19 resultados para Intraclass Correlation Coefficient
em University of Queensland eSpace - Australia
Resumo:
Documentation of burn sequelae can be a difficult and time-consuming task. To date a reliable and systematic format for recording postburn trauma is lacking. The purpose of this research was two-fold: first, to develop a Modified Inventory of Potential Reconstructive Needs from the original Inventory of Potential Reconstructive Needs to allow methodical documentation of functional and cosmetic burn sequelae in all body surface areas of children with burns and, second, to establish interrater reliability and concurrent validity of the instrument, thus allowing its clinical application. Two raters scored the Modified Inventory of Potential Reconstructive Needs on 41 children with a range of burns types and severity. Excellent interrater reliability was demonstrated for both total (intraclass correlation coefficient = 0.996) and subsection inventory scores. Concurrent validity was also established with total scores showing strong positive correlations (0.73-0.76) with three indicators of burn severity. These findings provide initial support for the tool's clinical applicability, particularly in relation to rehabilitative planning and documentation.
Resumo:
Objective. Eliminating health disparities, including those that are a result of socioeconomic status (SES), is one of the overarching goals of Healthy People 2010. This article reports on the development of a new, adolescent-specific measure of subjective social status (SSS) and on initial exploratory analyses of the relationship of SSS to adolescents' physical and psychological health. Methods. A cross-sectional study of 10 843 adolescents and a subsample of 166 paired adolescent/mother dyads who participated in the Growing Up Today Study was conducted. The newly developed MacArthur Scale of Subjective Social Status (10-point scale) was used to measure SSS. Paternal education was the measure of SES. Indicators of psychological and physical health included depressive symptoms and obesity, respectively. Linear regression analyses determined the association of SSS to depressive symptoms, and logistic regression determined the association of SSS to overweight and obesity, controlling for sociodemographic factors and SES. Results. Mean society ladder ranking, a subjective measure of SES, was 7.2 ± 1.3. Mean community ladder ranking, a measure of perceived placement in the school community, was 7.6 ± 1.7. Reliability of the instrument was excellent: the intraclass correlation coefficient was 0.73 for the society ladder and 0.79 for the community ladder. Adolescents had higher society ladder rankings than their mothers (µteen = 7.2 ± 1.3 vs µmom = 6.8 ± 1.2; P = .002). Older adolescents' perceptions of familial placement in society were more closely correlated with maternal subjective perceptions of placement than those of younger adolescents (Spearman's rhoteens
Resumo:
The repeatability of initial values and rate of change of EMG signal mean spectral frequency (MNF), average rectified values (ARV), muscle fiber conduction velocity (CV) and maximal voluntary contraction (MVC) was investigated in the vastus medialis obliquus (VMO) and vastus lateralis (VL) muscles of both legs of nine healthy male subjects during voluntary, isometric contractions sustained for 50 s at 50% MVC. The values of MVC were recorded for both legs three times on each day and for three subsequent days, while the EMG signals have been recorded twice a day for three subsequent days. The degree of repeatability was investigated using the Fisher test based upon the ANalysis Of VAriance (ANOVA), the Standard Error of the Mean (SEM) and the Intraclass Correlation Coefficient (ICC). Data collected showed a high level of repeatability of MVC measurement (normalized SEM from 1.1% to 6.4% of the mean). MNF and ARV initial values also showed a high level of repeatability (ICC > 70% for all muscles and legs except right VMO). At 50% MVC level no relevant pattern of fatigue was observed for the VMO and VL muscles, suggesting that other portions of the quadriceps might have contributed to the generated effort. These observations seem to suggest that in the investigation of muscles belonging to a multi-muscular group at submaximal level, the more selective electrically elicited contractions should be preferred to voluntary contractions. (C) 2001 Elsevier Science Ltd. All rights reserved.
Resumo:
In this study we examined the repeatability and reliability of the surface electromyographic (sEMG) signal mean frequency (MNF), average rectified value (ARV) and conduction velocity (CV) measured for the sternocleidomastoid (SCM) and the anterior scalene (AS) muscles in nine healthy volunteers during 15-s isometric cervical flexion contractions at 50% of the maximal voluntary contraction level over 3 non-consecutive days. Repeatability and reliability estimates were obtained for the initial values and rates of change of each sEMG variable by using both the Intraclass Correlation Coefficient (ICC) and the normalised standard error of the mean (nSEM). Results from SCM indicated good levels of repeatability for the initial value and slope of ARV (ICC > 65%). For the AS, high levels of repeatability were identified for the initial value of MNF (ICC > 70%) and the slope of ARV (ICC > 75%). Values of nSEM in the range 2.8-7.2% were obtained for the initial values of MNF and CV for both SCM and AS, indicating clinically acceptable measurement precision. The low value obtained for the nSEM of the initial value of MNF for the AS, in combination with the high ICC, indicates that of all of the variables examined, this variable could offer the best normative index to distinguish between subjects with and without neck pain, and represents the sEMG variable of choice for future evaluation purposes.
Resumo:
Objective: The aim of the present study was to investigate the between-days reliability of electromyographic (EMG) measurement of 6 bilateral trunk muscles and also the torque output in 3 planes during isometric right and left axial rotation at different exertion levels. Methods: Ten healthy subjects performed isometric right and left axial rotation at 100, 70, 50 and 30% maximum voluntary contractions in two testing sessions at least 7 days apart. EMG amplitude and frequency analyses of the recorded surface EMG signals were performed for rectus abdominis, external oblique, internal oblique, latissimus dorsi, iliocostalis lumborum and multifidus bilaterally. The primary torque in the transverse plane and the coupling torques in sagittal and coronal planes were measured. Results: For both EMG amplitude and frequency values, good (intraclass correlation coefficient, ICC = 0.75-0.89) to excellent (ICC greater than or equal to 0.90) reliability was found in the 6 trunk muscles at different exertion levels during axial rotation. The reliability of both maximal isometric axial rotation torque and coupling torques in sagittal and coronal planes were found to be excellent (ICC greater than or equal to 0.93). Conclusions: Good to excellent reliability of EMG measures of trunk muscles and torque measurements during isometric axial rotation was demonstrated. This provides further confidence of using EMG and triaxial torque assessment as outcome measures in rehabilitation and in the evaluation of the human performance in the work place. (C) 2003 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.
Resumo:
Background and Purpose. A new method of dynamometry has been developed to measure the performance of the craniocervical (CC) flexor muscles by recording the torque that these muscles exert on the cranium around the CC junction. This report describes the method, the specifications of the instrument, and the preliminary reliability data. Subjects and Methods. For the reliability study, 20 subjects (12 subjects with a history of neck pain, 8 subjects without a history of neck pain) performed, on 2 occasions, maximal voluntary isometric contraction (MVIC) tests of CC flexion in 3 positions within the range of CC flexion and submaximal sustained tests (20% and 50% of MVIC) in the middle range of CC flexion (craniocervical neutral position). Reliability coefficients were calculated to establish the test-retest reliability of the measurements. Results. The method demonstrated good reliability over 2 sessions in the measurement of MVIC (intraclass correlation coefficient [ICC] =.79-.93, SEM=0.6-1.4 N-m) and in the measurement of steadiness (standard deviation of torque amplitude) of a sustained contraction at 20% of NMC (ICC=.74-.80, SEM=0.01 N-m), but not at 50% of MVIC (ICC=.07-.76, SEM=0.04-0.13 N-m). Discussion and Conclusion. The new dynamometry method appears to have potential clinical application in the measurement of craniocervical flexor muscle performance.
Resumo:
This comment points out an inaccurate formula relating the signal correlation coefficient to the mutual impedance and corrects it. © 2005 IEEE.
Resumo:
Purpose: This study was conducted to examine the test-retest reliability of a measure of prediagnosis physical activity participation administered to colorecial cancer survivors recruited from a population-based state cancer registry. Methods: A total of 112 participants completed two telephone interviews. I month apart, reporting usual weekly physical activity in the year before their cancer diagnosis. Intraclass correlation coefficients (ICC) and standard en-or of measurement (SEM) were used to describe the test-retest reliability of the measure across the sample: the Bland-Altman approach was used to describe reliability at the individual level. The test-retest reliability for categorized total physical activity (active, insufficiently active, sedentary) was assessed using the kappa statistic. Results: When the complete sample was considered, the ICC ranged from 0.40 (95% Cl: 0.24, 0.55) for vigorous gardening to 0.77 (95% Cl: 0.68, 0.84) for moderate physical activity. The SEM, however, were large. indicating high measurement error. The Bland-Altman plots indicated that the reproducibility of data decreases as the aniount of physical activity reported each week increases The kappa coefficient for the categorized data was 0.62 (95% Cl: 0.48, 0.76). Conclusion: Overall. the results indicated low levels of repeatability for this measure of historical physical activity. Categorizing participants as active, insufficiently active, or sedentary provides a higher level of test-retest reliability.
Resumo:
The detection of seizure in the newborn is a critical aspect of neurological research. Current automatic detection techniques are difficult to assess due to the problems associated with acquiring and labelling newborn electroencephalogram (EEG) data. A realistic model for newborn EEG would allow confident development, assessment and comparison of these detection techniques. This paper presents a model for newborn EEG that accounts for its self-similar and non-stationary nature. The model consists of background and seizure sub-models. The newborn EEG background model is based on the short-time power spectrum with a time-varying power law. The relationship between the fractal dimension and the power law of a power spectrum is utilized for accurate estimation of the short-time power law exponent. The newborn EEG seizure model is based on a well-known time-frequency signal model. This model addresses all significant time-frequency characteristics of newborn EEG seizure which include; multiple components or harmonics, piecewise linear instantaneous frequency laws and harmonic amplitude modulation. Estimates of the parameters of both models are shown to be random and are modelled using the data from a total of 500 background epochs and 204 seizure epochs. The newborn EEG background and seizure models are validated against real newborn EEG data using the correlation coefficient. The results show that the output of the proposed models has a higher correlation with real newborn EEG than currently accepted models (a 10% and 38% improvement for background and seizure models, respectively).
Resumo:
The performance of three analytical methods for multiple-frequency bioelectrical impedance analysis (MFBIA) data was assessed. The methods were the established method of Cole and Cole, the newly proposed method of Siconolfi and co-workers and a modification of this procedure. Method performance was assessed from the adequacy of the curve fitting techniques, as judged by the correlation coefficient and standard error of the estimate, and the accuracy of the different methods in determining the theoretical values of impedance parameters describing a set of model electrical circuits. The experimental data were well fitted by all curve-fitting procedures (r = 0.9 with SEE 0.3 to 3.5% or better for most circuit-procedure combinations). Cole-Cole modelling provided the most accurate estimates of circuit impedance values, generally within 1-2% of the theoretical values, followed by the Siconolfi procedure using a sixth-order polynomial regression (1-6% variation). None of the methods, however, accurately estimated circuit parameters when the measured impedances were low (<20 Omega) reflecting the electronic limits of the impedance meter used. These data suggest that Cole-Cole modelling remains the preferred method for the analysis of MFBIA data.
Resumo:
A simple method for the measurement of pindolol enantiomers by HPLC is presented. Alkalinized serum or urine is extracted with ethyl acetate and the residue remaining after evaporation of the organic layer is then derivatised with (S)-(-)-alpha-methylbenzyl isocyanate. The diastereoisomers of derivatised pindolol and metoprolol (internal standard) are separated by high-performance liquid chromatography (HPLC) using a C-18 silica column and detected using fluorescence (excitation lambda: 215 nm, emission lambda: 320 nm). The assay displays reproducible linearity for pindolol enantiomers with a correlation coefficient of r(2) greater than or equal to 0.998 over the concentration range 8-100 ng ml(-1) for plasma and 0.1-2.5 mu g ml(-1) for urine. The coefficient of variation for accuracy and precision of the quality control samples for both plasma and urine are consistently
Resumo:
To predict the combustion performance in pulverized coal-fired boilers, this paper examines existing indices and develops a maceral index (MI). These indices were compared with the data of 68 coals and blends in a range of the mean vitrinite reflectance from 0.25 to 1.63. The results showed that the fuel ratio and the mean vitrinite reflectance could qualitatively indicate the burnout of the coals and blends. The new MI, MI = L + V/R-2/I-1.25(HV/30)(2.5), provides a useful correlation for the burnout of the coals and blends. The correlation coefficient (I-) is 0.982 for the EER data, and 0.808 for the ACIRL data. The MI also has potential to correlate ignition and flame stability of the coals and blends. The MI predicts the burnout better than the other indices. (C) 2001 Elsevier Science Ltd. All rights reserved.
Resumo:
Objective: To assess the intrarater and interrater reliability among rheumatologists of a standardised protocol for measurement of shoulder movements using a gravity inclinometer. Methods: After instruction, six rheurnatologists independently assessed eight movements of the shoulder, including total and glenohumeral flexion, total and glenohumeral abduction, external rotation in neutral and in abduction, internal rotation in abduction and hand behind back, in random order in six patients with shoulder pain and stiffness according to a 6x6 Latin square design using a standardised protocol. These assessments were then repeated. Analysis of variance was used to partition total variability into components of variance in order to calculate intraclass correlation coefficients (ICCs). Results: The intrarater and interrater reliability of different shoulder movements varied widely. The movement of hand behind back and total shoulder flexion yielded the highest ICC scores for both intrarater reliability (0.91 and 0.83, respectively) and interrater reliability (0.80 and 0.72, respectively). Low ICC scores were found for the movements of glenohumeral abduction, external rotation in abduction, and internal rotation in abduction (intrarater ICCs 0.35, 0.43, and 0.32, respectively), and external rotation in neutral, external rotation in abduction, and internal rotation in abduction (interrater ICCs 0.29, 0.11, and 0.06, respectively). Conclusions: The measurement of shoulder movements using a standardised protocol by rheumatologists produced variable intrarater and interrater reliability. Reasonable reliability was obtained only for the movement of hand behind back and total shoulder flexion.
Resumo:
The thin-layer drying behaviour of bananas in a beat pump dehumidifier dryer was examined. Four pre-treatments (blanching, chilling, freezing and combined blanching and freezing) were applied to the bananas, which were dried at 50 degreesC with an air velocity of 3.1 m s(-1) and with the relative humidity of the inlet air of 10-35%. Three drying models, the simple model, the two-term exponential model and the Page model were examined. All models were evaluated using three statistical measures, correlation coefficient, root means square error, and mean absolute percent error. Moisture diffusivity was calculated based on the diffusion equation for an infinite cylindrical shape using the slope method. The rate of drying was higher for the pre-treatments involving freezing. The sample which was blanched only did not show any improvement in drying rate. In fact, a longer drying time resulted due to water absorption during blanching. There was no change in the rate for the chilled sample compared with the control. While all models closely fitted the drying data, the simple model showed greatest deviation from the experimental results. The two-term exponential model was found to be the best model for describing the drying curves of bananas because its parameters represent better the physical characteristics of the drying process. Moisture diffusivities of bananas were in the range 4.3-13.2 x 10(-10) m(2)s(-1). (C) 2002 Published by Elsevier Science Ltd.
Resumo:
Purpose. Health promotion policy frameworks, recent theorizing, and research all emphasize understanding and mobilizing environmental influences to change particular health-related behaviors in specific settings. The workplace is a key environmental setting. The Checklist of Health Promotion Environments at Worksites (CHEW) was designed as a direct observation instrument to assess characteristics of worksite environments that are known to influence health-related behaviors. Methods. The CHEW is a 112-item checklist of workplace environment features hypothesized to be associated, both positively and negatively, with physical activity, healthy eating, alcohol consumption, and smoking. The three environmental domains assessed are (1) physical characteristics of the worksite, (2) features of the information environment, and (3) characteristics of the immediate neighborhood around the workplace. The conceptual rationale and development studies for the CHEW are described, and data from observational studies of 20 worksites are reported. Results. The data on CHEW-derived environmental attributes showed generally good reliability and identified meaningful sets of variables that plausibly may influence health-related behaviors. With the exception of one information environment attribute, intraclass correlation coefficients ranged from 0.80 to 1.00. Descriptive statistics on selected physical and information environment characteristics indicated that vending machines, showers, bulletin boards, and signs prohibiting smoking were common across worksites. Bicycle racks, visible stairways, and signs related to alcohol consumption, nutrition, and health. promotion were relatively uncommon. Conclusions. These findings illustrate the types of data on environmental attributes that can be derived, their relevance for program planning, and how they can characterize variability across worksites. The CHEW is a promising observational measure that has the potential to assess environmental influences on health behaviors and to evaluate workplace health promotion programs.