188 resultados para performance measuring
Resumo:
An extension of a previous study of age and sex effects on verbal recall (Geffen, Moar, O'Hanlon, lark, & Geffen, 1990) examined forgetting of words over extended delays. The AVLT was administered to 201 normal adults (99 males, 102 females) ranging in age between 20 and 59 years. Recall was tested at intervals of 30 minutes, 24 hours, and 7 days after acquisition. Testing of the latter two intervals was conducted by telephone (Experiment 1, N = 177). After 30 minutes there was no significant loss of the 10 to 11 words retained from five acquisition trials. However, an overall mean of about one word was forgotten after 1 day and a further word after 7 days. The oldest age group (50-59 years) acquired fewer words and forgot more words than the younger groups. Females of all age groups performed slightly better than males at acquisition, at retention, and at recall after longer delays. A second experiment showed that telephone testing at the longer delay intervals was equivalent to testing face to face. These results extend the use of the AVLT by assessing memory decay beyond the immediate testing period. Telephone follow-up is a convenient and economical method of testing delayed recall.
Resumo:
A sensitive and reproducible solid-phase extraction (SPE) method for the quantification of oxycodone in human plasma was developed. Varian Certify SPE cartridges containing both C-8 and benzoic acid functional groups were the most suitable for the extraction of oxycodone and codeine (internal standard), with consistently high (greater than or equal to 80%) and reproducible recoveries. The elution mobile phase consisted of 1.2 ml of butyl chloride-isopropanol (80:20, v/v) containing 2% ammonia. The quantification limit for oxycodone was 5.3 pmol on-column. Within-day and inter-day coefficients of variation were 1.2% and 6.8% respectively for 284 nM oxycodone and 9.5% and 6.2% respectively for 28.4 nM oxycodone using 0.5-ml plasma aliquots. (C) 1998 Elsevier Science BN. All rights reserved.
Resumo:
Purpose: The relationship between six descriptors of lactate increase, peak (V) over dot O-2,W-peak, and 1-h cycling performance were compared in 24 trained, female cyclists (peak (V) over dot O-2 = 48.11 +/- 6.32 mL . kg(-1) . min(-1)). Methods: The six descriptors of lactate increase were: 1) lactate threshold (LT; the power output at which plasma lactate concentration begins to increase above the resting level during an incremental exercise test), 2) LT1 (the power output at which plasma lactate increases by 1 mM or more), 3) LTD (the lactate threshold calculated by the D-max method), 4) LTMOD (the lactate threshold calculated by a modified D-max method), 5) L4 (the power output at which plasma lactate reaches a concentration of 4 mmol-L-1), and 6) LTLOG (the power output at which plasma lactate concentration begins to increase when the log([La-]) is plotted against the log (power output)). Subjects first completed a peak (V) over dot O-2 test on a cycle ergometer. Finger-tip capillary blood was sampled within 30 s of the end of each 3-min stage for analysis of plasma lactate. Endurance performance was assessed 7 d later using a 1-h cycle test (OHT) in which subjects were directed to achieve the highest possible average power output. Results: The mean power output (W) for the OHT (+/- SD) was 183.01 +/- 18.88, and for each lactate variable was: LT (138.54 +/- 46.61), LT1 (179.17 +/- 27.25), LTLOG (143.97 +/- 45.74), L4 (198.09 +/- 33.84), LTD (178.79 +/- 24.07), LTMOD (212.28 +/- 31.75). Average power output during the OHT was more strongly correlated with all plasma lactate parameters (0.61 < r < 0.84) and W-peak (r = 0.81) than with peak (V) over dot O-2 (r = 0.55). The six lactate parameters were strongly correlated with each other (0.54 < r < 0.91) and of the six lactate parameters, LTD correlated best with endurance performance (r = 0.84). Conclusions: It was concluded that plasma lactate parameters and W-peak provide better indices of endurance performance than peak (V) over dot O-2 and that, of the six descriptors of lactate increase measured in this study, LTD is most strongly related to 1-h cycling performance in trained, female cyclists.
Resumo:
Using survey data for Tongan and Samoan migrants in Sydney the effects of visa restrictions on labor market performance of migrants are assessed. Univariate analysis suggests a positive association between unemployment and the unrestricted entry of Samoan step-migrants from New Zealand. A probit model of the determinants of unemployment is estimated with controls for human capital and demographic variables. While human capital endowments are important, visa restrictions do not have a significant effect on either group's employability. Implications for policy are discussed highlighting the complementarities between host country immigration policies and foreign aid programs.
Resumo:
1, Studies of evolutionary temperature adaptation of muscle and locomotor performance in fish are reviewed with a focus on the Antarctic fauna living at subzero temperatures. 2. Only limited data are available to compare the sustained and burst swimming kinematics and performance of Antarctic, temperate and tropical species. Available data indicate that low temperatures limit maximum swimming performance and this is especially evident in fish larvae. 3, In a recent study, muscle performance in the Antarctic rock cod Notothenia coriiceps at 0 degrees C was found to be sufficient to produce maximum velocities during burst swimming that were similar to those seen in the sculpin Myoxocephalus scorpius at 10 degrees C, indicating temperature compensation of muscle and locomotor performance in the Antarctic fish. However, at 15 degrees C, sculpin produce maximum swimming velocities greater than N, coriiceps at 0 degrees C, 4, It is recommended that strict hypothesis-driven investigations using ecologically relevant measures of performance are undertaken to study temperature adaptation in Antarctic fish, Recent detailed phylogenetic analyses of the Antarctic fish fauna and their temperate relatives will allow a stronger experimental approach by helping to separate what is due to adaptation to the cold and what is due to phylogeny alone.
Resumo:
The present study examined the effects of work control and job demands on employee adjustment and work performance using a multidimensional measure of work control (assessing levels of task control, decision control and work scheduling control). It was proposed that the negative effects of job demands and employee adjustment would be moderated by high levels of task control. It was also proposed that there would be evidence of main effects of both job demands and work control (particularly task-related levels of control) on employee adjustment. To test these predictions, a study of 135 university employees holding administrative positions was undertaken. Methodological improvements over previous research included the use of both self-reported adjustment measures and supervisor ratings of work performance as outcome variables, and the assessment of the predictor and outcome measures at different points in time (self-reported adjustment was assessed at both Times 1 and 2). The results revealed some support for the proposal that the effects of job demands would be buffered by high levels of task control, but not more peripheral aspects of work control. There were also significant main effects of task control on job satisfaction.
Resumo:
A simple method for the measurement of pindolol enantiomers by HPLC is presented. Alkalinized serum or urine is extracted with ethyl acetate and the residue remaining after evaporation of the organic layer is then derivatised with (S)-(-)-alpha-methylbenzyl isocyanate. The diastereoisomers of derivatised pindolol and metoprolol (internal standard) are separated by high-performance liquid chromatography (HPLC) using a C-18 silica column and detected using fluorescence (excitation lambda: 215 nm, emission lambda: 320 nm). The assay displays reproducible linearity for pindolol enantiomers with a correlation coefficient of r(2) greater than or equal to 0.998 over the concentration range 8-100 ng ml(-1) for plasma and 0.1-2.5 mu g ml(-1) for urine. The coefficient of variation for accuracy and precision of the quality control samples for both plasma and urine are consistently
Resumo:
Mycophenolic acid is an immunosuppressant administered as a bioavailable ester, mycophenolate mofetil. The pharmacokinetics of mycophenolic acid have been reported to be variable. Accurate measurement of concentrations of this drug could be important to adjust doses. The aim of this study was to compare the enzyme-multiplied immunoassay technique (EMIT [Dade Behring; San Jose, CA, U.S.A.]) for mycophenolic acid with a high-performance liquid chromatographic (HPLC) assay using samples collected from renal transplant recipients. The HPLC assay used solid phase extraction and a C18 stationary phase with ultraviolet (UV) detection (254 nm). The immunoassay required no manual sample preparation. Plasma samples (n = 102) from seven patients, collected at various times after a dose, were analyzed using both methods. Both assays fulfilled quality-control criteria. Higher concentrations were consistently measured in patient samples when using EMIT. The mean (+/- standard deviation [SD]) bias (EMIT-HPLC) was 1.88 +/- 0.86 mg/L. The differences in concentrations were higher in the middle of a dosage interval, suggesting that a metabolite might have been responsible for overestimation. Measurement of glucuronide concentrations by HPLC demonstrated only a weak correlation between assay differences and glucuronide concentrations. If the crossreacting substance is active, EMIT could provide a superior measure of immunosuppression; if inactive, further work is needed to improve antibody specificity. In conclusion, it was found that EMIT overestimates the concentration of mycophenolic acid in plasma samples from renal transplant recipients compared with HPLC analysis.
Resumo:
The corrosion behaviour of AZ21, AZ501 and AZ91 was studied in 1 N NaCl at pH 11 by measuring electrochemical polarization curves, electrochemical AC impedance spectroscopy (EIS) and simultaneously measuring the hydrogen evolution rate and the: magnesium dissolution rate. The corrosion rates increased in the following order: AZ501 < AZ21 < AZ91. The: corrosion behaviour was related to alloy microstructure as revealed by optical and electron microscopy. The beta phase was very stable in the test solution and was an effective cathode. The beta phase served two roles, as a barrier and as a galvanic cathode. If the beta phase is present in the alpha matrix as intergranular precipitates with a small volume fraction, then the beta phase mainly serves as a galvanic cathode, and accelerates the corrosion of the alpha matrix. If the beta Fraction is high, then the beta phase may mainly act as an anodic barrier to inhibit the overall corrosion of the alloy. The composition and compositional distribution in the alpha phase is also crucial to the overall corrosion performance of dual phase alloys. Increasing the aluminum concentration in the alpha phase increases the anodic dissolution rate and also increases the cathodic hydrogen evolution rate. Increasing the zinc concentration in the alpha phase may have the opposite effect. (C) 1998 Elsevier Science Ltd. All rights reserved.
Resumo:
The corrosion of die cast AZ91D was studied and related to its microstructure. For comparison and to more fully understand the behaviour of die cast AZ91D, corrosion studies and microstructural examinations were also carried out using slowly solidified high purity AZ91, Mg-2%Al, Mg-9%Al, low purity magnesium and high purity magnesium. Corrosion was studied in 1N NaCl at pH 11 by (1) observing the corrosion morphology, (2) measuring electrochemical polarisation curves and (3) simultaneously measuring both the hydrogen evolution rate and the magnesium dissolution rate. The skin of die cast AZ91D showed better corrosion resistance than the interior. This is attributed to a combination of(1) a higher volume fraction of the beta phase, (2) a more continuous beta phase distribution around finer alpha grains, and (3) lower porosity in the skin layer than in the interior of the die casting. This study showed that the casting method can influence the corrosion performance by its influence on the alloy microstructure. (C) 1999 Elsevier Science Ltd. All rights reserved.
Resumo:
High performance composite membranes based on molecular sieving silica (MSS) were synthesized using sols containing silicon co-polymers (methyltriethoxysilane and tetraethylorthosilicate). Alpha alumina supports were treated with hydrochloric acid prior to sol deposition. Permselectivity of CO2 over CH4 as high as 16.68 was achieved whilst permeability of CO2 up to 36.7 GPU (10(-6) cm(3) (STP) cm(-2) . s(-1) . cm Hg-1) was measured. The best membrane's permeability was finger printed during various stages of the synthesis process showing an increase in CO2/CH4 permselectivity by over 25 times from initial support condition (no membrane film) to the completion of pore structure tailoring. Transport measurement results indicate that the membrane pretreated with HCl has highest permselectivity and permeation rate. In particular, there is a definite cut-off pore size between 3.3 and 3.4 angstroms which is just below the kinetic diameters of Ar and CH4. This demonstrates that the mechanism for the separation in the prepared composite membrane is molecular sieving (activated diffusion), rather than Knudsen diffusion.
Resumo:
Previous analyses of thermal acclimation of locomotor performance in amphibians have only examined the adult life history stage and indicate that the locomotor system is unable to undergo acclimatory changes to temperature. In this study, we examined the ability of tadpoles of the striped marsh frog (Limnodynastes peronii) to acclimate their locomotor system by exposing them to either 10 degrees C or 24 degrees C for 6 weeks and testing their burst swimming performance at 10, 24, and 34 degrees C. At the test temperature of 10 degrees C, maximum velocity (U-max) of the 10 degrees C-acclimated tadpoles was 47% greater and maximum acceleration (A(max)) 53% greater than the 24 degrees C-acclimated animals. At 24 degrees C, U-max was 16% greater in the 10 degrees C-acclimation group, while there was no significant difference in A(max) or the time taken to reach U-max (T-U-max). At 34 degrees C, there was no difference between the acclimation groups in either U-max or A(max), however T-U-max was 36% faster in the 24 degrees C-acclimation group. This is the first study to report an amphibian (larva or adult) possessing the capacity to compensate for cool temperatures by thermal acclimation of locomotor performance. To determine whether acclimation period affected the magnitude of the acclimatory response, we also acclimated tadpoles of L. peronii to 10 degrees C for 8 months and compared their swimming performance with tadpoles acclimated to 10 degrees C for 6 weeks. At the test temperatures of 24 degrees C and 34 degrees C, U-max and A(max) were significantly slower in the tadpoles acclimated to 10 degrees C for 8 months. At 10 degrees C, T-U-max was 40% faster in the 8-month group, while there were no differences in either U-max or A(max). Although locomotor performance was enhanced at 10 degrees C by a longer acclimation period, this was at the expense of performance at higher temperatures.
Resumo:
The aim of this study was to establish the effect that pre-cooling the skin without a concomitant reduction in core temperature has on subsequent self-paced cycling performance under warm humid (31 degrees C and 60% relative humidity) conditions. Seven moderately trained males performed a 30 min self-paced cycling trial on two separate occasions. The conditions were counterbalanced as control or whole-body pre-cooling by water immersion so that resting skin temperature was reduced by approximate to 5-6 degrees C. After pre-cooling, mean skin temperature was lower throughout exercise and rectal temperature was lower (P < 0.05) between 15 and 25 min of exercise. Consequently, heat storage increased (P < 0.003) from 84.0 +/- 8.8 W . m(-2) to 153 +/- 13.1 W . m(-2) (mean +/- s((x) over bar)) after pre-cooling, while total body sweat fell from 1.7 +/- 0.1 1 . h(-1) to 1.2 +/- 0.1 1 . h(-1) (P < 0.05). The distance cycled increased from 14.9 +/- 0.8 to 15.8 +/- 0.7 km (P < 0.05) after pre-cooling. The results indicate that skin pre-cooling in the absence of a reduced rectal temperature is effective in reducing thermal strain and increasing the distance cycled in 30 min under warm humid conditions.