44 resultados para photoelectronic device
Resumo:
A quantum Markovian master equation is derived to describe the current noise in resonant tunneling devices. This equation includes both incoherent and coherent quantum tunneling processes. We show how to obtain the population master equation by adiabatic elimination of quantum coherences in the presence of elastic scattering. We calculate the noise spectrum for a double well device and predict subshot noise statistics for strong tunneling between the wells. The method is an alternative to Green's function methods and population master equations for very small coherently coupled quantum dots.
Resumo:
Poor root development due to constraining soil conditions could be an important factor influencing health of urban trees. Therefore, there is a need for efficient techniques to analyze the spatial distribution of tree roots. An analytical procedure for describing tree rooting patterns from X-ray computed tomography (CT) data is described and illustrated. Large irregularly shaped specimens of undisturbed sandy soil were sampled from Various positions around the base of trees using field impregnation with epoxy resin, to stabilize the cohesionless soil. Cores approximately 200 mm in diameter by 500 mm in height were extracted from these specimens. These large core samples were scanned with a medical X-ray CT device, and contiguous images of soil slices (2 mm thick) were thus produced. X-ray CT images are regarded as regularly-spaced sections through the soil although they are not actual 2D sections but matrices of voxels similar to 0.5 mm x 0.5 mm x 2 mm. The images were used to generate the equivalent of horizontal root contact maps from which three-dimensional objects, assumed to be roots, were reconstructed. The resulting connected objects were used to derive indices of the spatial organization of roots, namely: root length distribution, root length density, root growth angle distribution, root spatial distribution, and branching intensity. The successive steps of the method, from sampling to generation of indices of tree root organization, are illustrated through a case study examining rooting patterns of valuable urban trees. (C) 1999 Elsevier Science B.V. All rights reserved.
Resumo:
We propose a single optical photon source for quantum cryptography based on the acoustoelectric effect. Surface acoustic waves (SAWs) propagating through a quasi-one-dimensional channel have been shown to produce packets of electrons that reside in the SAW minima and travel at the velocity of sound. In our scheme, the electron packets are injected into a p-type region, resulting in photon emission. Since the number of electrons in each packet can be controlled down to a single electron, a stream of single- (or N-) photon states, with a creation time strongly correlated with the driving acoustic field, should be generated.
The Las Campanas/AAT rich cluster survey - I. Precision and reliability of the photometric catalogue
Resumo:
The Las Campanas Observatory and Anglo-Australian Telescope Rich Cluster Survey (LARCS) is a panoramic imaging and spectroscopic survey of an X-ray luminosity-selected sample of 21 clusters of galaxies at 0.07 < z < 0.16. Charge-coupled device (CCD) imaging was obtained in B and R of typically 2 degrees wide regions centred on the 21 clusters, and the galaxy sample selected from the imaging is being used for an on-going spectroscopic survey of the clusters with the 2dF spectrograph on the Anglo-Australian Telescope. This paper presents the reduction of the imaging data and the photometric analysis used in the survey. Based on an overlapping area of 12.3 deg(2) we compare the CCD-based LARCS catalogue with the photographic-based galaxy catalogue used for the input to the 2dF Galaxy Redshift Survey (2dFGRS) from the APM, to the completeness of the GRS/APM catalogue, b(J) = 19.45. This comparison confirms the reliability of the photometry across our mosaics and between the clusters in our survey. This comparison also provides useful information concerning the properties of the GRS/APM. The stellar contamination in the GRS/APM galaxy catalogue is confirmed as around 5-10 per cent, as originally estimated. However, using the superior sensitivity and spatial resolution in the LARCS survey evidence is found for four distinct populations of galaxies that are systematically omitted from the GRS/APM catalogue. The characteristics of the 'missing' galaxy populations are described, reasons for their absence examined and the impact they will have on the conclusions drawn from the 2dF Galaxy Redshift Survey are discussed.
Resumo:
We are currently in the midst of a second quantum revolution. The first quantum revolution gave us new rules that govern physical reality. The second quantum revolution will take these rules and use them to develop new technologies. In this review we discuss the principles upon which quantum technology is based and the tools required to develop it. We discuss a number of examples of research programs that could deliver quantum technologies in coming decades including: quantum information technology, quantum electromechanical systems, coherent quantum electronics, quantum optics and coherent matter technology.
Resumo:
This study examined the impact of computer and assistive device use on the employment status and vocational modes of people with physical disabilities in Australia. A survey was distributed to people over 15 years in age with physical disabilities living in the Brisbane area. Responses were received from 82 people, including those with spinal cord injuries, cerebral palsy and muscular dystrophy. Of respondents 46 were employed, 22 were unemployed, and 12 were either students or undertaking voluntary work. Three-quarters of respondents used a computer in their occupations, while 15 used assistive devices. Using logistic regression analysis it was found that gender, education, level of computer skill and computer training were significant predictors of employment outcomes. Neither the age of respondent nor use of assistive software were significant predictors. From information obtained in this study guidelines for a training programme designed to maximize the employability of people with physical disabilities were developed.
Resumo:
HE PROBIT MODEL IS A POPULAR DEVICE for explaining binary choice decisions in econometrics. It has been used to describe choices such as labor force participation, travel mode, home ownership, and type of education. These and many more examples can be found in papers by Amemiya (1981) and Maddala (1983). Given the contribution of economics towards explaining such choices, and given the nature of data that are collected, prior information on the relationship between a choice probability and several explanatory variables frequently exists. Bayesian inference is a convenient vehicle for including such prior information. Given the increasing popularity of Bayesian inference it is useful to ask whether inferences from a probit model are sensitive to a choice between Bayesian and sampling theory techniques. Of interest is the sensitivity of inference on coefficients, probabilities, and elasticities. We consider these issues in a model designed to explain choice between fixed and variable interest rate mortgages. Two Bayesian priors are employed: a uniform prior on the coefficients, designed to be noninformative for the coefficients, and an inequality restricted prior on the signs of the coefficients. We often know, a priori, whether increasing the value of a particular explanatory variable will have a positive or negative effect on a choice probability. This knowledge can be captured by using a prior probability density function (pdf) that is truncated to be positive or negative. Thus, three sets of results are compared:those from maximum likelihood (ML) estimation, those from Bayesian estimation with an unrestricted uniform prior on the coefficients, and those from Bayesian estimation with a uniform prior truncated to accommodate inequality restrictions on the coefficients.
Resumo:
Study Design. A comparative study of cervical range of motion in asymptomatic persons and those with whiplash. Objectives. To compare the primary and conjunct ranges of motion of the cervical spine in asymptomatic persons and those with persistent whiplash-associated disorders, and to investigate the ability of these measures of range of motion to discriminate between the groups. Summary of Background. Evidence that range of motion is an effective indicator of physical impairment in the cervical spine is not conclusive. Few studies have evaluated the ability to discriminate between asymptomatic persons and those with whiplash on the basis of range of motion or compared three-dimensional in vivo measures of range of motion in asymptomatic persons and those with whiplash-associated disorders. Methods. The study participants were 89 asymptomatic volunteers (41 men, 48 women; mean age 39.2 years) and 114 patients with persistent whiplash-associated disorders (22 men, 93 women; mean age 37.2 years) referred to a whiplash research unit for assessment of their cervical region. Range of cervical motion was measured in three dimensions with a computerized, electromagnetic, motion-tracking device. The movements assessed were flexion, extension, left and right lateral flexion, and left and right rotation. Results. Range of motion was reduced in all primary movements in patients with persistent whiplash-associated disorder. Sagittal plane movements were proportionally the most affected. On the basis of primary and conjunct range of motion, age, and gender, 90.3% of study participants could be correctly categorized as asymptomatic or as having whiplash (sensitivity 86.2%, specificity 95.3%). Conclusions. Range of motion was capable of discriminating between asymptomatic persons and those with persistent whiplash-associated disorders.
Resumo:
Rectangular piezoceramic transducers are widely used in ultrasonic evaluation and health monitoring techniques and structural vibration control applications. In this paper the flexural waves excited by rectangular transducers adhesively attached to isotropic plates are investigated. In view of the difficulties in developing accurate analytical models describing the transfer characteristics of the transducer due to the complex electromechanical transduction processes and transducer-structure interactions involved, a combined theoretical-experimental approach is developed. A multiple integral transform method is used to describe the propagation behaviour of the waves in the plates, while a heterodyne Doppler laser vibrometer is employed as a non-contact receiver device. This combined theoretical-experimental approach enables the efficient characterization of the electromechanical transfer properties of the piezoelectric transducer which is essential for the development of optimized non-destructive evaluation systems. The results show that the assumption of a uniform contact pressure distribution between the transducer and the plate can accurately predict the frequency spectrum and time domain response signals of the propagating waves along the main axes of the rectangular transmitter element.
Resumo:
Objective: To assess the appropriateness of ipratropium bromide prescribing in two tertiary referral hospitals. Method: Criteria for optimal use were developed based on current literature and modified after consultation with respiratory physicians and clinical pharmacists. A prospective review of prescribing was performed over a 2-month period to assess conformity to these criteria. Results: Information was collected from 84 patients; 5% were receiving inhalers and 96% nebuliser therapy (one patient used both). 77% of patients (n = 65) had a principal diagnosis of chronic obstructive pulmonary disease, 14% (n = 12) asthma and 8% (n = 7) had neither diagnosis. 75% of patients were using ipratropium outside the guidelines. The major areas where the guidelines were not met were a lack of therapeutic justification, use of inappropriate doses, and use of an inappropriate delivery device. Feedback and educational interventions were designed and delivered based on the data obtained. Conclusions: There was widespread use of ipratropium outside the developed guidelines. Interventions in specific areas could lead to significant improvements in the use of this high cost drug
Resumo:
The quasi mode theory of macroscopic quantization in quantum optics and cavity QED developed by Dalton, Barnett and Knight is generalized. This generalization allows for cases in which two or more quasi permittivities, along with their associated mode functions, are needed to describe the classical optics device. It brings problems such as reflection and refraction at a dielectric boundary, the linear coupler, and the coupling of two optical cavities within the scope of the theory. For the most part, the results that are obtained here are simple generalizations of those obtained in previous work. However the coupling constants, which are of great importance in applications of the theory, are shown to contain significant additional terms which cannot be 'guessed' from the simpler forms. The expressions for the coupling constants suggest that the critical factor in determining the strength of coupling between a pair of quasi modes is their degree of spatial overlap. In an accompanying paper a fully quantum theoretic derivation of the laws of reflection and refraction at a boundary is given as an illustration of the generalized theory. The quasi mode picture of this process involves the annihilation of a photon travelling in the incident region quasi mode, and the subsequent creation of a photon in either the incident region or transmitted region quasi modes.
Resumo:
It has been previously demonstrated that aspartic, serine, metallo and cysteine proteases bind to their inhibitors and substrate analogues in a single conformation, the saw-tooth or extended beta-strand. Consequently a generic approach to the development of protease inhibitors is the use of constraints that conformationally restrict putative inhibitor molecules to an extended form. In this way the inhibitor is pre-organized for binding to a protease and does not need to rearrange its structure. One constraining device that has proven to be effective for such pre-organization is macrocyclization. This article illustrates the general principle that macrocycles, especially those composed of 3-4 amino acids and usually 13-17 ring atoms, can effectively mimic the extended conformation of short peptide sequences. Such structure-stabilising macrocycles are stable to degradation by proteases, valuable components of potent protease inhibitors, and in many cases they are also bioavailable.
Resumo:
We obtain the finite-temperature unconditional master equation of the density matrix for two coupled quantum dots (CQD's) when one dot is subjected to a measurement of its electron occupation number using a point contact (PC). To determine how the CQD system state depends on the actual current through the PC device, we use the so-called quantum trajectory method to derive the zero-temperature conditional master equation. We first treat the electron tunneling through the PC barrier as a classical stochastic point process (a quantum-jump model). Then we show explicitly that our results can be extended to the quantum-diffusive limit when the average electron tunneling rate is very large compared to the extra change of the tunneling rate due to the presence of the electron in the dot closer to the PC. We find that in both quantum-jump and quantum-diffusive cases, the conditional dynamics of the CQD system can be described by the stochastic Schrodinger equations for its conditioned state vector if and only if the information carried away from the CQD system by the PC reservoirs can be recovered by the perfect detection of the measurements.
Resumo:
Expansion tubes operating at total flow enthalpies of 100 MJ kg(-1) or more have characteristical test times of 30-50 mus. Under these conditions, the response time of the Pitot pressure measuring device is critical when performing flow calibration studies. The conventional technique of using a commercial pressure transducer protected by shielding has not always proven to be effective, due to the relatively large (and variable) response time caused by the shielding. A device called the stress wave bar gauge has been designed and calibrated and shown to be an effective way to measure the Pitot pressure with a response time of only 2-3 mus.