58 resultados para Optimal placement of sensors
em University of Queensland eSpace - Australia
Resumo:
We explore the task of optimal quantum channel identification and in particular, the estimation of a general one-parameter quantum process. We derive new characterizations of optimality and apply the results to several examples including the qubit depolarizing channel and the harmonic oscillator damping channel. We also discuss the geometry of the problem and illustrate the usefulness of using entanglement in process estimation.
Resumo:
The design of randomized controlled trials entails decisions that have economic as well as statistical implications. In particular, the choice of an individual or cluster randomization design may affect the cost of achieving the desired level of power, other things being equal. Furthermore, if cluster randomization is chosen, the researcher must decide how to balance the number of clusters, or sites, and the size of each site. This article investigates these interrelated statistical and economic issues. Its principal purpose is to elucidate the statistical and economic trade-offs to assist researchers to employ randomized controlled trials that have desired economic, as well as statistical, properties. (C) 2003 Elsevier Inc. All rights reserved.
Resumo:
Monitoring of marine reserves has traditionally focused on the task of rejecting the null hypothesis that marine reserves have no impact on the population and community structure of harvested populations. We consider the role of monitoring of marine reserves to gain information needed for management decisions. In particular we use a decision theoretic framework to answer the question: how long should we monitor the recovery of an over-fished stock to determine the fraction of that stock to reserve? This exposes a natural tension between the cost (in terms of time and money) of additional monitoring, and the benefit of more accurately parameterizing a population model for the stock, that in turn leads to a better decision about the optimal size for the reserve with respect to harvesting. We found that the optimal monitoring time frame is rarely more than 5 years. A higher economic discount rate decreased the optimal monitoring time frame, making the expected benefit of more certainty about parameters in the system negligible compared with the expected gain from earlier exploitation.
Resumo:
This study investigates the effects of morningness-eveningness orientation and time-of-day on persuasion. In an attitude change paradigm, 120 female participants read a persuasive message that consisted of six counter-attitudinal arguments (anti-voluntary euthanasia) either in the morning (8:30 a.m.) or in the evening (7:00 p.m.). Attitude change was assessed by measuring attitudes towards the target issue before and after exposure to the message. Message processing was assessed by thought-listing and message recall tasks. Self-reported mood and arousal were monitored throughout. Participants were classified into M- and E-types according to their scores on the Horne and Ostberg (1976) MEQ questionnaire. When tested at their respective optimal time-of-day (i.e., morning for M-types/evening for E-types), M- and E-types reported higher energetic arousal, greater agreement with the message, greater message-congruent thinking, and a propensity for superior message recall compared to M- and E-types tested at their nonoptimal time-of-day (i.e., evening for M-types/morning for E-types). The attitude change in those tested at their optimal time-of-day was mediated by the level of message-congruent thinking. Results are interpreted in terms of the Elaboration Likelihood Model of persuasion. (c) 2005 Elsevier Ltd. All rights reserved.
Resumo:
Monoclonal antibodies (Mab) are heterotetramers consisting of an equimolar ratio of heavy chain (HC) and light chain (LC) polypeptides. Accordingly, most recombinant Mab expression systems utilize an equimolar ratio of heavy chain (he) to light chain (lc) genes encoded on either one or two plasmids. However, there is no evidence to suggest that this gene ratio is optimal for stable or transient production of recombinant Mab. In this study we have determined the optimal ratio of hc:lc genes for production of a recombinant IgG(4) Mab, cB72.3, by Chinese hamster ovary (CHO) cells using both empirical and mathematical modeling approaches. Polyethyleneimine-mediated transient expression of cB72.3 at varying ratios of hc:lc genes encoded on separate plasmids yielded an optimal Mab titer at a hc:lc gene ratio of 3:2; a conclusion confirmed by separate mathematical modeling of the Mab folding and assembly process using transient expression data. On the basis of this information, we hypothesized that utilization of he genes at low hc:lc gene ratios is more efficient. To confirm this, cB72.3 Mab was transiently produced by CHO cells at constant he and varying lc gene dose. Under these conditions, Mab yield was increased with a concomitant increase in lc gene dose. To determine if the above findings also apply to stably transfected CHO cells producing recombinant Mab, we compared the intra- and extracellular ratios of HC and LC polypeptides for three GS-CHO cells lines transfected with a 1:1 ratio of hc:lc genes and selected for stable expression of the same recombinant Mab, cB72.3. Intra- and extracellular HC:LC polypeptide ratios ranged from 1:2 to 1:5, less than that observed on transient expression of the same Mab in parental CHO cells using the same vector. In conclusion, our data suggest that the optimal ratio of hc:lc genes used for transient and stable expression of Mab differ. In the case of the latter, we infer that optimal Mab production by stably transfected cells represents a compromise between HC abundance limiting productivity and the requirement for excess LC to render Mab folding and assembly more efficient.
Resumo:
The schema of an information system can significantly impact the ability of end users to efficiently and effectively retrieve the information they need. Obtaining quickly the appropriate data increases the likelihood that an organization will make good decisions and respond adeptly to challenges. This research presents and validates a methodology for evaluating, ex ante, the relative desirability of alternative instantiations of a model of data. In contrast to prior research, each instantiation is based on a different formal theory. This research theorizes that the instantiation that yields the lowest weighted average query complexity for a representative sample of information requests is the most desirable instantiation for end-user queries. The theory was validated by an experiment that compared end-user performance using an instantiation of a data structure based on the relational model of data with performance using the corresponding instantiation of the data structure based on the object-relational model of data. Complexity was measured using three different Halstead metrics: program length, difficulty, and effort. For a representative sample of queries, the average complexity using each instantiation was calculated. As theorized, end users querying the instantiation with the lower average complexity made fewer semantic errors, i.e., were more effective at composing queries. (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
Ancillary service plays a key role in maintaining operation security of the power system in a competitive electricity market. The spinning reserve is one of the most important ancillary services that should be provided effectively. This paper presents the design of an integrated market for energy and spinning reserve service with particular emphasis on coordinated dispatch of bulk power and spinning reserve services. A new market dispatching mechanism has been developed to minimize the cost of service while maintaining system security. Genetic algorithms (GA) are used for finding the global optimal solutions for this dispatch problem. Case studies and corresponding analyses have been carried out to demonstrate and discuss the efficiency and usefulness of the proposed method.
Resumo:
This paper presents an approach for optimal design of a fully regenerative dynamic dynamometer using genetic algorithms. The proposed dynamometer system includes an energy storage mechanism to adaptively absorb the energy variations following the dynamometer transients. This allows the minimum power electronics requirement at the mains power supply grid to compensate for the losses. The overall dynamometer system is a dynamic complex system and design of the system is a multi-objective problem, which requires advanced optimisation techniques such as genetic algorithms. The case study of designing and simulation of the dynamometer system indicates that the genetic algorithm based approach is able to locate a best available solution in view of system performance and computational costs.
Resumo:
Background: Fetal pulse oximetry (FPO) may improve the assessment of the fetal well-being in labour. Reports of health-care provider's evaluations of new technology are important in the overall evaluation of that technology. Aims: To determine doctors' and midwives' perceptions of their experience placing FPO sensors. Methods: We surveyed clinicians (midwives and doctors) following placement of a FPO sensor during the FOREMOST trial (multicentre randomised trial of fetal pulse oximetry). Clinicians rated ease of sensor placement (poor, fair, good and excellent). Potential influences on ease of sensor placement (staff category, prior experience in Birth Suite, prior experience in placing sensors, epidural analgesia, cervical dilatation and fetal station) were examined by ordinal regression. Results: There were 281 surveys returned for the 294 sensor placement attempts (response rate 96%). Sensors were placed by midwives (29%), research midwives (48%), registrars (22%) and obstetricians (1%). The majority of clinicians had 1 or more years' Birth Suite experience, had placed six or more sensors previously, and rated ease of sensor placement as good. Advancing fetal station (P < 0.001) and the presence of epidural analgesia prior to sensor placement (P = 0.029) predicted improved ease of sensor placement. Having a clinician placing a sensor for the first time predicted a lower rating for ease of sensor placement (P = 0.001), compared to having placed one or more sensors previously. Conclusions: Clinicians with varying levels of Birth Suite experience successfully placed fetal oxygen saturation sensors, with the majority rating ease of sensor placement as good.