44 resultados para Estimation errors

em University of Queensland eSpace - Australia


Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper use consider the problem of providing standard errors of the component means in normal mixture models fitted to univariate or multivariate data by maximum likelihood via the EM algorithm. Two methods of estimation of the standard errors are considered: the standard information-based method and the computationally-intensive bootstrap method. They are compared empirically by their application to three real data sets and by a small-scale Monte Carlo experiment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The choice of genotyping families vs unrelated individuals is a critical factor in any large-scale linkage disequilibrium (LD) study. The use of unrelated individuals for such studies is promising, but in contrast to family designs, unrelated samples do not facilitate detection of genotyping errors, which have been shown to be of great importance for LD and linkage studies and may be even more important in genotyping collaborations across laboratories. Here we employ some of the most commonly-used analysis methods to examine the relative accuracy of haplotype estimation using families vs unrelateds in the presence of genotyping error. The results suggest that even slight amounts of genotyping error can significantly decrease haplotype frequency and reconstruction accuracy, that the ability to detect such errors in large families is essential when the number/complexity of haplotypes is high (low LD/common alleles). In contrast, in situations of low haplotype complexity (high LD and/or many rare alleles) unrelated individuals offer such a high degree of accuracy that there is little reason for less efficient family designs. Moreover, parent-child trios, which comprise the most popular family design and the most efficient in terms of the number of founder chromosomes per genotype but which contain little information for error detection, offer little or no gain over unrelated samples in nearly all cases, and thus do not seem a useful sampling compromise between unrelated individuals and large families. The implications of these results are discussed in the context of large-scale LD mapping projects such as the proposed genome-wide haplotype map.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Despite its environmental (and financial) importance, there is no agreement in the literature as to which extractant most accurately estimates the phytoavailability of trace metals in soils. A large dataset was taken from the literature, and the effectiveness of various extractants to predict the phytoavailability of Cd, Zn, Ni, Cu, and Pb examined across a range of soil types and contamination levels. The data suggest that generally, the total soil trace metal content, and trace metal concentrations determined by complexing agents (such as the widely used DTPA and EDTA extractants) or acid extractants (such as 0.1 M HCl and the Mehlich 1 extractant) are only poorly correlated to plant phytoavailability. Whilst there is no consensus, it would appear that neutral salt extractants (such as 0.01 M CaCl2 and 0.1 M NaNO3) provide the most useful indication of metal phytoavailability across a range of metals of interest, although further research is required.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bioelectrical impedance analysis (BIA) was used to assess body composition in rats fed on either standard laboratory diet or on a high-fat diet designed to induce obesity. Bioelectrical impedance analysis predictions of total body water and thus fat-free mass (FFM) for the group mean values were generally within 5% of the measured values by tritiated water ((H2O)-H-3) dilution. The limits of agreement for the procedure were, however, large, approximately +/-25%, limiting the applicability of the technique for measurement of body composition in individual animals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Potential errors in the application of mixture theory to the analysis of multiple-frequency bioelectrical impedance data for the determination of body fluid volumes are assessed. Potential sources of error include: conductive length; tissue fluid resistivity; body density; weight and technical errors of measurement. Inclusion of inaccurate estimates of body density and weight introduce errors of typically < +/-3% but incorrect assumptions regarding conductive length or fluid resistivities may each incur errors of up to 20%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A significant problem in the collection of responses to potentially sensitive questions, such as relating to illegal, immoral or embarrassing activities, is non-sampling error due to refusal to respond or false responses. Eichhorn & Hayre (1983) suggested the use of scrambled responses to reduce this form of bias. This paper considers a linear regression model in which the dependent variable is unobserved but for which the sum or product with a scrambling random variable of known distribution, is known. The performance of two likelihood-based estimators is investigated, namely of a Bayesian estimator achieved through a Markov chain Monte Carlo (MCMC) sampling scheme, and a classical maximum-likelihood estimator. These two estimators and an estimator suggested by Singh, Joarder & King (1996) are compared. Monte Carlo results show that the Bayesian estimator outperforms the classical estimators in almost all cases, and the relative performance of the Bayesian estimator improves as the responses become more scrambled.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The truncation errors associated with finite difference solutions of the advection-dispersion equation with first-order reaction are formulated from a Taylor analysis. The error expressions are based on a general form of the corresponding difference equation and a temporally and spatially weighted parametric approach is used for differentiating among the various finite difference schemes. The numerical truncation errors are defined using Peclet and Courant numbers and a new Sink/Source dimensionless number. It is shown that all of the finite difference schemes suffer from truncation errors. Tn particular it is shown that the Crank-Nicolson approximation scheme does not have second order accuracy for this case. The effects of these truncation errors on the solution of an advection-dispersion equation with a first order reaction term are demonstrated by comparison with an analytical solution. The results show that these errors are not negligible and that correcting the finite difference scheme for them results in a more accurate solution. (C) 1999 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the adult olfactory nerve pathway of rodents, each primary olfactory axon forms a terminal arbor in a single glomerulus in the olfactory bulb. During development, axons are believed to project directly to and terminate precisely within a glomerulus without any exuberant growth or mistargeting. To gain insight into mechanisms underlying this process, the trajectories of primary olfactory axons during glomerular formation were studied in the neonatal period. Histochemical staining of mouse olfactory bulb sections with the lectin Dolichos biflorus-agglutinin revealed that many olfactory axons overshoot the glomerular layer and course into the deeper laminae of the bulb in the early postnatal period. Single primary olfactory axons were anterogradely labelled either with the lipophilic carbocyanine dye, 1,1'-dioctodecyl-3,3,3',3'-tetramethylindocarbocyanine perchlorate (DiI), or with horseradish peroxidase (HRP) by localized microinjections into the nerve fiber layer of the rat olfactory bulb. Five distinct trajectories of primary olfactory axons were observed in DLI-labelled preparations at postnatal day 1.5 (P1.5). Axons either coursed directly to and terminated specifically within a glomerulus, branched before terminating in a glomerulus, bypassed glomeruli and entered the underlying external plexiform layer, passed through the glomerular layer with side branches into glomeruli, or branched into more than one glomerulus. HRP-labelled axon arbors from eight postnatal ages were reconstructed by camera lucida and were used to determine arbor length, arbor area, and arbor branch number. Whereas primary olfactory axons display errors in laminar targeting in the mammalian olfactory bulb, axon arbors typically achieve their adult morphology without exuberant growth. Many olfactory axons appear not to recognize appropriate cues to terminate within the glomerular layer during the early postnatal period. However, primary olfactory axons exhibit precise targeting in the glomerular layer after P5.5, indicating temporal differences in either the presence of guidance cues or the ability of axons to respond to these cues. (C) 1999 Wiley-Liss, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This is the first paper in a study on the influence of the environment on the crack tip strain field for AISI 4340. A stressing stage for the environmental scanning electron microscope (ESEM) was constructed which was capable of applying loads up to 60 kN to fracture-mechanics samples. The measurement of the crack tip strain field required preparation (by electron lithography or chemical etching) of a system of reference points spaced at similar to 5 mu m intervals on the sample surface, loading the sample inside an electron microscope, image processing procedures to measure the displacement at each reference point and calculation of the strain field. Two algorithms to calculate strain were evaluated. Possible sources of errors were calculation errors due to the algorithm, errors inherent in the image processing procedure and errors due to the limited precision of the displacement measurements. Estimation of the contribution of each source of error was performed. The technique allows measurement of the crack tip strain field over an area of 50 x 40 mu m with a strain precision better than +/- 0.02 at distances larger than 5 mu m from the crack tip. (C) 1999 Kluwer Academic Publishers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background From the mid-1980s to mid-1990s, the WHO MONICA Project monitored coronary events and classic risk factors for coronary heart disease (CHD) in 38 populations from 21 countries. We assessed the extent to which changes in these risk factors explain the variation in the trends in coronary-event rates across the populations. Methods In men and women aged 35-64 years, non-fatal myocardial infarction and coronary deaths were registered continuously to assess trends in rates of coronary events. We carried out population surveys to estimate trends in risk factors. Trends in event rates were regressed on trends in risk score and in individual risk factors. Findings Smoking rates decreased in most male populations but trends were mixed in women; mean blood pressures and cholesterol concentrations decreased, body-mass index increased, and overall risk scores and coronary-event rates decreased. The model of trends in 10-year coronary-event rates against risk scores and single risk factors showed a poor fit, but this was improved with a 4-year time lag for coronary events. The explanatory power of the analyses was limited by imprecision of the estimates and homogeneity of trends in the study populations. Interpretation Changes in the classic risk factors seem to partly explain the variation in population trends in CHD. Residual variance is attributable to difficulties in measurement and analysis, including time lag, and to factors that were not included, such as medical interventions. The results support prevention policies based on the classic risk factors but suggest potential for prevention beyond these.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

.:Abstract-Objective: Bioelectrical impedance analysis (BIA) is widely used as bedside assessment of body composition. Body cell mass (BCM) and intracellular water (ICW) are clinically important body compartments. Estimates of ICW obtained from BIA by different calculation approaches were compared to a reference method in male HIV-infected patients. Patients: Representative subsample of clinically stable HIV-infected outpatients, consisting of 42 men with a body mass index of 22.4 +/- 3.8 kg/m(2) (range, 13-31 kg/m(2)). Methods: Total body potassium was assessed in a whole body counter, and compared to 50 kHz mono-frequency BIA and multifrequency bioelectrical impedance spectroscopy. Six different prediction equations for ICW from BIA data were applied. Methods were compared by the Bland-Altman method. Results: BIA-derived ICW estimates explained 58% to 73% of the observed variance in ICW (TBK), but limits of confidence were wide (-16.6 to +18.2% for the best method). BIA overestimated low ICW (TBK) and underestimated high ICW (TBK) when normalized for weight or height. Mono- and multifrequency BIA were not different in precision but population-specific equations tended to narrower confidence limits. Conclusion: BIA is an unreliable method to estimate ICW in this population, in contrast to the better established estimation of total body water and extracellular water. Potassium depletion in severe malnutrition may contribute to this finding but a major part of the residual between methods remains unexplained. (C) 2000 Harcourt Publishers Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dendritic cells (DC) are considered to be the major cell type responsible for induction of primary immune responses. While they have been shown to play a critical role in eliciting allosensitization via the direct pathway, there is evidence that maturational and/or activational heterogeneity between DC in different donor organs may be crucial to allograft outcome. Despite such an important perceived role for DC, no accurate estimates of their number in commonly transplanted organs have been reported. Therefore, leukocytes and DC were visualized and enumerated in cryostat sections of normal mouse (C57BL/10, B10.BR, C3H) liver, heart, kidney and pancreas by immunohistochemistry (CD45 and MHC class II staining, respectively). Total immunopositive cell number and MHC class II+ cell density (C57BL/10 mice only) were estimated using established morphometric techniques - the fractionator and disector principles, respectively. Liver contained considerably more leukocytes (similar to 5-20 x 10(6)) and DC (similar to 1-3 x 10(6)) than the other organs examined (pancreas: similar to 0.6 x 10(6) and similar to 0.35 x 10(6): heart: similar to 0.8 x 10(6) and similar to 0.4 x 10(6); kidney similar to 1.2 x 10(6) and 0.65 x 10(6), respectively). In liver, DC comprised a lower proportion of all leukocytes (similar to 15-25%) than in the other parenchymal organs examined (similar to 40-60%). Comparatively, DC density in C57BL/10 mice was heart > kidney > pancreas much greater than liver (similar to 6.6 x 10(6), 5 x 10(6), 4.5 x 10(6) and 1.1 x 10(6) cells/cm(3), respectively). When compared to previously published data on allograft survival, the results indicate that the absolute number of MHC class II+ DC present in a donor organ is a poor predictor of graft outcome. Survival of solid organ allografts is more closely related to the density of the donor DC network within the graft. (C) 2000 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We show that quantum feedback control can be used as a quantum-error-correction process for errors induced by a weak continuous measurement. In particular, when the error model is restricted to one, perfectly measured, error channel per physical qubit, quantum feedback can act to perfectly protect a stabilizer codespace. Using the stabilizer formalism we derive an explicit scheme, involving feedback and an additional constant Hamiltonian, to protect an (n-1)-qubit logical state encoded in n physical qubits. This works for both Poisson (jump) and white-noise (diffusion) measurement processes. Universal quantum computation is also possible in this scheme. As an example, we show that detected-spontaneous emission error correction with a driving Hamiltonian can greatly reduce the amount of redundancy required to protect a state from that which has been previously postulated [e.g., Alber , Phys. Rev. Lett. 86, 4402 (2001)].

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The amount of crystalline fraction present in monohydrate glucose crystal-solution mixture up to 110% crystal in relation to solution (crystal:solution=110:100) was determined by water activity measurement. It was found that the water activity had a strong linear correlation (R-2=0.994) with the amount of glucose present above saturation. Difference in the water activities of the crystal-solution mixture (a(w1)) and the supersaturated solution (a(w2)) by re-dissolving the crystalline fraction allowed calculation of the amount of crystalline phase present (DeltaG) in the mixture by an equation DeltaG=846.97(a(w1)-a(w2)). Other methods such as Raoult's, Norrish and Money-Born equations were also tested for the prediction of water activity of supersaturated glucose solution. (C) 2003 Swiss Society of Food Science and Technology. Published by Elsevier Science Ltd. All rights reserved.