10 resultados para SRM module
em University of Queensland eSpace - Australia
Resumo:
A specialised reconfigurable architecture is targeted at wireless base-band processing. It is built to cater for multiple wireless standards. It has lower power consumption than the processor-based solution. It can be scaled to run in parallel for processing multiple channels. Test resources are embedded on the architecture and testing strategies are included. This architecture is functionally partitioned according to the common operations found in wireless standards, such as CRC error correction, convolution and interleaving. These modules are linked via Virtual Wire Hardware modules and route-through switch matrices. Data can be processed in any order through this interconnect structure. Virtual Wire ensures the same flexibility as normal interconnects, but the area occupied and the number of switches needed is reduced. The testing algorithm scans all possible paths within the interconnection network exhaustively and searches for faults in the processing modules. The testing algorithm starts by scanning the externally addressable memory space and testing the master controller. The controller then tests every switch in the route-through switch matrix by making loops from the shared memory to each of the switches. The local switch matrix is also tested in the same way. Next the local memory is scanned. Finally, pre-defined test vectors are loaded into local memory to check the processing modules. This paper compares various base-band processing solutions. It describes the proposed platform and its implementation. It outlines the test resources and algorithm. It concludes with the mapping of Bluetooth and GSM base-band onto the platform.
Resumo:
Purpose: Although manufacturers of bicycle power monitoring devices SRM and Power Tap (PT) claim accuracy to within 2.5%, there are limited scientific data available in support. The purpose of this investigation was to assess the accuracy of SRM and PT under different conditions. Methods: First, 19 SRM were calibrated, raced for 11 months, and retested using a dynamic CALRIG (50-1000 W at 100 rpm). Second, using the same procedure, five PT were repeat tested on alternate days. Third, the most accurate SRM and PT were tested for the influence of cadence (60, 80, 100, 120 rpm), temperature (8 and 21degreesC) and time (1 h at similar to300 W) on accuracy. Finally, the same SRM and PT were downloaded and compared after random cadence and gear surges using the CALRIG and on a training ride. Results: The mean error scores for SRM and PT factory calibration over a range of 50-1000 W were 2.3 +/- 4.9% and -2.5 +/- 0.5%, respectively. A second set of trials provided stable results for 15 calibrated SRM after 11 months (-0.8 +/- 1.7%), and follow-up testing of all PT units confirmed these findings (-2.7 +/- 0.1%). Accuracy for SRM and PT was not largely influenced by time and cadence; however. power output readings were noticeably influenced by temperature (5.2% for SRM and 8.4% for PT). During field trials, SRM average and max power were 4.8% and 7.3% lower, respectively, compared with PT. Conclusions: When operated according to manufacturers instructions, both SRM and PT offer the coach, athlete, and sport scientist the ability to accurately monitor power output in the lab and the field. Calibration procedures matching performance tests (duration, power, cadence, and temperature) are, however, advised as the error associated with each unit may vary.
Resumo:
Grid connected PhotoVoltaic (PV) inverters fall into three broad categories — Central, String and Module Integrated Converers (MICs). MICs offer any avantaes in performance and flexibility, but are at a cost disadvantage. Two alternative novel approaches proposed by the author — cascaded dc-dc MICs and bypass dc-dc MICs — integrate a simple non-isolated intelligent dc-dc converter with each PV module to provide the advantages of dc-ac MICs at a lower cost. A suitable universal 150W 5A dc-dc converter design is presented based on two interleaved MOSFET half bridges. Testing shows Zero Voltage Switching (ZVS) keeps losses under 1W for bi-directional power flows up to 15W between two adjacent 12V PV modules for the bypass application, and efficiencies over 94% for most of the operational power range for the cascaded converter application. Based on the experimental results, potential optimizations to further reduce losses are discussed.
Resumo:
A specialised reconfigurable architecture for telecommunication base-band processing is augmented with testing resources. The routing network is linked via virtual wire hardware modules to reduce the area occupied by connecting buses. The number of switches within the routing matrices is also minimised, which increases throughput without sacrificing flexibility. The testing algorithm was developed to systematically search for faults in the processing modules and the flexible high-speed routing network within the architecture. The testing algorithm starts by scanning the externally addressable memory space and testing the master controller. The controller then tests every switch in the route-through switch matrix by making loops from the shared memory to each of the switches. The local switch matrix is also tested in the same way. Next the local memory is scanned. Finally, pre-defined test vectors are loaded into local memory to check the processing modules. This algorithm scans all possible paths within the interconnection network exhaustively and reports all faults. Strategies can be inserted to bypass minor faults