211 resultados para TISSUE DOPPLER IMAGING


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Magnetic resonance imaging (MRI) was used to evaluate and compare with anthropometry a fundamental bioelectrical impedance analysis (BIA) method for predicting muscle and adipose tissue composition in the lower limb. Healthy volunteers (eight men and eight women), aged 41 to 62 years, with mean (S.D.) body mass indices of 28.6 (5.4) kg/m(2) and 25.1 (5.4) kg/m(2) respectively, were subjected to MRI leg scans, from which 20-cm sections of thigh and IO-cm sections of lower leg (calf) were analysed for muscle and adipose tissue content, using specifically developed software. Muscle and adipose tissue were also predicted from anthropometric measurements of circumferences and skinfold thicknesses, and by use of fundamental BIA equations involving section impedance at 50 kHz and tissue-specific resistivities. Anthropometric assessments of circumferences, cross-sectional areas and volumes for total constituent tissues matched closely MRI estimates. Muscle volume was substantially overestimated (bias: thigh, -40%; calf, -18%) and adipose tissue underestimated (bias: thigh, 43%; calf, 8%) by anthropometry, in contrast to generally better predictions by the fundamental BIA approach for muscle (bias:thigh, -12%; calf, 5%) and adipose tissue (bias:thigh, 17%; calf, -28%). However, both methods demonstrated considerable individual variability (95% limits of agreement 20-77%). In general, there was similar reproducibility for anthropometric and fundamental BIA methods in the thigh (inter-observer residual coefficient of variation for muscle 3.5% versus 3.8%), but the latter was better in the calf (inter-observer residual coefficient of variation for muscle 8.2% versus 4.5%). This study suggests that the fundamental BIA method has advantages over anthropometry for measuring lower limb tissue composition in healthy individuals.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective-To compare the accuracy and feasibility of harmonic power Doppler and digitally subtracted colour coded grey scale imaging for the assessment of perfusion defect severity by single photon emission computed tomography (SPECT) in an unselected group of patients. Design-Cohort study. Setting-Regional cardiothoracic unit. Patients-49 patients (mean (SD) age 61 (11) years; 27 women, 22 men) with known or suspected coronary artery disease were studied with simultaneous myocardial contrast echo (MCE) and SPECT after standard dipyridamole stress. Main outcome measures-Regional myocardial perfusion by SPECT, performed with Tc-99m tetrafosmin, scored qualitatively and also quantitated as per cent maximum activity. Results-Normal perfusion was identified by SPECT in 225 of 270 segments (83%). Contrast echo images were interpretable in 92% of patients. The proportion of normal MCE by grey scale, subtracted, and power Doppler techniques were respectively 76%, 74%, and 88% (p < 0.05) at > 80% of maximum counts, compared with 65%, 69%, and 61% at < 60% of maximum counts. For each technique, specificity was lowest in the lateral wail, although power Doppler was the least affected. Grey scale and subtraction techniques were least accurate in the septal wall, but power Doppler showed particular problems in the apex. On a per patient analysis, the sensitivity was 67%, 75%, and 83% for detection of coronary artery disease using grey scale, colour coded, and power Doppler, respectively, with a significant difference between power Doppler and grey scale only (p < 0.05). Specificity was also the highest for power Doppler, at 55%, but not significantly different from subtracted colour coded images. Conclusions-Myocardial contrast echo using harmonic power Doppler has greater accuracy than with grey scale imaging and digital subtraction. However, power Doppler appears to be less sensitive for mild perfusion defects.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Color Doppler ultrasound is a new method for documenting fluid leakage in the setting of video-urodynamic testing. In order to compare color Doppler ultrasound with traditional fluoroscopic imaging we performed a prospective blinded comparative clinical study. Fifty-two consecutive patients undergoing urodynamic investigations for symptoms of incontinence or prolapse were examined using fluoroscopy and translabial color Doppler ultrasound to document stress leakage. The investigators were blinded to each other's results. Both tests were performed at maximum bladder capacity and with an indwelling 5 Fr microtransducer catheter, in both the supine and the erect positions. Equivalent results for both methods were obtained in 48 out of 52 patients (Cohen's kappa = 0.82). It was therefore concluded that translabial color Doppler ultrasound imaging can reliably demonstrate leakage through the female urethra on Valsalva maneuver or coughing.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background. Regional left ventricular (LV) dysfunction may occur in patients with coronary artery disease (CAD) in the absence of infarction, but the causes of this phenomenon are unclear. We sought to identify whether changes in regional LV function were related to stenosis severity, using sensitive new ultrasound markers of function. Methods: We studied 67 individuals with no history of infarction and with normal LV systolic function: 49 patients with CAD and 18 control subjects without CAD. All patients underwent color Doppler tissue imaging, integrated backscatter (IB), anatomic M-mode echocardiography, and strain rate imaging to detect changes in structure and function. Peak early and late diastolic myocardial velocity, cyclic variation of IB, wall thickness, and percent wall thickening were measured in each basal and mid segment. Strain rate and peak systolic strain were calculated in each wall. CAD was defined as greater than or equal to 50% diameter stenosis. Normokinetic segments (n = 354) subtended by CAD were divided according to stenosis severity into 3 groups: group 1 (subtended by 50%-69% stenosis); group 2 (subtended by 70%-98% stenosis); and group 3 (subtended by greater than or equal to99% stenosis). Each parameter in each group was compared with that in 216 segments from control subjects. Results: Segments subtended by significant CAD showed lower peak early and late diastolic myocardial velocity compared with control segments. Group 3 showed significantly lower myocardial velocities than group 2 for both peak early (4.8 +/- 1.8 vs 6.0 +/- 2.0 cm/s, P

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background-Obesity is associated with heart failure, but an effect of weight, independent of comorbidities, on cardiac structure and function is not well established. We sought whether body mass index (BMI) and insulin levels were associated with subclinical myocardial disturbances. Methods and Results-Transthoracic echocardiography, myocardial Doppler-derived systolic (sm) and early diastolic velocity ( em), strain and strain rate imaging and tissue characterization with cyclic variation (CVIB), and calibrated integrated backscatter (cIB) were obtained in 109 overweight or obese subjects and 33 referents (BMI35) and the referent patients (P

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study sought the ability of strain rate imaging to detect subclinical left ventricular dysfunction, as evidenced by reduced contractile reserve (CR) in 32 asymptomatic patients with isolated severe mitral regurgitation. Compared with CR- patients (n = 10), CR+ patients (n = 22) had significantly higher end-systolic strain and peak systolic strain rate, but these parameters were not significantly different between CR+ patients and matched normal controls. (C) 2004 by Excerpta Medica, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The assessment of left ventricular (LV) dysfunction has become the most frequent indication for echocardiography, a growth that has been driven by the epidemic of heart failure. The value of echocardiography for assessing LV dysfunction is unquestionable, the quantification of both LV systolic and diastolic dysfunction being a reliable indicator of mortality. 1,2 Nonetheless, whereas the ejection fraction and diastolic assessment are important clinical parameters, they are highly dependent on loading and may produce abnormal results under unusual loading conditions. Moreover, in a number of situations where the LV is evaluated, although the overall function is an important finding, the referring clinician is really requesting an assessment of the nature of the underlying myocardial tissue (Table 1). Indeed, in some situations (eg, among family members of patients with a cardiomyopathy) questions arise about the presence of pathology despite the presence of normal ventricular function. Traditionally, it has been difficult to obtain this information because of the lack of sufficiently sensitive parameters, but a number of new developments have shown such success in this area that the clinical application of tools to assess the myocardium in routine practice appears finally to be a realistic proposition.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A finite-difference time-domain (FDTD) thermal model has been developed to compute the temperature elevation in the Sprague Dawley rat due to electromagnetic energy deposition in high-field magnetic resonance imaging (MRI). The field strengths examined ranged from 11.75-23.5 T (corresponding to H-1 resonances of 0.5-1 GHz) and an N-stub birdcage resonator was used to both transmit radio-frequency energy and receive the MRI signals. With an in-plane resolution of 1.95 mm, the inhomogeneous rat phantom forms a segmented model of 12 different tissue types, each having its electrical and thermal parameters assigned. The steady-state temperature distribution was calculated using a Pennes 'bioheat' approach. The numerical algorithm used to calculate the induced temperature distribution has been successfully validated against analytical solutions in the form of simplified spherical models with electrical and thermal properties of rat muscle. As well as assisting with the design of MRI experiments and apparatus, the numerical procedures developed in this study could help in future research and design of tumour-treating hyperthermia applicators to be used on rats in vivo.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The water characteristics in cooked pressure-heat treated (45 degreesC for 45 min prior to pressurisation at 150 MPa for 30 min) and non-pressurised, cooked (control) samples of beef Longissimus aged for 1, 3, 8 or 16 days were studied by nuclear magnetic resonance microscopy. A multi-echo sequence was used to obtain T2 images, and independent of ageing period, the T2 values were found to be lower in pressure-heat treated meat revealing alterations in water characteristics of pressure-treated, cooked meat compared with cooked meat. With increasing ageing duration, the T2 values in both pressure-treated, cooked and cooked meat decreased indicating that the water became more tightly trapped in the protein network. In addition, independent of length of ageing period the relationship between cooking loss in the cooked meat and transverse relaxation differed between non-pressurised and pressure-treated meat. which reveals that the mechanisms changing the water properties in beef during ageing are different from those occuring during pressure-heat treatment of meat. (C) 2003 Elsevier Ltd. All rights reserved.