3 resultados para parallel algorithm
em University of Queensland eSpace - Australia
Resumo:
Bragg diffraction peak profiles and intensities in asymmetric (Omega-2theta) diffraction using a mirror-based parallel-beam geometry were compared with symmetric parallel-beam (theta-2theta) and conventional Bragg - Brentano (theta-2theta) diffraction for a powdered quartz sample and the NIST standard reference material (SRM) 660a (LaB6, lanthanum hexaboride). A comparison of the intensities and line widths (full width at half-maximum, FWHM) of these techniques demonstrated that low incident angles (Omega < 5&DEG;) are preferable for the parallel-beam setup. For higher &UOmega; values, if 2θ < 2Omega, mass absorption reduces the intensities significantly compared with the Bragg - Brentano setup. The diffraction peak shapes for the mirror geometry are more asymmetric and have larger FWHM values than corresponding peaks recorded with a Bragg - Brentano geometry. An asymmetric mirror-based parallel-beam geometry offers some advantages in respect of intensity when compared with symmetric geometries, and hence may be well suited to quantitative studies, such as those involving Rietveld analysis. A trial Rietveld refinement of a 50% quartz - 50% corundum mixture was performed and produced adequate results.
Resumo:
Objective: The description and evaluation of the performance of a new real-time seizure detection algorithm in the newborn infant. Methods: The algorithm includes parallel fragmentation of EEG signal into waves; wave-feature extraction and averaging; elementary, preliminary and final detection. The algorithm detects EEG waves with heightened regularity, using wave intervals, amplitudes and shapes. The performance of the algorithm was assessed with the use of event-based and liberal and conservative time-based approaches and compared with the performance of Gotman's and Liu's algorithms. Results: The algorithm was assessed on multi-channel EEG records of 55 neonates including 17 with seizures. The algorithm showed sensitivities ranging 83-95% with positive predictive values (PPV) 48-77%. There were 2.0 false positive detections per hour. In comparison, Gotman's algorithm (with 30 s gap-closing procedure) displayed sensitivities of 45-88% and PPV 29-56%; with 7.4 false positives per hour and Liu's algorithm displayed sensitivities of 96-99%, and PPV 10-25%; with 15.7 false positives per hour. Conclusions: The wave-sequence analysis based algorithm displayed higher sensitivity, higher PPV and a substantially lower level of false positives than two previously published algorithms. Significance: The proposed algorithm provides a basis for major improvements in neonatal seizure detection and monitoring. Published by Elsevier Ireland Ltd. on behalf of International Federation of Clinical Neurophysiology.
Resumo:
A new control algorithm using parallel braking resistor (BR) and serial fault current limiter (FCL) for power system transient stability enhancement is presented in this paper. The proposed control algorithm can prevent transient instability during first swing by immediately taking away the transient energy gained in faulted period. It can also reduce generator oscillation time and efficiently make system back to the post-fault equilibrium. The algorithm is based on a new system energy function based method to choose optimal switching point. The parallel BR and serial FCL resistor can be switched at the calculated optimal point to get the best control result. This method allows optimum dissipation of the transient energy caused by disturbance so to make system back to equilibrium in minimum time. Case studies are given to verify the efficiency and effectiveness of this new control algorithm.