustrophobic to the patient, and offer little access by attending physicians. In this article, we present the design of a compact, superconducting MRI magnet for head and neck imaging that is less than 0.8 m in length and discuss in detail the design of an asymmetric gradient coil set, tailored to the magnet profile. In particular, the introduction of a radio-frequency FM modulation scheme in concert with a gradient sequence allows the epoch of the linear region of the gradient set to be much closer to the end of the gradient structure than was previously possible. Images from a prototype gradient set demonstrate the effectiveness of the designs. (C) 1999 American Institute of Physics. [S0034-6748(99)04910-2].

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes a hybrid numerical method for the design of asymmetric magnetic resonance imaging magnet systems. The problem is formulated as a field synthesis and the desired current density on the surface of a cylinder is first calculated by solving a Fredholm equation of the first kind. Nonlinear optimization methods are then invoked to fit practical magnet coils to the desired current density. The field calculations are performed using a semi-analytical method. A new type of asymmetric magnet is proposed in this work. The asymmetric MRI magnet allows the diameter spherical imaging volume to be positioned close to one end of the magnet. The main advantages of making the magnet asymmetric include the potential to reduce the perception of claustrophobia for the patient, better access to the patient by attending physicians, and the potential for reduced peripheral nerve stimulation due to the gradient coil configuration. The results highlight that the method can be used to obtain an asymmetric MRI magnet structure and a very homogeneous magnetic field over the central imaging volume in clinical systems of approximately 1.2 m in length. Unshielded designs are the focus of this work. This method is flexible and may be applied to magnets of other geometries. (C) 1999 Academic Press.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent research (Kuhl, 1991) has suggested that the internal structure of vowel categories is graded in terms of stimulus goodness. It has been proposed that a best instance stimulus reflects a central point or prototype, which effectively renders within-category members perceptually more similar. Discrimination experiments suggest a nonlinear relationship between acoustic and perceptual space near category centers (Iverson & Kuhl, 1995b). This phenomenon has been described as the perceptual magnet effect. The present study investigated the presence of the perceptual magnet effect in five Australian vowel categories. Australian English speakers identified, rated, and discriminated between a pool of 32 vowel stimuli that varied in F1 and F2 values. The results from Experiments 1 and 2 showed that subjects were able to judge the quality and identity of each stimulus and that a general grading of stimulus quality was reported. This was not symmetrical, and the subjects' responses varied considerably. In Experiment 3, closer control of the methodology in the discrimination task and of contextual factors influencing the test materials was exercised. Despite this, evidence of the warping of perceptual space in discrimination data was not found. In general, these results do not provide support for the existence of the perceptual magnet effect, and explanations for this finding are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The 75 kD low-affinity neurotrophin receptor (p75(NTR)) is expressed in developing and axotomised spinal motor neurons. There is now convincing evidence that p75NTR can, under some circumstances, become cytotoxic and promote neuronal cell death. We report here that a single application of antisense p75(NTR) oligodeoxynucleotides to the proximal nerve stumps of neonatal rats significantly reduces the loss of axotomised motor neurons compared to controls treated with nonsense oligodeoxynucleotides or phosphate-buffered saline. Our investigations also show that daily systemic intraperitoneal injections of antisense p75(NTR) oligodeoxynucleotides for 14 days significantly reduce the loss of axotomised motor neurons compared to controls. Furthermore, we found that systemic delivery over a similar period continues to be effective following axotomy when intraperitoneal injections were 1) administered after a delay of 24 hr, 2) limited to the first 7 days, or 3) administered every third day. In addition, p75(NTR) protein levels were reduced in spinal motor neurons following treatment with antisense p75(NTR) oligodeoxynucleotides. There were also no obvious side effects associated with antisense p75(NTR) oligodeoxynucleotide treatments as determined by behavioural observations and postnatal weight gain. Our findings indicate that antisense-based strategies could be a novel approach for the prevention of motor neuron degeneration associated with injuries or disease. (C) 2001 Wiley-Liss, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The current study was designed to confirm that female drivers sit closer to the steering wheel than do male drivers and to investigate whether this expected difference in sitting position is attributable to differences in the physical dimensions of men and women. Driver body dimensions and multiple measures of sitting distance from the steering wheel were collected from a sample of 150 men and 150 women. The results confirmed that on average, women sit closer to the steering wheel than men do and that this difference is accounted for by variations in body dimensions, especially height. This result suggests that driver height may provide a good surrogate for sitting distance from the steering wheel when investigating the role of driver position in real-world crash outcomes. The potential applications of this research include change to vehicle design that allows independent adjustment of the relative distance among the driver's seat, the steering wheel, and the floor pedals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We used positron emission tomography (PET) with O-15-labelled water to record patterns of cerebral activation in six patients with Parkinson's disease (PD), studied when clinically off and after turning on as a result of dopaminergic stimulation. They were asked to imagine a Finger opposition movement performed with their right hand. externally paced at a rate of 1 Hz. Trials alternating between motor imagery and rest were measured. A pilot study of three age-matched controls was also performed. We chose the task as a robust method of activating the supplementary motor area (SMA), defects of which have been reported in PD. The PD patients showed normal de-rees of activation of the SMA (proper) when both off and on. Significant activation with imagining movement also occurred in the ipsilateral inferior parietal cortex (both off and when on) and ipsilateral premotor cortex (when off only). The patients showed significantly greater activation of the rostral anterior cingulate and significantly less activation of the left lingual gyrus and precuneus when performing the task on compared with their performance when off. PD patients when imagining movement and off showed less activation of several sites including the right dorsolateral prefrontal cortex (DLPFC) when compared to the controls performing the same task. No significant differences from controls were present when the patients imagined when on. Our results are consistent with other studies showing deficits of pre-SMA function in PD with preserved function of the SMA proper. In addition to the areas of reduced activation (anterior cingulate, DLPFC), there were also sites of activation (ipsilateral premotor and inferior parietal cortex) previously reported as locations of compensatory overactivity for PD patients performing similar tasks. Both failure of activation and compensatory changes a-re likely to contribute to the motor deficit in PD. (C) 2001 Movement Disorder Society.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigated the recruitment behaviour of low threshold motor units in flexor digitorum superficialis by altering two biomechanical constraints: the load against which the muscle worked and the initial muscle length. The load was increased using isotonic (low load), loaded dynamic (intermediate load) and isometric (high load) contractions in two studies. The initial muscle position reflected resting muscle length in series A, and a longer length with digit III fully extended in series B. Intramuscular EMG was recorded from 48 single motor units in 10 experiments on five healthy subjects, 21 units in series A and,27 in series B, while subjects performed ramp up, hold and ramp down contractions. Increasing the load on the muscle decreased the force, displacement and firing rate of single motor units at recruitment at shorter muscle lengths (P < 0.001, dependent t-test). At longer muscle lengths this recruitment pattern was observed between loaded dynamic and isotonic contractions, but not between isometric and loaded dynamic contractions. Thus, the recruitment properties of single motor units in human flexor digitorum superficialis are sensitive to changes in both imposed external loads and the initial length of the muscle. (C) 2003 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present study, we analyzed how high-frequency repetitive transcranial magnetic stimulation (rTMS) of the primary motor hand area (M1-Hand) shapes anticipatory motor activity in frontal areas as indexed by the contingent negative variation (CNV). Eight right-handed volunteers received real or sham 5 Hz rTMS at an intensity of 90% resting motorthreshold (1500 stimuli per session). Real but not sham rTMS to left M1-Hand induced a site-specific increase in amplitude of the late component of the CNV at the electrode C3 overlaying the site of stimulation. The increase in pre-movement activity in the stimulated cortex may reflect an increase in facilitatory drive from connected motor areas, enhanced responsiveness of the stimulated cortex to these inputs or both. (c) 2005 Elsevier Ireland Ltd. All rights reserved.