28 resultados para 110302 Clinical Chemistry (diagnostics)

em University of Queensland eSpace - Australia


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: A new immunoassay for free light chain measurements has been reported to be useful for the diagnosis and monitoring of monoclonal light chain diseases and nonsecretory myeloma. We describe experience with and some potential pitfalls of the assay. Methods: The assay was assessed for precision, sample type and stability, recovery, and harmonization of results between two analyzers on which the reagents are used. Free-light-chain concentrations were measured in healthy individuals (to determine biological variation), patients with monoclonal gammopathy of undetermined significance, myeloma patients after autologous stem cell transplants, and patients with renal disease. Results: Analytical imprecision (CV) was 6-11% for kappa and A free-light-chain measurement and 16% for the calculated kappa/lambda ratio. Biological variation was generally insignificant compared with analytical variation. Despite the same reagent source, values were not completely harmonized between assay systems and may produce discordant free-light-chain ratios. In some patients with clinically stable myeloma, or post transplantation, or with monoclonal gammopathy of undetermined significance, free-light-chain concentration and ratio were within the population reference interval despite the presence of monoclonal intact immunoglobulin in serum. In other patients with monoclonal gammopathy of undetermined significance, values were abnormal although there was no clinical evidence of progression to multiple myeloma. Conclusions: The use of free-light-chain measurements alone cannot differentiate some groups of patients with monoclonal gammopathy from healthy individuals. As with the introduction of any new test, it is essential that more scientific data about use of this assay in different subject groups are available so that results can be interpreted with clinical certainty. (C) 2003 American Association for Clinical Chemistry.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim: We present a descriptive analysis of the 10 case reports distributed in the Royal College of Pathologists of Australasia (RCPA) and the Australasian Association of Clinical Biochemists (AACB) Chemical Pathology Patient Report Comments Program to assess the quality of interpretative commenting in clinical biochemistry in 2001. Method: Participants were asked to comment on a given set of biochemistry results attached with brief clinical details. All responses received were translated into key phrases and graphically presented on a histogram. An expert panel was asked to evaluate the appropriateness of the key phrases and to propose a suggested composite comment. Results: While the majority of comments received were felt to be acceptable by the expert panel, some comments were felt to be inappropriate or misleading. As comments on laboratory reports may affect clinical management of patients, it is important that these comments reflect accepted practice and current guidelines. Conclusion: The Patient Report Comments Program may play an important role in continuing education and possibly in quality assurance of interpretative commenting.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The quality of reporting of studies of diagnostic accuracy is less than optimal. Complete and accurate reporting is necessary to enable readers to assess the potential for bias in the study and to evaluate the generalisability of the results. A group of scientists and editors has developed the STARD (Standards for Reporting of Diagnostic Accuracy) statement to improve the reporting the quality of reporting of studies of diagnostic accuracy. The statement consists of a checklist of 25 items and flow diagram that authors can use to ensure that all relevant information is present. This explanatory document aims to facilitate the use, understanding and dissemination of the checklist. The document contains a clarification of the meaning, rationale and optimal use of each item on the checklist, as well as a short summary of the available evidence on bias and applicability. The STARD statement, checklist, flowchart and this explanation and elaboration document should be useful resources to improve reporting of diagnostic accuracy studies. Complete and informative reporting can only lead to better decisions in healthcare.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Psychoses are relatively low prevalence disorders that have a disproportionately negative impact on individuals and society. Cannabis use is one factor that can exacerbate the negative consequences associated with psychotic disorders. Relatively few studies have examined the effects or reasons for using cannabis self-reported by individuals with psychosis. The present study is the first known to compare directly such factors in individuals with and without psychosis, within a single study. At baseline and follow-up participants with psychosis most commonly reported using cannabis for positive mood alteration (36% and 42%), coping with negative affect (27% and 29%) and for social activity reasons (38% and 29%). The control group most commonly reported using cannabis for relaxation (34% and 43%) and social activity reasons (49% and 51%). Participants with psychosis were less likely to report relaxation as the most important effect after use ( 27%) or expect it at follow-up ( 49%) compared to the control group (53% and 70%). In both groups, addiction and positive affect enhancement were the composite variable scores correlated most consistently with concurrent amount and frequency of use.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Plasma cholinesterase activity is known to be correlated with plasma triglycerides, HDL- and LDL-cholesterol, and other features of the metabolic syndrome. A role in triglyceride metabolism has been proposed. Genetic variants that decrease activity have been studied extensively, but the factors contributing to overall variation in the population are poorly understood. We studied plasma cholinesterase activity in a sample of 2200 adult twins to assess covariation with cardiovascular risk factors and components of the metabolic syndrome, to determine the degree of genetic effects on enzyme activity, and to search for quantitative trait loci affecting activity. Methods and Results: Cholinesterase activity was lower in women than in men before the age of 50, but increased to activity values similar to those in males after that age. There were highly significant correlations with variables associated with the metabolic syndrome: plasma triglyceride, HDL- and LDL-cholesterol, apolipoprotein B and E, urate, and insulin concentrations; gamma-glutamyltransferase and aspartate and alanine aminotransferase activities; body mass index; and blood pressure. The heritability of plasma cholinesterase activity was 65%. Linkage analysis with data from the dizygotic twin pairs showed suggestive linkage on chromosome 3 at the location of the cholinesterase WHO gene and also on chromosome 5. Conclusions: Our results confirm and extend the connection between cholinesterase, cardiovascular risk factors, and metabolic syndrome. They establish a substantial heritability for plasma cholinesterase activity that might be attributable to variation near the structural gene and at an independent locus. (c) 2006 American Association for Clinical Chemistry.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: The BRAF gene is frequently somatically altered in malignant melanoma. A majority of variations are at the valine 600 residue leading to a V600E substitution that constitutively activates the kinase. We screened 4000 patient and control DNAs for germ-line variations at the valine 600 residue. Methods: We developed a novel assay by adapting single-base variation assays and software for MALDI-TOF (matrix-assisted laser desorption/ionization time-of-flight) mass spectrometry to screen for all 5 reported variants at codon 600 of the BRAF gene. We screened a case-control collection comprising samples from 1082 melanoma patients and 154 of their unaffected relatives from 1278 families and from 2744 individuals from 659 unselected twin families with no history of melanoma. A panel of 66 melanoma cell lines was used for variation-positive controls. Results: All melanoma cell lines that we had found previously to carry a codon 600 variation were verified in this study. Three of the 4 possible variants (V600E n = 47, V600K n = 2, V600R n = 1) were detected, but no case of V600D was available. No germ-line variants were found in the samples from the 3980 melanoma patients or from the control individuals. Conclusions: This new assay is a high-throughput, automated alternative to standard sequencing and can be used as a rapid initial screen for somatic variants associated with melanoma. Germ-line variants at valine 600 are unlikely to exist and do not contribute to the reported role of the BRAF gene in melanoma predisposition. (c) 2006 American Association for Clinical Chemistry.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador: