63 resultados para Digital content
Resumo:
If the Internet could be used as a method of transmitting ultrasound images taken in the field quickly and effectively, it would bring tertiary consultation to even extremely remote centres. The aim of the study was to evaluate the maximum degree of compression of fetal ultrasound video-recordings that would not compromise signal quality. A digital fetal ultrasound videorecording of 90 s was produced, resulting in a file size of 512 MByte. The file was compressed to 2, 5 and 10 MByte. The recordings were viewed by a panel of four experienced observers who were blinded to the compression ratio used. Using a simple seven-point scoring system, the observers rated the quality of the clip on 17 items. The maximum compression ratio that was considered clinically acceptable was found to be 1:50-1:100. This produced final file sizes of 5-10 MByte, corresponding to a screen size of 320 x 240 pixels, running at 15 frames/s. This study expands the possibilities for providing tertiary perinatal services to the wider community.
Resumo:
The growth of direct marketing has been attributed to rapid advances in technology and the changing market context. The fundamental ability of direct marketers to communicate with consumers and to elicit a response, combined with the ubiquitous nature and power of mobile digital technology, provides a synergy that will increase the potential for the success of direct marketing. The aim of this paper is to provide an analytical framework identifying the developments in the digital environment from e-marketing to m-marketing, and to alert direct marketers to the enhanced capabilities available to them.
Resumo:
This paper presents the results of my action research. I was involved in establishing and running a digital library that was founded by the government of South Korea. The process involved understanding the relationship between the national IT infrastructure and the success factors of the digital library. In building, the national IT infrastructure, a digital library system was implemented; it combines all existing digitized university libraries and can provide overseas information, such as foreign journal articles, instantly and freely to every Korean researcher. An empirical survey was made as a part of the action research; the survey determined user satisfaction in the newly established national digital library. After obtaining the survey results, I suggested that the current way of running the nationwide government-owned digital library should be retained. (C) 2002 Elsevier Science B.V. All rights reserved.
Resumo:
The disposition kinetics of six cationic drugs in perfused diseased and normal rat livers were determined by multiple indicator dilution and related to the drug physicochemical properties and liver histopathology. A carbon tetrachloride (CCl4)induced acute hepatocellular injury model had a higher fibrosis index (FI), determined by computer-assisted image analysis, than did an alcohol-induced chronic hepatocellular injury model. The alcohol-treated group had the highest hepatic alpha(1)- acid glycoprotein, microsomal protein (MP), and cytochrome P450 (P450) concentrations. Various pharmacokinetic parameters could be related to the octanol-water partition coefficient (log P-app) of the drug as a surrogate for plasma membrane partition coefficient and affinity for MP or P450, the dependence being lower in the CCl4-treated group and higher in the alcohol-treated group relative to controls. Stepwise regression analysis showed that hepatic extraction ratio, permeability-surface area product, tissue-binding constant, intrinsic clearance, partition ratio of influx (k(in)) and efflux rate constant (k(out)), and k(in)/k(out) were related to physicochemical properties of drug (log P-app or pK(a)) and liver histopathology (FI, MP, or P450). In addition, hepatocyte organelle ion trapping of cationic drugs was evident in all groups. It is concluded that fibrosis-inducing hepatic disease effects on cationic drug disposition in the liver may be predicted from drug properties and liver histopathology.
Resumo:
Fixed-point roundoff noise in digital implementation of linear systems arises due to overflow, quantization of coefficients and input signals, and arithmetical errors. In uniform white-noise models, the last two types of roundoff errors are regarded as uniformly distributed independent random vectors on cubes of suitable size. For input signal quantization errors, the heuristic model is justified by a quantization theorem, which cannot be directly applied to arithmetical errors due to the complicated input-dependence of errors. The complete uniform white-noise model is shown to be valid in the sense of weak convergence of probabilistic measures as the lattice step tends to zero if the matrices of realization of the system in the state space satisfy certain nonresonance conditions and the finite-dimensional distributions of the input signal are absolutely continuous.
Resumo:
This present study was undertaken to assess potential effects of cadmium on CYP4A11 apoprotein in human liver and kidney as detected by Western blotting using a highly specific anti-peptide antibody. Liver and kidney cortex samples were autopsy specimens of 37 individuals (26 mates and I I females) whose ages ranged from 3 to 89 years. All were Caucasians who had not been exposed to cadmium in the workplace. Reduced CYP4A11 apoprotein levels were found in chronic hepatitis samples and in liver samples showing fatty changes. In contrast, increased CYP4A11 apoprotein levels were found in liver samples having higher cadmium content compared to the lower cadmium content samples. Increased CYP4A11 levels were also found in liver samples from female donors, compared to male donors; the difference being attributable to higher female liver cadmium burden. In distinction to liver, lowered CYP4A11 levels were seen in the kidney cortex samples which have high cadmium content, It is proposed here that the difference between the absolute cadmium burden of the liver and kidney samples may be responsible for the different patterns of expression of CYP4A11 in these two tissues. Further, since cadmium exposure may be associated with derangement in blood pressure control, it is interesting to note the possible relationship between altered CYP4A11-dependent production of arachidonic acid hydroxy and epoxy metabolites in kidney cortex and altered control of blood pressure. Our findings provide a possible link between these observations. (C) 2002 Elsevier Science Inc. All rights reserved.
Resumo:
The aim of this study was to review the published literature values for the selenium content of Australian foods. A secondary aim was to compare the results for Australian foods with food composition data from international sources to investigate the extent of geographical variation. Published food composition data sources for the selenium content in Australian foods were identified and assessed for data quality using established criteria. The selenium content is available for 148 individual food items. The highest values found are for fish (12.0-63.2 mug/100 g), meats (4.75-37.9 mug/100 g) and eggs (9.00-41.4 mug/100 g), followed by cereals (1.00-20.3 mug/100 g). Moderate levels are seen in dairy products (2.00-7.89 mug/100 g) while most fruits and vegetables have low levels (trace-3.27 mug/100 g). High selenium foods show the greatest level of geographical variation, with foods from the United States generally having higher selenium levels than Australian foods and foods from the United Kingdom and New Zealand having lower levels. This is the first attempt to review the available literature for selenium composition of Australian foods. These data serve as an interim measure for the assessment of selenium intake for use in epidemiological studies of diet-disease relationships. (C) 2002 Published by Elsevier Science Ltd.
Resumo:
Quantification of calcium in the cuticle of the fly larva Exeretonevra angustifrons was undertaken at the micron scale using wavelength dispersive X-ray microanalysis, analytical standards, and a full matrix correction. Calcium and phosphorus were found to be present in the exoskeleton in a ratio that indicates amorphous calcium phosphate. This was confirmed through electron diffraction of the calcium-containing tissue. Due to the pragmatic difficulties of measuring light elements, it is not uncommon in the field of entomology to neglect the use of matrix corrections when performing microanalysis of bulk insect specimens. To determine, firstly, whether such a strategy affects the outcome and secondly, which matrix correction is preferable, phi-rho (z) and ZAF matrix corrections were contrasted with each other and without matrix correction. The best estimate of the mineral phase was found to be given by using the phi-rho (z) correction. When no correction was made, the ratio of Ca to P fell outside the range for amorphous calcium phosphate, possibly leading to flawed interpretation of the mineral form when used on its own.
Resumo:
Low concentrate density from wet drum magnetic separators in dense medium circuits can cause operating difficulties due to inability to obtain the required circulating medium density and, indirectly, high medium solids losses. The literature is almost silent on the processes controlling concentrate density. However, the common name for the region through which concentrate is discharged-the squeeze pan gap-implies that some extrusion process is thought to be at work. There is no model of magnetics recovery in a wet drum magnetic separator, which includes as inputs all significant machine and operating variables. A series of trials, in both factorial experiments and in single variable experiments, was done using a purpose built rig which featured a small industrial scale (700 mm lip length, 900 turn diameter) wet drum magnetic separator. A substantial data set of 191 trials was generated in this work. The results of the factorial experiments were used to identify the variables having a significant effect on magnetics recovery. It is proposed, based both on the experimental observations of the present work and on observations reported in the literature, that the process controlling magnetic separator concentrate density is one of drainage. Such a process should be able to be defined by an initial moisture, a drainage rate and a drainage time, the latter being defined by the volumetric flowrate and the volume within the drainage zone. The magnetics can be characterised by an experimentally derived ultimate drainage moisture. A model based on these concepts and containing adjustable parameters was developed. This model was then fitted to a randomly chosen 80% of the data, and validated by application to the remaining 20%. The model is shown to be a good fit to data over concentrate solids content values from 40% solids to 80% solids and for both magnetite and ferrosilicon feeds. (C) 2003 Elsevier Science B.V. All rights reserved.
Resumo:
Movies, pieces of music, books, or newspapers can all be expressed in the same binary code. Discrete forms of analogue media are just different dialects of the language of computerese. Content is becoming a very liquid asset. To take Marshall McLuhan's famed dictum a step further: The message is now independent of the medium