34 resultados para Microscopy of materials

em University of Queensland eSpace - Australia


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Transmission electron microscopy has been used to study the microstructure of an experimental white cast iran, in which a combination of modified alloy composition and unconventional heat treatment has resulted in a fracture toughness of 40 MPa m(-1/2). Microstructural features of the alloy that contribute to the toughness improvement and hence distinguish it from conventional white irons have been investigated. In the as-cast condition the dendrites are fully austenitic and the eutectic consists of M7C3 carbides and martensite. During heat treatment at 1130 degrees C the austenite is partially destabilized by precipitation of chromium-rich M7C3 carbides. This results in a dendritic microconstituent consisting of bulk retained austenite and secondary carbides which are sheathed with martensite. The martensite sheaths, which contain interlath films of retained austenite, are irregular in shape with some laths extending into the bulk retained austenite. Emphasis has been placed on the morphology, distribution, and stability of the retained austenite and its transformation products in the dendrites. The implications of these findings on the transformation toughening mechanism in this alloy are discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a critical analysis of the Bachelor of Materials Engineering programme compared with the expectations of the Institution of Engineers Australia (IEAust) and of UQ. To set the scene, the graduate attributes are listed, the programme framework is presented and the educational culture and available facilities are described Then, the programme delivery is described; this includes an analysis of the learning opportunities that allow students to develop the graduate attributes. Finally, an assessment is made of programme outcomes relating to graduate attributes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Reasons for performing study: Obtaining magnetic resonance images of the inner hoof wall tissue at the microscopic level would enable early accurate diagnosis of laminitis and therefore more effective therapy. Objectives: To optimise magnetic resonance imaging (MRI) parameters in order to obtain the highest possible resolution of the structures beneath the equine hoof wall. Methods: Magnetic resonance microscopy (MRM) was performed in front feet from 6 cadaver horses using T-2-weighted fast spin echo (FSE-T-2), and T-1-weighted gradient echo (GRE-T-1) sequences. Results: In T-2 weighted FSE images most of the stratum medium showed no signal, however the coronary, terminal and sole papillae were visible. The stratum lamellatum was clearly visible and primary epidermal lamellae could be differentiated from dermal lamellae. Conclusion: Most structures beneath the hoof wall were differentiated. Conventional scanners for diagnostic MRI in horses are low or high field. However this study used ultra-high field scanners currently not available for clinical use. Signal-to-noise ratio (SIN) increases as a function of field strength. An increase of spatial resolution of the image results in a decreased SIN. SIN can also be improved with better coils and the resolution of high field MRI scanners will increase as technology develops and surface array coils become more readily available. Potential relevance: Although MR images with microscopic resolution were obtained ex vivo, this study demonstrates the potential for detection of lamellar pathology as it occurs. Early recognition of the development of laminitis to instigate effective therapy at an earlier stage and may improve the outcome for laminitic horses. Clinical MR is now readily available at 3 T, while 4 T, 7 T and 9 T systems are being used for human whole body applications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Microtome sections of proton exchange membrane cells produce a wide range of information ranging from macroscopic distribution of components through specimens in which the detailed distribution of catalyst particles can be observed. Using modern data management practices it is possible to combine information at different scales and correlate processing and performance data. Analytical electron microscopy reveals the compositional variations across used cells at the electrolyte/electrode interface. In particular analytical techniques indicate that sulphur concentrations are likely to diminish at the interface Nafion/anode interface. © 2006 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE. The purpose of this study was to examine occupational therapists' use and perceptions of written education materials for clients and the factors that therapists consider before distributing written materials to clients This study also aimed to determine whether use and perceptions of these materials differed for older clients METHOD. A random sample of 50 occupational therapists from Queensland, Australia, working in adult physical disabilities settings was surveyed with a structured questionnaire Data were analyzed descriptively and with nonparametric statistics RESULTS. Of 49 participants who used written materials, 54% had given them to more than halt of their last 10 clients, regardless of the clients' age Written materials, most often information sheets developed by the participants themselves; handwritten notes; and pamphlets were principally used to reinforce verbal information. Clients' cognitive abilities, primary language, communication skills, vision, and level of education most often were considered before distributing written materials Although participants generally were positive about the content and effectiveness of materials, ratings were significantly less positive related to older clients CONCLUSION. Client education was a core treatment modality for participants in this study, with written media most commonly being used to supplement verbal education Because participants were least positive about the effectiveness of written materials for older clients, further development of materials for this audience may be indicated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study evaluated the suitability of written materials for stroke survivors and their carers. Twenty stroke survivors and 14 carers were interviewed about the stroke information they had received and their perceptions of the content and presentation of materials of increasing reading difficulty. The mean readability level of materials (grade 9) was higher than participants’ mean reading ability (grade 7–8). Satisfaction with materials decreased as the content became more difficult to read. Seventy-five percent reported that their information needs were not met in hospital. More stroke survivors with aphasia wanted support from health professionals to read and understand written information, and identified simple language, large font size, color, and diagrams to complement the text as being important features of written materials. Simple materials that meet clients’ information needs and design preferences may optimally inform them about stroke.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Powder metallurgy alloys are typically inhomogeneous with a significant amount of porosity. This complicates conventional transmission electron microscopy sample preparation. However, the use of focused ion beam milling allows site specific transmission electron microscopy samples to be prepared in a short amount of time. This paper presents a method that can be used to produce transmission electron microscopy samples from an Al-Cu-Mg PM alloy. (C) 2003 IoM Communications Ltd. Published by Maney for the Institute of Materials, Minerals and Mining.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents results on the preparation of microcapsules containing liquid organosilica, and their co-deposition with copper in an acidic copper electrolyte onto a carbon steel cathode to form a copper/microcapsule composite coating. Microscopic analyses of the surface and the cross-section of the coating confirm the incorporation of the liquid-containing microcapsules in the coating layer. The influence of microcapsules in the electrolyte on the cathode polarization, as well as that of process conditions on the microcapsule inclusion, is also discussed. (C) 2004 Kluwer Academic Publishers.