7 resultados para High Reliability

em University of Queensland eSpace - Australia


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Background and Purpose. Arm lymphedema following breast cancer In this study, we assessed the surgery is a continuing problem. reliability and validity of circumferential measurements and water displacement for measuring upper-limb volume. Subjects. Participants included subjects who had had breast cancer surgery, including axillary dissection-19 with and 22 without a diagnosis of arm lymphedema-and 25 control subjects. Methods. Two raters measured each subject by using circumferential tape measurements at specified distances from the fingertips and in relation to anatornic landmarks and by using water displacement. Interrater reliability was calculated by analysis of variance and multilevel modeling. Volumes from circumferential measurements were compared with those from water displacement by use of means and correlation coefficients, respectively. The standard error of measurement, minimum detectable change (MDC), and limits of agreement (LOA) for volumes also were calculated. Results. Arm volumes obtained with these methods had high reliability. Compared with volumes from water displacement, volumes from circumferential measurements had high validity, although these volumes were slightly larger. Expected differences between subjects with and without clinical lymphedema following breast cancer were found. The MDC of volumes or the error associated with a single measure for data based oil anatomic landmarks was lower than that based oil distance from fingertips. The mean LOA with water displacement were lower for data based on anatomic landmarks than for data based on distance from fingertips. Discussion and Conclusion. Volumes calculated from anatomic landmarks are reliable, valid, and more accurate than those obtained from circumferential measurements based on distance from fingertips.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to analyze the psychometric properties of the Spanish translation of the List of Social Situation Problems (LSSP; S. H. Spence, 1980). The questionnaire was administered to a sample of 388 adolescents between the ages of 12 and 18. Exploratory factor analysis identified four factors: Social Anxiety, Adult Oppositional, Assertiveness, and Making Friends, which accounted for 26.64% of the variance. Internal consistency of the total scale was high (alpha = .86). Correlations between the LSSP and two self-report measures of social anxiety, the Questionnaire about Interpersonal Difficulties for Adolescents (r = .45) and the Social Phobia and Anxiety Inventory (r = .48), were statistically significant. A significant difference was found between LSSP total scores for adolescents with and without social anxiety (d = 1.14), supporting the construct validity of the scale.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE To determine the ability of pathologists to reproducibly diagnose a newly defined lesion, i.e. the papillary urothelial neoplasm of low malignant potential (PUNLMP) using the published criteria, defined by the 1998 World Health Organisation/International Society of Urological Pathology (WHO/ISUP) classification system; in addition, debate remains about the clinical behaviour of these lesions, thus the rates of recurrence and progression of PUNLMP lesions were assessed and compared with low-grade papillary urothelial carcinomas (LG-PUC) and high-grade (HG-PUC) over a 10-year follow-up. PATIENTS AND METHODS Forty-nine cases of superficial bladder cancer (G1-3 pTa) representing an initial diagnosis of transitional cell carcinoma made in 1990 were identified and re-graded using the 1998 WHO/ISUP classification by two pathologists. Inter-observer agreement was assessed using Cohen weighted kappa statistics. After reclassification the clinical follow-up was reviewed retrospectively, and episodes of recurrence and progression recorded. RESULTS The inter-observer agreement was moderate, regardless of whether one (kappa 0.45) or two (kappa 0.60) pathologists were used to grade these lesions. Re-classification identified 12 PUNLMP, 28 LG-PUC and nine HG-PUC. PUNLMP lesions recurred in 25% (3/12) of cases; no progression was documented. Recurrence rates were 75% (21/28) and 67% (6/9) for LG- and HG-PUC, respectively, and progression rates were 4% (1/28) and 22% (2/9). CONCLUSION The 1998 WHO/ISUP classification of urothelial neoplasms can be reproducibly applied by pathologists, with a moderate level of agreement. There is evidence that PUNLMP lesions have a more indolent clinical behaviour than urothelial carcinomas. However, the risk of recurrence and progression remains, and clinical monitoring of these patients is important.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We have used an animal model to test the reliability of a new portable continuous-wave Doppler ultrasonic cardiac output monitor, the USCOM. In six anesthetized dogs, cardiac output was measured with a high-precision transit time ultrasonic flowprobe placed on the ascending aorta. The dogs' cardiac output was increased with a dopamine infusion (0-15 mug (.) kg(-1) (.) min(-1)). Simultaneous flowprobe and USCOM cardiac output measurements were made. Up to 64 pairs of readings were collected from each dog. Data were compared by using the Bland and Altman plot method and Lin's concordance correlation coefficient. A total of 319 sets of paired readings were collected. The mean (+/-SD) cardiac output was 2.62 +/- 1.04 L/min, and readings ranged from 0.79 to 5.73 L/min. The mean bias between the 2 sets of readings was -0.01 L/min, with limits of agreement (95% confidence intervals) of -0.34 to 0.31 L/min. This represents a 13% error. In five of six dogs, there was a high degree of concordance, or agreement, between the 2 methods, with coefficients >0.9. The USCOM provided reliable measurements of cardiac output over a wide range of values. Clinical trials are needed to validate the device in humans.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: This study was conducted to examine the test-retest reliability of a measure of prediagnosis physical activity participation administered to colorecial cancer survivors recruited from a population-based state cancer registry. Methods: A total of 112 participants completed two telephone interviews. I month apart, reporting usual weekly physical activity in the year before their cancer diagnosis. Intraclass correlation coefficients (ICC) and standard en-or of measurement (SEM) were used to describe the test-retest reliability of the measure across the sample: the Bland-Altman approach was used to describe reliability at the individual level. The test-retest reliability for categorized total physical activity (active, insufficiently active, sedentary) was assessed using the kappa statistic. Results: When the complete sample was considered, the ICC ranged from 0.40 (95% Cl: 0.24, 0.55) for vigorous gardening to 0.77 (95% Cl: 0.68, 0.84) for moderate physical activity. The SEM, however, were large. indicating high measurement error. The Bland-Altman plots indicated that the reproducibility of data decreases as the aniount of physical activity reported each week increases The kappa coefficient for the categorized data was 0.62 (95% Cl: 0.48, 0.76). Conclusion: Overall. the results indicated low levels of repeatability for this measure of historical physical activity. Categorizing participants as active, insufficiently active, or sedentary provides a higher level of test-retest reliability.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To establish concurrent validity, interrater and test-retest reliability of the Modified Elderly Mobility Scale (MEMS). Methods: Ninety elderly patients were scored on the MEMS. To establish concurrent validity, 75 patients MEMS scores were compared to Functional Independence Measure (FIM) scores using Spearman's correlation. Videotaped patient performances were used to establish interrater and test-retest reliability using percentage absolute agreement and intraclass correlation coefficients (ICCs). Results: The total MEMS score demonstrated a significant association with the motor (r = 0.725) and total FIM scores (r = 0.718). Absolute agreement for interrater reliability was greater than 93% for all test items, with 97 and 98% for the two new measures, respectively. Test-retest reliability demonstrated similar high levels of absolute agreement and had ICCs ranging from 0.870 to 1.0. Conclusions: The MEMS is a quick, valid and reliable test of motor function of elderly patients with a spread of functional levels.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Grid computing is an emerging technology for providing the high performance computing capability and collaboration mechanism for solving the collaborated and complex problems while using the existing resources. In this paper, a grid computing based framework is proposed for the probabilistic based power system reliability and security analysis. The suggested name of this computing grid is Reliability and Security Grid (RSA-Grid). Then the architecture of this grid is presented. A prototype system has been built for further development of grid-based services for power systems reliability and security assessment based on probabilistic techniques, which require high performance computing and large amount of memory. Preliminary results based on prototype of this grid show that RSA-Grid can provide the comprehensive assessment results for real power systems efficiently and economically.