89 resultados para Parameters estimation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We propose a simulated-annealing-based genetic algorithm for solving model parameter estimation problems. The algorithm incorporates advantages of both genetic algorithms and simulated annealing. Tests on computer-generated synthetic data that closely resemble optical constants of a metal were performed to compare the efficiency of plain genetic algorithms against the simulated-annealing-based genetic algorithms. These tests assess the ability of the algorithms to and the global minimum and the accuracy of values obtained for model parameters. Finally, the algorithm with the best performance is used to fit the model dielectric function to data for platinum and aluminum. (C) 1997 Optical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The open channel diameter of Escherichia coli recombinant large-conductance mechanosensitive ion channels (MscL) was estimated using the model of Hille (Hille, B. 1968. Pharmacological modifications of the sodium channels of frog nerve. J. Gen. Physiol. 51:199-219)that relates the pore size to conductance. Based on the MscL conductance of 3.8 nS, and assumed pore lengths, a channel diameter of 34 to 46 Angstrom was calculated. To estimate the pore size experimentally, the effect of large organic ions on the conductance of MscL was examined. Poly-L-lysines (PLLs) with a diameter of 37 Angstrom or larger significantly reduced channel conductance, whereas spermine (similar to 15 Angstrom), PLL19 (similar to 25 Angstrom) and 1,1'-bis-(3-(1'-methyl-(4,4'-bipyridinium)-1-yl)-propyl)-4,4'-bipyridinium (similar to 30 Angstrom) had no effect. The smaller organic ions putrescine, cadaverine, spermine, and succinate all permeated the channel. We conclude that the open pore diameter of the MscL is similar to 40 Angstrom, indicating that the MscL has one of the largest channel pores yet described. This channel diameter is consistent with the proposed homohexameric model of the MscL.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A dynamic modelling methodology, which combines on-line variable estimation and parameter identification with physical laws to form an adaptive model for rotary sugar drying processes, is developed in this paper. In contrast to the conventional rate-based models using empirical transfer coefficients, the heat and mass transfer rates are estimated by using on-line measurements in the new model. Furthermore, a set of improved sectional solid transport equations with localized parameters is developed in this work to reidentified on-line using measurement data, the model is able to closely track the dynamic behaviour of rotary drying processes within a broad range of operational conditions. This adaptive model is validated against experimental data obtained from a pilot-scale rotary sugar dryer. The proposed modelling methodology can be easily incorporated into nonlinear model based control schemes to form a unified modelling and control framework.place the global correlation for the computation of solid retention time. Since a number of key model variables and parameters are identified on-line using measurement data, the model is able to closely track the dynamic behaviour of rotary drying processes within a broad range of operational conditions. This adaptive model is validated against experimental data obtained from a pilot-scale rotary sugar dryer. The proposed modelling methodology can be easily incorporated into nonlinear model based control schemes to form a unified modelling and control framework.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Estimation of total body water by measuring bioelectrical impedance at a fixed frequency of 50 kHz is useful in assessing body composition in healthy populations. However, in cirrhosis, the distribution of total body water between the extracellular and intracellular compartments is of greater clinical importance. We report an evaluation of a new multiple-frequency bioelectrical-impedance analysis technique (MFBIA) that may quantify the distribution of total body water in cirrhosis. In 21 cirrhotic patients and 21 healthy control subjects, impedance to the Row of current was measured at frequencies ranging from 4 to 1012 kHz. These measurements were used to estimate body water compartments and then compared with total body water and extracellular water determined by isotope methodology. In cirrhotic patients, extracellular water and total body water (as determined by isotope methods) were well predicted by MFBIA (r = 0.73 and 0.89, respectively).;However, the 95% confidence intervals of the limits of agreement between MFBIA and the isotope methods were +/- 14% and +/-9% for cirrhotics (extracellular water and total body water, respectively) and +/-9% and +/-9% for cirrhotics without ascites. The 95% confidence intervals estimated from the control group were +/-10% and +/-5% for extracellular water and total body water, respectively. Thus, despite strong correlations between MFBIA and isotope measurements, the relatively large limits of agreement with accepted techniques suggest that the MFBIA technique requires further refinement before it can be routinely used to determine the nutritional assessment of individual cirrhotic patients. Nutrition 2001,17.31-34. (C)Elsevier Science Inc. 2001.

Relevância:

20.00% 20.00%

Publicador: