10 resultados para SCM

em University of Queensland eSpace - Australia


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to examine the spatio-temporal activation of the sternocleidomastoid (SCM) and cervical extensor (CE) muscles with respect to the deltoid muscle onset during rapid voluntary upper limb movement in healthy volunteers. The repeatability and reliability of the spatio-temporal aspects of the myoelectric signals were also examined. Ten subjects performed bilateral and unilateral rapid upper limb flexion, abduction and extension in response to a visual stimulus. EMG onsets and normalised root mean square (nRMS) values were calculated for the SCM and CE muscles. Subjects attended three testing sessions over non-consecutive days allowing the repeatability and reliability of these measures to be assessed. The SCM and CE muscles demonstrated feed-forward activation (activation within 50 ms of deltoid onset) during rapid arm movements in all directions. The sequence and magnitude of neck muscle activation displayed directional specificity, however, the neck flexor and extensor muscles displayed co-activation during all perturbations. EMG onsets demonstrated high repeatability in terms of repeated measure precision (nSEM in the range 1.9-5.7%). This was less evident for the repeatability of nRMS values. The results of this study provide a greater understanding of cervical neuromotor control strategies. During bilateral and unilateral upper limb perturbations, the SCM and CE muscles demonstrate feed-forward co-activation. It seems apparent that feed-forward activation of neck muscles is a mechanism necessary to achieve stability for the visual and vestibular systems, whilst ensuring stabilisation and protection of the cervical spine. (C) 2004 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: This study compared the neuromuscular efficiency (NME) of the sternocleidomastoid (SCM) and anterior scalene (AS) muscles between 20 chronic neck pain patients and 20 asymptomatic controls. Method: Myoelectric signals were recorded from the sternal head of SCM and the AS muscles as subjects performed sub-maximal isometric cervical flexion contractions at 25 and 50% of the maximum voluntary contraction (MVC). The NME was calculated as the ratio between MVC and the corresponding average rectified value of the EMG signal. Ultrasonography was used to measure subcutaneous tissue thickness over the SCM and AS to ensure that differences did not exist between groups. Results: For both the SCM and AS muscles, NME was shown to be significantly reduced in patients with neck pain at 25% MVC (p < 0.05). Subcutaneous tissue thickness over the SCM and AS muscles was not different between groups. Conclusions: Reduced NME in the superficial cervical flexor muscles in patients with neck pain may be a measurable altered muscle strategy for dysfunction in other muscles. This aberrant pattern of muscle activation appears to be most evident under conditions of low load. NME, when measured at 25% MVC, may be a useful objective measure for future investigation of muscle dysfunction in patients with neck pain.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this study was to compare onset of deep and superficial cervical flexor muscle activity during rapid, unilateral arm movements between ten patients with chronic neck pain and 12 control subjects. Deep cervical flexor (DCF) electromyographic activity (EMG) was recorded with custom electrodes inserted via the nose and fixed by suction to the posterior mucosa of the oropharynx. Surface electrodes were placed over the sternocleidomastoid (SCM) and anterior scalene (AS) muscles. While standing, subjects flexed and extended the right arm in response to a visual stimulus. For the control group, activation of DCF, SCM and AS muscles occurred less than 50 ms after the onset of deltoid activity, which is consistent with feedforward control of the neck during arm flexion and extension. When subjects with a history of neck pain flexed the arm, the onsets of DCF and contralateral SCM and AS muscles were significantly delayed (p<0.05). It is concluded that the delay in neck muscle activity associated with movement of the arm in patients with neck pain indicates a significant deficit in the automatic feedforward control of the cervical spine. As the deep cervical muscles are fundamentally important for support of the cervical lordosis and the cervical joints, change in the feedforward response may leave the cervical spine vulnerable to reactive forces from arm movement.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Despite the evidence of greater fatigability of the cervical flexor muscles in neck pain patients, the effect of unilaterality of neck pain on muscle fatigue has not been investigated. This study compared myoelectric manifestations of sternocleidomastoid (SCM) and anterior scalene (AS) muscle fatigue between the painful and non-painful sides in patients with chronic unilateral neck pain. Myoelectric signals were recorded from the sternal head of SCM and the AS muscles bilaterally during sub-maximal isometric cervical flexion contractions at 25% and 50% of the maximum voluntary contraction (MVC). The time course of the mean power frequency, average rectified value and conduction velocity of the electromyographic signals were calculated to quantify myoelectric manifestations of muscle fatigue. Results revealed greater estimates of the initial value and slope of the mean frequency for both the SCM and AS muscles on the side of the patient's neck pain at 25% and 50% of MVC. These results indicate greater myoelectric manifestations of muscle fatigue of the superficial cervical flexor muscles ipsilateral to the side of pain. This suggests a specificity of the effect of pain on muscle function and hence the need for specificity of therapeutic exercise in the management of neck pain patients. (C) 2003 European Federation of Chapters of the International Association for the Study of Pain. Published by Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Control of the neck muscles is coordinated with the sensory organs of vision, hearing and balance. For instance, activity of splenius capitis (SC) is modified with gaze shift. This interaction between eye movement and neck muscle activity is likely to influence the control of neck movement. The aim of this study was to investigate the effect of eye position on neck muscle activity during cervical rotation. In eleven subjects we recorded electromyographic activity (EMG) of muscles that rotate the neck to the right [right obliquus capitis inferior (OI), multifides (MF), and SC, and left sternocleidomastoid (SCM)] with intramuscular or surface electrodes. In sitting, subjects rotated the neck in each direction to specific points in range that were held statically with gaze either fixed to a guide (at three different positions) that moved with the head to maintain a constant intra-orbit eye position or to a panel in front of the subject. Although right SC and left SCM EMG increased with rotation to the right, contrary to anatomical texts, OI EMG increased with both directions and MF EMG did not change from the activity recorded at rest. During neck rotation SCM and MF EMG was less when the eyes were maintained with a constant intra-orbit position that was opposite to the direction of rotation compared to trials in which the eyes were maintained in the same direction as the head movement. The inter-relationship between eye position and neck muscle activity may affect the control of neck posture and movement.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Controlled polishing procedures were used to produce both uniformly doped and p-n junction silicon samples with different interface state densities but identical oxide thicknesses. Using these samples, the effects of interface states on scanning capacitance microscopy (SCM) measurements could be singled out. SCM measurements on the junction samples were performed with and without illumination from the atomic force microscopy laser. Both the interface charges and the illumination were seen to affect the SCM signal near p-n junctions significantly. SCM p-n junction dopant profiling can be achieved by avoiding or correctly modeling these two factors in the experiment and in the simulation. (c) 2005 American Institute of Physics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: The purpose of this study was to investigate whether an endurance-strength training program is effective in reducing myoelectric manifestations of sternocleidomastoid (SCM) and anterior scalene (AS) muscle fatigue which have been found to be greater in people with chronic neck pain. Methods: Fifty-eight female patients with chronic non-severe neck pain were randomized into one of two 6-week exercise intervention groups: an endurance-strength training regime for the cervical flexor muscles or a referent exercise intervention involving low load retraining of the cranio-cervical flexor muscles. The primary outcomes were a change in maximum voluntary contraction (MVC) force and change of the initial value and rate of change of the mean frequency, average rectified value and conduction velocity detected from the SCM and AS muscles during sub-maximal isometric cervical flexion contractions at 50, 25 and 10% MVC. Results: At the 7th week follow-up assessment, the endurance-strength training group revealed a significant increase in MVC force and a reduction in the estimates of the initial value and rate of change of the mean frequency for both the SCM and AS muscles (P < 0.05). Both exercise groups reported a reduced average intensity of neck pain and reduced neck disability index score (P < 0.05). Conclusions: An endurance-strength exercise regime for the cervical flexor muscles is effective in reducing myoelectric manifestations of superficial cervical flexor muscle fatigue as well as increasing cervical flexion strength in a group of patients with chronic non-severe neck pain. Significance: Provision of load to challenge the neck flexor muscles is required to reduce the fatigability of the SCM and AS muscles in people with neck pain. Improvements in cervical muscle strength and reduced fatigability may be responsible for the reported efficacy with this type of exercise program. (c) 2006 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All fights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Perceptions of America as a powerful but malevolent nation decrease its security. On the basis of measures derived from the stereotype content model (SCM) and image theory (IT), 5,000 college students in I I nations indicated their perceptions of the personality traits of, intentions of, and emotional reactions to the United States as well as their reactions to relevant world events (e.g., 9/11). The United States was generally perceived as competent but cold and arrogant. Although participants distinguished between the United States' government and its citizens, differences were small. Consistent with the SCM and IT, viewing the United States as intent on domination predicted perceptions of lack of warmth and of arrogance but not of competence and status. The discussion addresses implications for terrorist recruitment and ally support.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Acuity for elbow joint position sense (JPS) is reduced when head position is modified. Movement of the head is associated with biomechanical changes in the neck and shoulder musculoskeletal system, which may explain changes in elbow JPS. The present study aimed to determine whether elbow JPS is also influenced by illusory changes in head position. Simultaneous vibration of sternocleidomastoid (SCM) and the contralateral splenius was applied to 14 healthy adult human subjects. Muscle vibration or passive head rotation was introduced between presentation and reproduction of a target elbow position. Ten out of 14 subjects reported illusions consistent with lengthening of the vibrated muscles. In these 10 subjects, absolute error for elbow JPS increased with left SCM/right splenius vibration but not with right SCM/left splenius vibration. Absolute error also increased with right rotation, with a trend for increased error with left rotation. These results demonstrated that both actual and illusory changes in head position are associated with diminished acuity for elbow JPS, suggesting that the influence of head position on upper limb JPS depends, at least partially, on perceived head position.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Scanning capacitance microscopy (SCM) measurement is a proposed tool for dopant profile extraction for semiconductor material. The influence of interface traps on SCM dC/dV data is still unclear. In this paper we report on the simulation work used to study the nature of SCM dC/dV data in the presence of interface traps. A technique to correctly simulate dC/dV of SCM measurement is then presented based on our justification. We also analyze how charge of interface traps surrounding SCM probe would affect SCM dC/dV due the small SCM probe dimension.