49 resultados para Magnetic resonance imaging


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Semantic priming occurs when a subject is faster in recognising a target word when it is preceded by a related word compared to an unrelated word. The effect is attributed to automatic or controlled processing mechanisms elicited by short or long interstimulus intervals (ISIs) between primes and targets. We employed event-related functional magnetic resonance imaging (fMRI) to investigate blood oxygen level dependent (BOLD) responses associated with automatic semantic priming using an experimental design identical to that used in standard behavioural priming tasks. Prime-target semantic strength was manipulated by using lexical ambiguity primes (e.g., bank) and target words related to dominant or subordinate meaning of the ambiguity. Subjects made speeded lexical decisions (word/nonword) on dominant related, subordinate related, and unrelated word pairs presented randomly with a short ISI. The major finding was a pattern of reduced activity in middle temporal and inferior prefrontal regions for dominant versus unrelated and subordinate versus unrelated comparisons, respectively. These findings are consistent with both a dual process model of semantic priming and recent repetition priming data that suggest that reductions in BOLD responses represent neural priming associated with automatic semantic activation and implicate the left middle temporal cortex and inferior prefrontal cortex in more automatic aspects of semantic processing.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mixture models implemented via the expectation-maximization (EM) algorithm are being increasingly used in a wide range of problems in pattern recognition such as image segmentation. However, the EM algorithm requires considerable computational time in its application to huge data sets such as a three-dimensional magnetic resonance (MR) image of over 10 million voxels. Recently, it was shown that a sparse, incremental version of the EM algorithm could improve its rate of convergence. In this paper, we show how this modified EM algorithm can be speeded up further by adopting a multiresolution kd-tree structure in performing the E-step. The proposed algorithm outperforms some other variants of the EM algorithm for segmenting MR images of the human brain. (C) 2004 Pattern Recognition Society. Published by Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Reasons for performing study: Obtaining magnetic resonance images of the inner hoof wall tissue at the microscopic level would enable early accurate diagnosis of laminitis and therefore more effective therapy. Objectives: To optimise magnetic resonance imaging (MRI) parameters in order to obtain the highest possible resolution of the structures beneath the equine hoof wall. Methods: Magnetic resonance microscopy (MRM) was performed in front feet from 6 cadaver horses using T-2-weighted fast spin echo (FSE-T-2), and T-1-weighted gradient echo (GRE-T-1) sequences. Results: In T-2 weighted FSE images most of the stratum medium showed no signal, however the coronary, terminal and sole papillae were visible. The stratum lamellatum was clearly visible and primary epidermal lamellae could be differentiated from dermal lamellae. Conclusion: Most structures beneath the hoof wall were differentiated. Conventional scanners for diagnostic MRI in horses are low or high field. However this study used ultra-high field scanners currently not available for clinical use. Signal-to-noise ratio (SIN) increases as a function of field strength. An increase of spatial resolution of the image results in a decreased SIN. SIN can also be improved with better coils and the resolution of high field MRI scanners will increase as technology develops and surface array coils become more readily available. Potential relevance: Although MR images with microscopic resolution were obtained ex vivo, this study demonstrates the potential for detection of lamellar pathology as it occurs. Early recognition of the development of laminitis to instigate effective therapy at an earlier stage and may improve the outcome for laminitic horses. Clinical MR is now readily available at 3 T, while 4 T, 7 T and 9 T systems are being used for human whole body applications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Angiography is usually performed as the preoperative road map for those requiring revascularization for lower extremity peripheral arterial disease (PAD). The alternative investigations are ultrasound, 3-D magnetic resonance angiography (3-D MRA) and computed tomography angiography. This pilot study aimed to assess whether 3-D MRA could replace the gold standard angiography in preoperative planning. Eight patients considered for aortoiliac or infrainguinal arterial bypass surgery were recruited. All underwent both imaging modalities within 7 days. A vascular surgeon and a radiologist each reported on the images from both the 3-D MRA and the angiography, with blinding to patient details and each others reports. Comparisons were made between the reports for the angiographic and the 3-D MRA images, and between the reports of the vascular surgeon and the radiologist. Compared to the gold standard angiogram, 3-D MRA had a sensitivity of 77% and specificity of 94% in detecting occlusion, and a sensitivity of 72% and specificity of 90% in differentiating high grade (> 50%) versus low grade (< 50%) stenoses. There was an overall concordance of 78% between the two investigations with a range of 62% in the peroneal artery to 94% in the aorta. 3-D MRA showed flow in 23% of cases where conventional angiography showed no flow. In the present pilot study, 3-D MRA had reasonable concordance with the gold standard angiography, depending on the level of the lesion. At times it showed vessel flow where occlusion was shown on conventional angiogram. 3-D MRA in peripheral vascular disease is challenging the gold standard, but is inconsistent at present.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Magnetic resonance imaging has been used to monitor the diffusion of water at 310 K into a series of semi-IPNs of poly(ethyl methacrylate), PEM, and copolymers of 2-hydroxyethyl methacrylate, HEMA, and tetrahydrofurfuryl methacrylate, THFMA. The diffusion was found to be well described by a Fickian kinetic model in the early stages of the water sorption process, and the diffusion coefficients were found to be slightly smaller than those for the copolymers of HEMA and THFMA, P(HEMA-co-THFMA), containing the same mole fraction of HEMA in the matrix. A second stage sorption process was identified in the later stage of water sorption by the PEM/PTHFMA semi-IPN and for the systems containing a P(HEMA-co-THFMA) component with a mole fraction HEMA of 0.6 or less. This was characterized by the presence of Water near the surface of the cylinders with a longer NMR T-2 relaxation time, which would be characteristic of mobile water, such as water present in large pores or surface fissures. The presence of the drug chlorhexidine in the polymer matrixes at a concentration of 5.625 wt % was found not to modify the properties significantly, but the diffusion coefficients for the water sorption were systematically smaller when the drug was present.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In order to investigate the potential of magic angle spinning nuclear magnetic resonance (MAS NMR) in the elucidation of post-mortem metabolism in muscle biopsies, simultaneous H-1 and (31)p MAS NMR measurements were made continuously on postmortem (20 min to 24 h) muscle longissimus samples from rabbits. The animals had either been or not been given adrenaline (0.5 mg kg(-1) 4 h pre-slaughter) to deplete stores of muscle glycogen. The intracellular pH was calculated from H-1 spectra, and the post-mortem rate of formation of lactate was followed and quantified. Comparison of measurements made on muscle samples from rabbits treated with adrenaline with measurements made on muscle samples from untreated' rabbits revealed significant effects of adrenaline treatment on both pH (pH24 h = 6.42 vs. pH24 It = 5.60) and formation of lactate (16 mmol g(-1) vs. 65 mmol g(-1)). The P-31 NMR spectra were used to follow the rate of degradation of ATP and phosphocreatine. The present study clearly shows that MAS NMR has potential for the study of post-mortem energy metabolism.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The ingress of water into copolymers of 2-hydroxyethyl methacrylate (HEMA) and tetrahydrofurfuryl methacrylate (THFMA) loaded with either one of two model drugs, ie vitamin B-12 or aspirin, was studied at 310 K using three-dimensional nuclear magnetic resonance (3D NMR) imaging. The poly(HEMA) was loaded with 5 wt% of the drugs. From the imaging profiles it was observed that incorporation of vitamin B-12 into the polymers rich in HEMA resulted in crack formation at the interface between the rubbery region and the glassy core on sorption of water, although these cracks were 'healed' behind the diffusion front. However, for the copolymers with low HEMA contents and for those containing aspirin, no evidence for similar crack formation was found. For the copolymers loaded with 5 wt% of aspirin or vitamin B-12 the values of the water diffusion coefficients, determined by curve-fitting the relative water concentration profiles from magnetic resonance imaging (MRI) measurements, were found to be smaller than those obtained from a mass uptake study. (C) 2004 Society of Chemical Industry.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A complex set of axonal guidance mechanisms are utilized by axons to locate and innervate their targets. In the developing mouse forebrain, we previously described several midline glial populations as well as various guidance molecules that regulate the formation of the corpus callosum. Since agenesis of the corpus callosum is associated with over 50 different human congenital syndromes, we wanted to investigate whether these same mechanisms also operate during human callosal development. Here we analyze midline glial and commissural development in human fetal brains ranging from 13 to 20 weeks of gestation using both diffusion tensor magnetic resonance imaging and immunohistochemistry. Through our combined radiological and histological studies, we demonstrate the morphological development of multiple forebrain commissures/decussations, including the corpus callosum, anterior commissure, hippocampal commissure, and the optic chiasm. Histological analyses demonstrated that all the midline glial populations previously described in mouse, as well as structures analogous to the subcallosal sling and cingulate pioneering axons, that mediate callosal axon guidance in mouse, are also present during human brain development. Finally, by Northern blot analysis, we have identified that molecules involved in mouse callosal development, including Slit, Robo, Netrin1, DCC, Nfia, Emx1, and GAP-43, are all expressed in human fetal brain. These data suggest that similar mechanisms and molecules required for midline commissure formation operate during both mouse and human brain development. Thus, the mouse is an excellent model system for studying normal and pathological commissural formation in human brain development. (c) 2006 Wiley-Liss, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Transmural extent of infarction (TME) may be an important determinant of functional recovery and remodeling. Recent animal data suggest that strain rate imaging (SRI) maybe able to identify subendocardial ischemia.We compared SRI and cyclic variation of integrated backscatter (CVIB) for predicting TME in the quantitative assessment of regional subepicardial function. Forty-nine (n = 49) postmyocardial infarct patients (61±10 years, EF 41±10%) underwent tissue Doppler echocardiography (TDE) and contrast enhanced magnetic resonance imaging (CMR). A15 mm×2mm sampling volume (tracked to wall motion) was placed over the long axis subepicardial region of each segment during TDE offline analysis to measure peak longitudinal systolic strain rate (SR), peak longitudinal systolic strain (PS), and CVIB. Findingswere compared with TME classified into two categories of scar thickness by CMR: Non-transmural (TME≤50%), and transmural (TME > 50%). Of 213 segments identified with resting wall motion abnormalities, 145 segments showed delayed hyperenhancement on CMR. SR, PS and CVIB were similar with no significant differences between transmural and non-transmural infarcts regardless of the echo modality.