72 resultados para MRI quantitative
em University of Queensland eSpace - Australia
Resumo:
In this study we present a novel automated strategy for predicting infarct evolution, based on MR diffusion and perfusion images acquired in the acute stage of stroke. The validity of this methodology was tested on novel patient data including data acquired from an independent stroke clinic. Regions-of-interest (ROIs) defining the initial diffusion lesion and tissue with abnormal hemodynamic function as defined by the mean transit time (MTT) abnormality were automatically extracted from DWI/PI maps. Quantitative measures of cerebral blood flow (CBF) and volume (CBV) along with ratio measures defined relative to the contralateral hemisphere (r(a)CBF and r(a)CBV) were calculated for the MTT ROIs. A parametric normal classifier algorithm incorporating these measures was used to predict infarct growth. The mean r(a)CBF and r(a)CBV values for eventually infarcted MTT tissue were 0.70 +/-0.19 and 1.20 +/-0.36. For recovered tissue the mean values were 0.99 +/-0.25 and 1.87 +/-0.71, respectively. There was a significant difference between these two regions for both measures (P
Resumo:
Background: The aim of this study was to examine minor physical anomalies and quantitative measures of the head and face in patients with psychosis vs healthy controls. Methods: Based on a comprehensive prevalence study of psychosis, we recruited 310 individuals with psychosis and 303 controls. From this sample, we matched 180 case-control pairs for age and sex. Individual minor physical anomalies and quantitative measures related to head size and facial height and depth were compared within the matched pairs. Based on all subjects, we examined the specificity of the findings by comparing craniofacial summary scores in patients with nonaffective or affective psychosis and controls. Results: The odds of having a psychotic disorder were increased in those with wider skull bases (odds ratio [OR], 1.40; 95% confidence interval [CI], 1.02-1.17), smaller lower-facial heights (glabella to subnasal) (OR, 0.57; 95% CI, 0.44-0.75), protruding ears (OR, 1.72; 95% CI, 1.05-2.82), and shorter (OR, 2.29; 95% CI, 1.37-3.82) and wider (OR, 2.28; 95% CI, 1.43-3.65) palates. Compared with controls, those with psychotic disorder had skulls that were more brachycephalic. These differences were found to distinguish patients with nonaffective and affective psychoses from controls. Conclusions: Several of the features that differentiate patients from controls relate to the development of the neuro-basicranial complex and the adjacent temporal and frontal lobes. Future research should examine both the temporal lobe and the middle cranial fossa to reconcile our anthropomorphic findings and the literature showing smaller temporal lobes in patients with schizophrenia. Closer attention to the skull base may provide clues to the nature and timing of altered brain development in patients with psychosis.
Resumo:
Left ventricular (LV) volumes have important prognostic implications in patients with chronic ischemic heart disease. We sought to examine the accuracy and reproducibility of real-time 3D echo (RT-3DE) compared to TI-201 single photon emission computed tomography (SPECT) and cardiac magnetic resonance imaging (MRI). Thirty (n = 30) patients (age 62±9 years, 23 men) with chronic ischemic heart disease underwent LV volume assessment with RT-3DE, SPECT, and MRI. Ano vel semi-automated border detection algorithmwas used by RT-3DE. End diastolic volumes (EDV) and end systolic volumes (ESV) measured by RT3DE and SPECT were compared to MRI as the standard of reference. RT-3DE and SPECT volumes showed excellent correlation with MRI (Table). Both RT- 3DE and SPECT underestimated LV volumes compared to MRI (ESV, SPECT 74±58 ml versus RT-3DE 95±48 ml versus MRI 96±54 ml); (EDV, SPECT 121±61 ml versus RT-3DE 169±61 ml versus MRI 179±56 ml). The degree of ESV underestimation with RT-3DE was not significant.
Resumo:
Almost all clinical magnetic resonance imaging systems are based on circular cross-section magnets. Recent advances in elliptical cross-section RF probe and gradient coil hardware raise the question of the possibility of using elliptical cross-section magnet systems, This paper presents a methodology for calculating rapidly the magnetic fields generated by a multi-turn coil of elliptical cross-section and incorporates this in a stochastic optimization method for magnet design, An open magnet system of elliptical cross-section is designed that both reduces the claustrophobia for the patients and allows ready access by attending physicians, The magnet system is optimized for paediatric use, The coil geometry produced by the optimization method has several novel features.
Resumo:
A simple design process for the design of elliptical cross-section, transverse gradient coils for use in magnetic resonance imaging (MRI) is presented. This process is based on a flexible stochastic optimization method and results in designs of high linearity and efficiency with low switching times. A design study of a shielded, transverse asymmetric elliptical coil set for use in neural imaging is presented and includes the minimization of the torques experienced by the gradient set.
Resumo:
A sensitive and reproducible solid-phase extraction (SPE) method for the quantification of oxycodone in human plasma was developed. Varian Certify SPE cartridges containing both C-8 and benzoic acid functional groups were the most suitable for the extraction of oxycodone and codeine (internal standard), with consistently high (greater than or equal to 80%) and reproducible recoveries. The elution mobile phase consisted of 1.2 ml of butyl chloride-isopropanol (80:20, v/v) containing 2% ammonia. The quantification limit for oxycodone was 5.3 pmol on-column. Within-day and inter-day coefficients of variation were 1.2% and 6.8% respectively for 284 nM oxycodone and 9.5% and 6.2% respectively for 28.4 nM oxycodone using 0.5-ml plasma aliquots. (C) 1998 Elsevier Science BN. All rights reserved.
Resumo:
A novel three-axis gradient set and RF resonator for orthopedic MRT has been designed and constructed. The set is openable and may be wrapped around injured joints. The design methodology used was the minimization of magnetic field spherical harmonics by simulated annealing. Splitting of the longitudinal coil presents the major design challenge to a fully openable gradient set and in order to efficiently design such coils, we have developed a new fast algorithm for determining the magnetic field spherical harmonics generated by an are of multiturn wire. The algorithm allows a realistic impression of the effect of split longitudinal designs. A prototype set was constructed based on the new designs and tested in a 2-T clinical research system. The set generated 12 mT/m/A with a linear region of 12 cm and a switching time of 100 mu s, conforming closely with theoretical predictions. Preliminary images from the set are presented. (C) 1999 Academic Press.
Resumo:
This paper describes a hybrid numerical method for the design of asymmetric magnetic resonance imaging magnet systems. The problem is formulated as a field synthesis and the desired current density on the surface of a cylinder is first calculated by solving a Fredholm equation of the first kind. Nonlinear optimization methods are then invoked to fit practical magnet coils to the desired current density. The field calculations are performed using a semi-analytical method. A new type of asymmetric magnet is proposed in this work. The asymmetric MRI magnet allows the diameter spherical imaging volume to be positioned close to one end of the magnet. The main advantages of making the magnet asymmetric include the potential to reduce the perception of claustrophobia for the patient, better access to the patient by attending physicians, and the potential for reduced peripheral nerve stimulation due to the gradient coil configuration. The results highlight that the method can be used to obtain an asymmetric MRI magnet structure and a very homogeneous magnetic field over the central imaging volume in clinical systems of approximately 1.2 m in length. Unshielded designs are the focus of this work. This method is flexible and may be applied to magnets of other geometries. (C) 1999 Academic Press.
Resumo:
In this study, we examined qualitative and quantitative measures involving the head and face in a sample of patients and well controls drawn from the Brisbane Psychosis Study. Patients with psychosis (n=310) and age and sex-matched controls (n=303) were drawn from a defined catchment area. Features assessed involved hair whorls (position, number, and direction), eyes (epicanthus), supraorbital ridge, ears (low set, protrusion, hypoplasia, ear lobe attachment, asymmetry, helix width), and mouth (palate height and shape, palate ridges, furrowed and bifid tongue). Quantitative measures related to skull size (circumference, width and length) selected facial heights and depths. The impact of selected risk factors (place and season of birth, fathers' occupation at time of birth, selfreported pregnancy and birth complications, family history) were examined in the entire group, while the association between age of onset and dysmorphology was assessed within the patient group. Significant group (cases versus controls) differences included: patients had smaller skull bases, smaller facial heights, larger facial depths, lower set and protruding ears, different palate shape and fewer palate ridges. In the entire sample significant associations included: (a) those with positive family history of mental illness bad smaller head circumference, cranial length and facial heights; (b) pregnancy and birth complications was associated with smaller facial beights: (c) larger head circumference was associated with higher ranked fathers' occupations at birth. Within the patient group, age of onset was significantly lower in those with more qualitative anomalies or with larger facial heights. The group differences were not due to outliers or distinct subgroups, suggesting that the factors responsible for the differences may be subtle and widely dispersed in the patient group. The Stanley Foundation supported this project.
Resumo:
Magnetic resonance imaging (MRI) relies on the physical properties of unpaired protons in tissues to generate images. Unpaired protons behave like tiny bar magnets and will align themselves in a magnetic field. Radiofrequency pulses will excite these aligned protons to higher energy states. As they return to their original state, they will release this energy as radio waves. The frequency of the radio waves depends on the local magnetic field and by varying this over a subject, it is possible to build the images we are familiar with. In general, MRI has not been sufficiently sensitive or specific in the assessment of diffuse liver disease for clinical use. However, because of the specific characteristics of fat and iron, it may be useful in the assessment of hepatic steatosis and iron overload. Magnetic resonance imaging is useful in the assessment of focal liver disease, particularly in conjunction with contrast agents. Haemangiomas have a characteristic bright appearance on T-2 weighted images because of the slow flowing blood in dilated sinusoids. Focal nodular hyperplasia (FNH) has a homogenous appearance, and enhances early in the arterial phase after gadolinium injection, while the central scar typically enhances late. Hepatic adenomas have a more heterogenous appearance and also enhance in the arterial phase, but less briskly than FNH. Hepatocellular carcinoma is similar to an adenoma, but typically occurs in a cirrhotic liver and has earlier washout of contrast. The appearance of metastases depends on the underlying primary malignancy. Overall, MRI appears more sensitive and specific than computed tomography with contrast for the detection and evaluation of malignant lesions. (C) 2000 Blackwell Science Asia Pty Ltd.