Resumo:
A single-beam gradient trap could potentially be used to hold a stylus for scanning force microscopy. With a view to development of this technique, we modeled the optical trap as a harmonic oscillator and therefore characterized it by its force constant. We measured force constants and resonant frequencies for 1-4-mu m-diameter polystyrene spheres in a single-beam gradient trap using measurements of back-scattered light. Force constants were determined with both Gaussian and doughnut laser modes, with powers of 3 and 1 mW, respectively. Typical values for spring constants were measured to be between 10(-6) and 4 x 10(-6) N/m. The resonant frequencies of trapped particles were measured to be between 1 and 10 kHz, and the rms amplitudes of oscillations were estimated to be around 40 nm. Our results confirm that the use of the doughnut mode for single-beam trapping is more efficient in the axial direction. (C) 1996 Optical Society of America.
Resumo:
The technique of frequency-resolved optical gating is used to characterize the intensity and the phase of picosecond pulses after propagation through 700 m of fiber at close to the zero-dispersion wavelength. Using the frequency-resolved optical gating technique, we directly measure the severe temporal distortion resulting from the interplay between self-phase modulation and higher-order dispersion in this regime. The measured intensity and phase of the pulses after propagation are found to be in good agreement with the predictions of numerical simulations with the nonlinear Schrodinger equation. (C) 1997 Optical Society of America.
Resumo:
Aims The excretion of phospholipids in urine may be a marker of the early renal toxicity of the aminoglycoside antibiotics. Urinary phospholipids are formed in myeloid bodies which develop in the lysosomes of proximal tubules during treatment with the aminoglycosides, and overflow into the urine. Methods Published assays were modified in order to measure the total phospholipid concentrations in human urine. Phospholipids were extracted from freeze-dried urine samples, digested in concentrated sulphuric acid, and the inorganic phosphorus content determined by complexing with ammonium molybdate and measuring the absorbance at 820 nm. Ten septicaemic patients treated with gentamicin for 5-7 days had significantly higher urine phospholipid concentrations than 10 healthy untreated control subjects (P<0.0001). There was a negative Linear relationship between phospholipid excretion and creatinine clearance (r(2) = 0.71). Results In 34 patients with acute pyelonephritis, increased phospholipid concentrations were observed prior to treatment compared with healthy controls (P<0.001) and did not alter during treatment with gentamicin. However, the phospholipid concentrations decreased significantly after treatment was completed (P<0.03). Conclusions These studies suggest that urinary phospholipids may indicate early aminoglycoside toxicity but with poor specificity, as many of the infections being treated may themselves be associated with phospholipiduria.
Resumo:
The aim of this study was to confirm that the radiation doses received by attendants who manually restrain infants during fluoroscopic procedures are low. Doses to the hands and neck of three radiologists and three nurses performing or assisting at all the fluoroscopic procedures in a children's hospital were measured for 1 month using thermoluminescent dosemeters. All fluoroscopy on children at this hospital is performed without an antiscatter grid. Total doses for the neck ranged from 20 to 50 mu Sv per week and for hands from 40 to 210 mu Sv per week. These doses were shared by the three radiologists and the three nurses. Individual doses received per staff member are very small when compared with the doses received by interventional radiology staff. Doses received by staff in this study were of the order of 5% of the limit advised by the National Health and Medical Research Council of Australia (NHMRC) for radiation workers. Nurses received larger doses than radiologists and steps will be taken to reduce this dose further.
Resumo:
Analysis of a major multi-site epidemiologic study of heart disease has required estimation of the pairwise correlation of several measurements across sub-populations. Because the measurements from each sub-population were subject to sampling variability, the Pearson product moment estimator of these correlations produces biased estimates. This paper proposes a model that takes into account within and between sub-population variation, provides algorithms for obtaining maximum likelihood estimates of these correlations and discusses several approaches for obtaining interval estimates. (C) 1997 by John Wiley & Sons, Ltd.