129 resultados para Concrete filled double skin steel tube


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Expression of metallothionein, an antioxidant induced by a variety of stimuli including ultraviolet light, was quantitated by immunohistochemistry in the skin of males aged over 50 who had known short- and long-term exposures to sunlight. Skin punch biopsies were taken from two sites in each subject: the hand in all subjects and a range of other sites matched to patients with a previously excised primary melanoma. Metallothionein expression (strongest in the basal layers of the epidermis and primarily nuclear) was associated with both short- and long-term exposure to sunlight. A plateau of staining intensity was reached after 3 h sun exposure, within the previous 3 d before biopsy. Expression was also elevated in the nonexposed skin sites of subjects who had recent sun exposure, indicating a systemic response to exposure of remote sites. Using the skin of the hand to normalize responses to chronic exposure between individuals, the systemically modulated response to sunlight was significantly greater on the unexposed back than on other sites. The possibility of ultraviolet-induced cytokines selectively modifying the response of skin on a site-specific basis was investigated. The circulating leukocytes, but not lymphocytes, of two individuals exposed to 1 minimal erythema dose whole-body solar-simulated ultraviolet showed increased interleukin-6 mRNA 4 h after exposure. Interleukin-6 was not directly induced in these cell populations 4 h after ultraviolet A or ultraviolet B irradiation ex vivo . Leukocytes may therefore contribute to and amplify the systemic effects of ultraviolet-induced interleukin-6 and metallothionein expression.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Based on the hypothesis that limited receptor solubility of lipophilic compounds may result in lower observed permeability parameters, the aim of this study was to determine the in vitro human epidermal permeability coefficients and membrane retention of a series of aliphatic alcohols (C1-C10, log p -0.72 to 4.06) using two different receptor solutions (water and 4% bovine serum albumin in phosphate-buffered saline). Aqueous solutions of radiolabeled alcohols were dosed into the stratum corneum side of membranes mounted in side-by-side glass diffusion cells. Appearance of alcohol in the receptor compartment filled with either of the two solutions was monitored over a 7 h period when both stratum corneum (assessed by tape stripping) and the remaining epidermis levels of radioactivity were determined. In a separate study the degree of binding of alcohols to 4% bovine serum albumin was determined. The data showed increased receptor phase solubility in the bovine serum albumin solution and higher permeability coefficients for the more lipophilic alcohols in the series. No changes were seen in the partitioning of the alcohols from the vehicle into either the stratum corneum or tape-stripped epidermis with the two receptor phases; however, a decrease in the amount of the more lipophilic alcohols partitioning into the water receptor phase from the tape-stripped epidermis was observed. We conclude that bovine serum albumin receptor phase allows better estimation of real permeability parameters for lipophilic compounds due to its increased solubility capacity and we question whether permeability parameters for lipophilic solutes from older data sets based on aqueous receptor phases are completely reliable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to establish the relationship between solute lipophilicity and skin penetration (including flux and concentration behavior), we examined the in vitro penetration and membrane concentration of a series of homologous alcohols (C2-C10) applied topically in aqueous solutions to human epidermal, full-thickness, and dermal membranes. The partitioning/distribution of each alcohol between the donor solution, stratum corneum, viable epidermis, dermis, and receptor phase compartments was determined during the penetration process and separately to isolated samples of each tissue type. Maximum flux and permeability coefficients are compared for each membrane and estimates of alcohol diffusivity are made based on flux/concentration data and also the related tissue resistance (the reciprocal of permeability coefficient) for each membrane type. The permeability coefficient increased with increasing lipophilicity to alcohol C8 (octanol) with no further increase for C10 (decanol). Log vehicle:stratum corneum partition coefficients were related to logP , and the concentration of alcohols in each of the tissue layers appeared to increase with lipophilicity. No difference was measured in the diffusivity of smaller more polar alcohols in the three membranes; however, the larger more lipophilic solutes showed slower diffusivity values. The study showed that the dermis may be a much more lipophilic environment than originally believed and that distribution of smaller nonionized solutes into local tissues below a site of topical application may be estimated based on knowledge of their lipophilicity alone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To investigate the effect of lipophilicity on the percutaneous penetration of a homologous series of alcohols through canine skin Design Skin harvested from Greyhound thorax was placed in Franz-type diffusion cells and the in vitro passage of radio-labelled (C-14) alcohols (ethanol, butanol, hexanol and octanol (Log P 0.19 - 3.0)) through separate skin sections was measured in replicates of five. Permeability coefficient (k(P), cm/h), maximum flux (J(max), mol/cm(2)/h) and residue remaining within the skin were determined. Results The k(P) increased with increasing lipophilicity (6.2 x 10(-4) +/- 1.6 x 10(-4) cm/h for ethanol to 1.8 x 10(-2) 3.6 x 10(-3) cm/h for octanol). Alcohol residues remaining within each skin sample followed a similar pattern. An exponential decrease in Jmax with increasing lipophilicity was observed. Conclusion Changes in canine skin permeability occur with increasing alcohol lipophilicity. This finding has practical consequences for the design of topical formulations and optimisation of drug delivery through animal skin.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Twenty-one strains of Bacillus (10 B. stearothermophilus, 3 B. cereus, and 8 B. licheniformis strains) were assayed for spore surface hydrophobicity on the basis of three measures: contact angle measurement (CAM), microbial adhesion to hydrocarbons (MATH), and hydrophobic interaction chromatography (HIC). On the basis of the spore surface characteristics obtained from these assays, along with data on the heat resistance of these spores in water, eight strains of Bacillus (three B. stearothermophilus, three B. cereus, and two B. licheniformis strains) either suspended in water or adhering to stainless steel were exposed to sublethal heat treatments at 90 to 110degreesC to determine heat resistance (D-value). Significant increases in heat resistance (ranging from 3 to 400%) were observed for the eight strains adhering to stainless steel. No significant correlation was found between these heat resistance increases and spore surface characteristics as determined by the three hydrophobicity assays. There was a significant positive correlation between the hydrophobicity data obtained by the MATH assay and those obtained by the HIC assay, but these data did not correlate with those obtained by the CAM assay.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigate coherent electron transport through a parallel circuit of two quantum dots (QDs), each of which has a single tunable. energy level. Electrons tunnelling via each dot from the left lead interfere with each other at the right lead. It is shown that due to the quantum interference of tunnelling electrons the double QD device is magnetically polarized by coherent circulation of electrons on the closed path through the dots and the leads. By varying the energy level of each dot one can make the magnetic states of the device be up-, non- or down-polarized. It is shown that for experimentally accessible temperatures and applied biases the magnetic polarization currents Should be sufficiently large to observe with current nanotechnology.