106 resultados para Measurement errors
Resumo:
We outline a scheme to accomplish measurements of a solid state double well system (DWS) with both one and two electrons in nonlocalized bases. We show that, for a single particle, measuring the local charge distribution at the midpoint of a DWS using a SET as a sensitive electrometer amounts to performing a projective measurement in the parity (symmetric/antisymmetric) eigenbasis. For two-electrons in a DWS, a similar configuration of SET results in close-to-projective measurement in the singlet/triplet basis. We analyze the sensitivity of the scheme to asymmetry in the SET position for some experimentally relevant parameter, and show that it is experimentally realizable.
Resumo:
We generalize a proposal for detecting single-phonon transitions in a single nanoelectromechanical system (NEMS) to include the intrinsic anharmonicity of each mechanical oscillator. In this scheme two NEMS oscillators are coupled via a term quadratic in the amplitude of oscillation for each oscillator. One NEMS oscillator is driven and strongly damped and becomes a transducer for phonon number in the other measured oscillator. We derive the conditions for this measurement scheme to be quantum limited and find a condition on the size of the anharmonicity. We also derive the relation between the phase diffusion back-action noise due to number measurement and the localization time for the measured system to enter a phonon-number eigenstate. We relate both these time scales to the strength of the measured signal, which is an induced current proportional to the position of the read-out oscillator.
Resumo:
A measure of dimensional anxiety specifically designed for use in older people is urgently needed. Such a measure could be used in a variety of settings to screen for anxiety disorders and to measure response to treatment in older people with established anxiety disorders. We have developed a new instrument to measure generalized anxiety symptoms in older people, the Geriatric Anxiety Inventory (GAI). This new instrument uses plain language, minimises somatic items and has a dichotomous response scale. Although it is a self-report measure, it may readily be administered to frail and mildly cognitively impaired older people by nursing staff. The development and initial validation of the GAI will be described. The scale was administered to community samples as well as patients with anxiety, depression, and mild cognitive impairment. Reliability was high and validity sound when compared to a range of standard anxiety instruments, and the instrument was well-tolerated among these cohorts. Sensitivity, specificity and cut-off scores for community and impatient samples will be presented.
Resumo:
Traumatic brain injury (TBI) may result in a variety of cognitive, behavioural and physical impairments. Dizziness has been reported in up to 80% of cases within the first few days after injury. The literature was reviewed to attempt to delineate prevalence of dizziness as a symptom, impairments causing dizziness, the functional limitations it causes and its measurement. The literature provides widely differing estimates of prevalence and vestibular system dysfunction appears to be the best reported of impairments contributing to this symptom. The variety of results is discussed and other possible causes for dizziness were reviewed. Functional difficulties caused by dizziness were not reported for this population in the literature and review of cognitive impairments suggests that existing measurement tools for dizziness may be problematic in this population. Research on the functional impact of dizziness in the TBI population and measurement of these symptoms appears to be warranted.
Resumo:
Piezoelectric polymers have been used to form the basis of dynamic strain gauges for the detection of stress waves. The linearity of response was tested using a split Hopkinson pressure bar arrangement. The results obtained illustrate the effectiveness of piezoelectric film strain gauges in the measurement of axial stress waves.
Resumo:
A single-beam gradient trap could potentially be used to hold a stylus for scanning force microscopy. With a view to development of this technique, we modeled the optical trap as a harmonic oscillator and therefore characterized it by its force constant. We measured force constants and resonant frequencies for 1-4-mu m-diameter polystyrene spheres in a single-beam gradient trap using measurements of back-scattered light. Force constants were determined with both Gaussian and doughnut laser modes, with powers of 3 and 1 mW, respectively. Typical values for spring constants were measured to be between 10(-6) and 4 x 10(-6) N/m. The resonant frequencies of trapped particles were measured to be between 1 and 10 kHz, and the rms amplitudes of oscillations were estimated to be around 40 nm. Our results confirm that the use of the doughnut mode for single-beam trapping is more efficient in the axial direction. (C) 1996 Optical Society of America.
Resumo:
The technical reliability (i.e., interinstrument and interoperator reliability) of three SEAC-swept frequency bioimpedance monitors was assessed for both errors of measurement and associated analyses. In addition, intraoperator and intrainstrument variability was evaluated for repeat measures over a 4-hour period. The measured impedance values from a range of resistance-capacitance circuits were accurate to within 3% of theoretical values over a range of 50-800 ohms. Similarly, phase was measured over the range 1 degrees-19 degrees with a maximum deviation of 1.3 degrees from the theoretical value. The extrapolated impedance at zero frequency was equally well determined (+/-3%). However, the accuracy of the extrapolated value at infinite frequency was decreased, particularly at impedances below 50 ohms (approaching the lower limit of the measurement range of the instrument). The interinstrument/operator variation for whole body measurements were recorded on human volunteers with biases of less than +/-1% for measured impedance values and less than 3% for phase. The variation in the extrapolated values of impedance at zero and infinite frequencies included variations due to operator choice of the analysis parameters but was still less than +/-0.5%. (C) 1997 Wiley-Liss, Inc.
Resumo:
In this paper use consider the problem of providing standard errors of the component means in normal mixture models fitted to univariate or multivariate data by maximum likelihood via the EM algorithm. Two methods of estimation of the standard errors are considered: the standard information-based method and the computationally-intensive bootstrap method. They are compared empirically by their application to three real data sets and by a small-scale Monte Carlo experiment.
Resumo:
The technique of frequency-resolved optical gating is used to characterize the intensity and the phase of picosecond pulses after propagation through 700 m of fiber at close to the zero-dispersion wavelength. Using the frequency-resolved optical gating technique, we directly measure the severe temporal distortion resulting from the interplay between self-phase modulation and higher-order dispersion in this regime. The measured intensity and phase of the pulses after propagation are found to be in good agreement with the predictions of numerical simulations with the nonlinear Schrodinger equation. (C) 1997 Optical Society of America.
Resumo:
Aims The excretion of phospholipids in urine may be a marker of the early renal toxicity of the aminoglycoside antibiotics. Urinary phospholipids are formed in myeloid bodies which develop in the lysosomes of proximal tubules during treatment with the aminoglycosides, and overflow into the urine. Methods Published assays were modified in order to measure the total phospholipid concentrations in human urine. Phospholipids were extracted from freeze-dried urine samples, digested in concentrated sulphuric acid, and the inorganic phosphorus content determined by complexing with ammonium molybdate and measuring the absorbance at 820 nm. Ten septicaemic patients treated with gentamicin for 5-7 days had significantly higher urine phospholipid concentrations than 10 healthy untreated control subjects (P<0.0001). There was a negative Linear relationship between phospholipid excretion and creatinine clearance (r(2) = 0.71). Results In 34 patients with acute pyelonephritis, increased phospholipid concentrations were observed prior to treatment compared with healthy controls (P<0.001) and did not alter during treatment with gentamicin. However, the phospholipid concentrations decreased significantly after treatment was completed (P<0.03). Conclusions These studies suggest that urinary phospholipids may indicate early aminoglycoside toxicity but with poor specificity, as many of the infections being treated may themselves be associated with phospholipiduria.
Resumo:
The aim of this study was to confirm that the radiation doses received by attendants who manually restrain infants during fluoroscopic procedures are low. Doses to the hands and neck of three radiologists and three nurses performing or assisting at all the fluoroscopic procedures in a children's hospital were measured for 1 month using thermoluminescent dosemeters. All fluoroscopy on children at this hospital is performed without an antiscatter grid. Total doses for the neck ranged from 20 to 50 mu Sv per week and for hands from 40 to 210 mu Sv per week. These doses were shared by the three radiologists and the three nurses. Individual doses received per staff member are very small when compared with the doses received by interventional radiology staff. Doses received by staff in this study were of the order of 5% of the limit advised by the National Health and Medical Research Council of Australia (NHMRC) for radiation workers. Nurses received larger doses than radiologists and steps will be taken to reduce this dose further.
Resumo:
Analysis of a major multi-site epidemiologic study of heart disease has required estimation of the pairwise correlation of several measurements across sub-populations. Because the measurements from each sub-population were subject to sampling variability, the Pearson product moment estimator of these correlations produces biased estimates. This paper proposes a model that takes into account within and between sub-population variation, provides algorithms for obtaining maximum likelihood estimates of these correlations and discusses several approaches for obtaining interval estimates. (C) 1997 by John Wiley & Sons, Ltd.