16 resultados para CPR artifacts
em University of Queensland eSpace - Australia
Resumo:
Members of the community contribute to survival from out-of-hospital cardiac arrest by contacting emergency medical services and performing cardiopulmonary resuscitation (CPR) prior to the arrival of an ambulance. In Australia there is a paucity of information of the extent that community members know the emergency telephone number and are trained in CPR. A survey of Queensland adults (n = 4490) was conducted to ascertain current knowledge and training levels and to target CPR training. Although most respondents (88.3%) could state the Australian emergency telephone number correctly, significant age differences were apparent (P < 0.001). One in five respondents aged 60 years and older could not state the emergency number correctly. While just over half the respondents (53.9%) had completed some form of CPR training, only 12.1% had recent training. Older people were more likely to have never had CPR training than young adults. Additional demographic and socio-economic differences were found between those never trained in CPR and those who were. The results emphasise the need to increase CPR training in those aged 40 and over, particularly females, and to increase the awareness of the emergency telephone number amongst older people. (C) 2002 Elsevier Science Ireland Ltd. All rights reserved.
Resumo:
Computer Science is a subject which has difficulty in marketing itself. Further, pinning down a standard curriculum is difficult-there are many preferences which are hard to accommodate. This paper argues the case that part of the problem is the fact that, unlike more established disciplines, the subject does not clearly distinguish the study of principles from the study of artifacts. This point was raised in Curriculum 2001 discussions, and debate needs to start in good time for the next curriculum standard. This paper provides a starting point for debate, by outlining a process by which principles and artifacts may be separated, and presents a sample curriculum to illustrate the possibilities. This sample curriculum has some positive points, though these positive points are incidental to the need to start debating the issue. Other models, with a less rigorous ordering of principles before artifacts, would still gain from making it clearer whether a specific concept was fundamental, or a property of a specific technology. (C) 2003 Elsevier Ltd. All rights reserved.
Resumo:
The objectives of this study are to (1) quantify prior cardiopulmonary resuscitation (CPR) training in households of patients presenting to the Emergency Department (ED) with or without chest pain or ischaemic heart disease (IHD); (2) evaluate the willingness of household members to undertake CPR training; and (3) identify potential barriers to the learning and provision of bystander CPR. A cross-sectional study was conducted by surveying patients presenting to the ED of a metropolitan teaching hospital over a 6-month period. Two in five households of patients presenting with chest pain or IHD had prior training in CPR. This was no higher than for households of patients presenting without chest pain or IHD. Just under two in three households of patients presenting with chest pain or IHD were willing to participate in future CPR classes. Potential barriers to learning CPR included lack of information on CPR classes, perceived lack of intellectual and/or physical capability to learn CPR and concern about causing anxiety in the person at risk of cardiac arrest. Potential barriers to CPR provision included an unknown cardiac arrest victim and fear of infection. The ED provides an opportunity for increasing family and community capacity for bystander intervention through referral to appropriate training. (C) 2003 Published by Elsevier Science Ireland Ltd.
Resumo:
Opioid overdose mortality among young adults in Australia has increased consistently over the past several decades. Among Australian adults aged 15-44 years, the number of these deaths has increased from six in 1964 to 600 in 1997. The rate (per million adults in this age group) increased 55-fold, from 1.3 in 1964 to 71.5 in 1997, The proportion of all deaths in adults in this age group caused by opioid overdose increased from 0.1% in 1964 to 7.3% in 1997, The magnitude of the increase makes it unlikely to be an artefact of changes in diagnosis, especially as similar increases have also been observed in other countries. These trends are also consistent,vith historical information which indicates that illicit heroin use first came to police attention in Sydney and Melbourne in the late 1960s, There is an urgent need to implement and evaluate a variety of measures to reduce the unacceptable toll of opioid overdose deaths among young Australians. These include: peer education about the risks of polydrug use and overdose after resuming opioid use after periods of abstinence, and attracting more dependent users into opioid maintenance treatment. Measures are also needed to improve responses to overdose by encouraging witnesses to call ambulances, training drug users in CPR, and trialling distribution of the opiate antagonist naloxone to users at high risk of overdose.
Resumo:
A new method for the evaluation of radiotherapy 3D polymer gel dosimeters has been developed using ultrasound to assess the significant structural changes that occur following irradiation of the dosimeters. The ultrasonic parameters of acoustic speed of propagation, attenuation and transmitted signal intensity were measured as a function of absorbed radiation dose. The dose sensitivities for each parameter were determined as 1.8 x 10(-4) s m(-1) Gy(-1), 3.9 dB m(-1) Gy(-1) and 3.2 V-1 Gy(-1) respectively. All parameters displayed a strong variation with absorbed dose that continued beyond absorbed doses of 15 Gy. The ultrasonic measurements demonstrated a significantly larger dynamic range in dose response curves than that achieved with previously published magnetic resonance imaging (MRI) dose response data. It is concluded that ultrasound shows great potential as a technique for the evaluation of polymer gel dosimeters.
Resumo:
Off-resonance RF pre-saturation was used to obtain contrast in MRI images of polymer gel dosimeters irradiated to doses up to 50 Gy. Two different polymer gel dosimeters composed of 2-hydroxyethyl-acryl ate or methacrylic acid monomers mixed with N, N'-methylene-bisacrylamide (BIS), dispersed in an aqueous gelatin matrix were evaluated. Radiation-induced polymerization of the co-monomers generates a fast-relaxing insoluble polymer. Saturation of the polymer using off-resonance Gaussian RF pulses prior to a spin-echo read-out with a short echo time leads to contrast that is dependent on the absorbed dose. This contrast is attributed to magnetization transfer (MT) between free water and the polymer, and direct saturation of water was found to be negligible under the prevailing experimental conditions. The usefulness of MT imaging was assessed by computing the dose resolution obtained with this technique. We found a low value of dose resolution over a wide range of doses could be obtained with a single experiment. This is an advantage over multiple spin echo (MSE) experiments using a single echo spacing where an optimal dose resolution is achieved over only very limited ranges of doses. The results suggest MT imaging protocols may be developed into a useful tool for polymer gel dosimetry.
Resumo:
Inhomogeneities in the spatial distribution of the excitatory Radio Frequency (RF) field, are still a dominant source of artifacts and loss of signal to noise ratio in MR imaging experiments, A number of strategies have been proposed to quantify this distribution, However, in this technical note we present a relatively simple MR imaging procedure which can be used to visualise RF inhomogeneities directly either by means of the magnitude or the phase of an image. To visualise the RF field distribution in both the inner and outer volumes of the coil, we have performed experiments in which the entire coil is submerged in a non-conducting fluid, To the best of our knowledge this strategy has not been used previously in order to evaluate coil performance, Finally, we demonstrate that the method is sensitive enough to reveal the effects of the sample properties on the effective RF wavelength of the transmitted field. (C) 1997 Elsevier Science Inc.
Resumo:
Neurological disease or dysfunction in newborn infants is often first manifested by seizures. Prolonged seizures can result in impaired neurodevelopment or even death. In adults, the clinical signs of seizures are well defined and easily recognized. In newborns, however, the clinical signs are subtle and may be absent or easily missed without constant close observation. This article describes the use of adaptive signal processing techniques for removing artifacts from newborn electroencephalogram (EEG) signals. Three adaptive algorithms have been designed in the context of EEG signals. This preprocessing is necessary before attempting a fine time-frequency analysis of EEG rhythmical activities, such as electrical seizures, corrupted by high amplitude signals. After an overview of newborn EEG signals, the authors describe the data acquisition set-up. They then introduce the basic physiological concepts related to normal and abnormal newborn EEGs and discuss the three adaptive algorithms for artifact removal. They also present time-frequency representations (TFRs) of seizure signals and discuss the estimation and modeling of the instantaneous frequency related to the main ridge of the TFR.
Resumo:
Ultrasonic speed of propagation and attenuation were investigated as a function of absorbed radiation dose in PAG and MAGIC polymer gel dosimeters. Both PAG and MAGIC gel dosimeters displayed a dependence of ultrasonic parameters on absorbed dose with attenuation displaying significant changes in the dose range investigated. The ultrasonic attenuation dose sensitivity at 4 MHz in MAGIC gels was determined to be 4.7 +/- 0.3 dB m(-1) Gy(-1) and for PAG 3.9 +/- 0.3 dB m(-1) Gy(-1). Ultrasonic speed dose sensitivities were 0.178 +/- 0.006 m s(-1) Gy(-1) for MAGIC gel and -0.44 +/- 0.02 m s(-1) Gy(-1) for PAG. Density and compressional elastic modulus were investigated to explain the different sensitivities of ultrasonic speed to radiation for PAG and MAGIC gels. The different sensitivities were found to be due to differences in the compressional elastic modulus as a function of dose for the two formulations. To understand the physical phenomena underlying the increase in ultrasonic attenuation with dose, the viscoelastic properties of the gels were studied. Results suggest that at ultrasonic frequencies, attenuation in polymer gel dosimeters is primarily due to volume viscosity. It is concluded that ultrasonic attenuation significantly increases with absorbed dose. Also, the ultrasonic speed in polymer gel dosimeters is affected by changes in dosimeter elastic modulus that are likely to be a result of polymerization. It is suggested that ultrasound is a sufficiently sensitive technique for polymer gel dosimetry.