49 resultados para Finite Volume Methods
Resumo:
Lateral ventricular volumes based on segmented brain MR images can be significantly underestimated if partial volume effects are not considered. This is because a group of voxels in the neighborhood of lateral ventricles is often mis-classified as gray matter voxels due to partial volume effects. This group of voxels is actually a mixture of ventricular cerebro-spinal fluid and the white matter and therefore, a portion of it should be included as part of the lateral ventricular structure. In this note, we describe an automated method for the measurement of lateral ventricular volumes on segmented brain MR images. Image segmentation was carried in combination of intensity correction and thresholding. The method is featured with a procedure for addressing mis-classified voxels in the surrounding of lateral ventricles. A detailed analysis showed that lateral ventricular volumes could be underestimated by 10 to 30% depending upon the size of the lateral ventricular structure, if mis-classified voxels were not included. Validation of the method was done through comparison with the averaged manually traced volumes. Finally, the merit of the method is demonstrated in the evaluation of the rate of lateral ventricular enlargement. (C) 2001 Elsevier Science Inc. All rights reserved.
Resumo:
Numerical modeling of the eddy currents induced in the human body by the pulsed field gradients in MRI presents a difficult computational problem. It requires an efficient and accurate computational method for high spatial resolution analyses with a relatively low input frequency. In this article, a new technique is described which allows the finite difference time domain (FDTD) method to be efficiently applied over a very large frequency range, including low frequencies. This is not the case in conventional FDTD-based methods. A method of implementing streamline gradients in FDTD is presented, as well as comparative analyses which show that the correct source injection in the FDTD simulation plays a crucial rule in obtaining accurate solutions. In particular, making use of the derivative of the input source waveform is shown to provide distinct benefits in accuracy over direct source injection. In the method, no alterations to the properties of either the source or the transmission media are required. The method is essentially frequency independent and the source injection method has been verified against examples with analytical solutions. Results are presented showing the spatial distribution of gradient-induced electric fields and eddy currents in a complete body model.
Resumo:
A high definition, finite difference time domain (HD-FDTD) method is presented in this paper. This new method allows the FDTD method to be efficiently applied over a very large frequency range including low frequencies, which are problematic for conventional FDTD methods. In the method, no alterations to the properties of either the source or the transmission media are required. The method is essentially frequency independent and has been verified against analytical solutions within the frequency range 50 Hz-1 GHz. As an example of the lower frequency range, the method has been applied to the problem of induced eddy currents in the human body resulting from the pulsed magnetic field gradients of an MRI system. The new method only requires approximately 0.3% of the source period to obtain an accurate solution. (C) 2003 Elsevier Science Inc. All rights reserved.
Resumo:
In modern magnetic resonance imaging (MRI), patients are exposed to strong, nonuniform static magnetic fields outside the central imaging region, in which the movement of the body may be able to induce electric currents in tissues which could be possibly harmful. This paper presents theoretical investigations into the spatial distribution of induced electric fields and currents in the patient when moving into the MRI scanner and also for head motion at various positions in the magnet. The numerical calculations are based on an efficient, quasi-static, finite-difference scheme and an anatomically realistic, full-body, male model. 3D field profiles from an actively shielded 4T magnet system are used and the body model projected through the field profile with a range of velocities. The simulation shows that it possible to induce electric fields/currents near the level of physiological significance under some circumstances and provides insight into the spatial characteristics of the induced fields. The results are extrapolated to very high field strengths and tabulated data shows the expected induced currents and fields with both movement velocity and field strength. (C) 2003 Elsevier Science (USA). All rights reserved.
Resumo:
Background. Australian Aborigines are experiencing epidemic proportions of renal disease, marked by albuminuria and, variably, hematuria. They also have high rates of low birth weight, which have been associated with lower kidney volumes and higher blood pressures. The authors evaluated relationships between kidney volume, blood pressure, albuminuria, and hematuria in 1 homogeneous group. Methods Forty-three percent (672 of 1,560) of the population in a remote coastal Australian Aboriginal community aged 4.4 to 72.1 years participated in the study. Results: Kidney size correlated closely with body size. Systolic blood pressure (SBP) was correlated inversely with kidney length and kidney volume, after adjusting for age, sex, and body surface area (BSA); a 1-cm increase in mean kidney length was associated with a 2.2-mm Hg decrease in SBP, and a 10-mL increase in mean kidney volume was associated with a 0.6-mm Hg decrease in SBP (P = 0.001). Mean kidney volume explained 10% of the variance in SBP in a multivariate model containing age, sex, and BSA. In addition to higher SBP, adults who had the lowest quartiles of kidney volume also had the highest levels of overt albuminuria (P = 0.044). Conclusion: Smaller kidneys predispose to higher blood pressures and albuminuria in this population. The lower volumes possibly represent kidneys with reduced nephron numbers, which might be related to an adverse intrauterine environment. Susceptibility to renal disease could be a direct consequence of reduced nephron numbers; the higher blood pressures with which they are associated could also contribute to, as well as derive from, this association.
Resumo:
Background The degree of volume depletion in severe malaria is currently unknown, although knowledge of fluid compartment volumes can guide therapy. To assist management of severely ill children, and to test the hypothesis that volume changes in fluid compartments reflect disease severity, we measured body compartment volumes in Gabonese children with malaria. Methods and Findings Total body water volume (TBW) and extracellular water volume (ECW) were estimated in children with severe or moderate malaria and in convalescence by tracer dilution with heavy water and bromide, respectively. Intracellular water volume (ICW) was derived from these parameters. Bioelectrical impedance analysis estimates of TBW and ECW were calibrated and bioelectrical impedance analysis measurements were taken daily against dilution methods, until discharge. Sixteen children had severe and 19 moderate malaria. Severe childhood malaria was associated with depletion of TBW (mean [SD] of 37 [33] ml/kg, or 6.7% [6.0%]) relative to measurement at discharge. This is defined as mild dehydration in other conditions. ECW measurements were normal on admission in children with severe malaria and did not rise in the first few days of admission. Volumes in different compartments (TBW, ECW, and ICW) were not related to hyperlactataemia or other clinical and laboratory markers of disease severity. Moderate malaria was not associated with a depletion of TBW. Conclusions Significant hypovolaemia does not exacerbate complications of severe or moderate malaria. As rapid rehydration of children with malaria may have risks, we suggest that fluid replacement regimens should aim to correct fluid losses over 12-24 h.
Resumo:
This paper discusses efficient simulation methods for stochastic chemical kinetics. Based on the tau-leap and midpoint tau-leap methods of Gillespie [D. T. Gillespie, J. Chem. Phys. 115, 1716 (2001)], binomial random variables are used in these leap methods rather than Poisson random variables. The motivation for this approach is to improve the efficiency of the Poisson leap methods by using larger stepsizes. Unlike Poisson random variables whose range of sample values is from zero to infinity, binomial random variables have a finite range of sample values. This probabilistic property has been used to restrict possible reaction numbers and to avoid negative molecular numbers in stochastic simulations when larger stepsize is used. In this approach a binomial random variable is defined for a single reaction channel in order to keep the reaction number of this channel below the numbers of molecules that undergo this reaction channel. A sampling technique is also designed for the total reaction number of a reactant species that undergoes two or more reaction channels. Samples for the total reaction number are not greater than the molecular number of this species. In addition, probability properties of the binomial random variables provide stepsize conditions for restricting reaction numbers in a chosen time interval. These stepsize conditions are important properties of robust leap control strategies. Numerical results indicate that the proposed binomial leap methods can be applied to a wide range of chemical reaction systems with very good accuracy and significant improvement on efficiency over existing approaches. (C) 2004 American Institute of Physics.
Resumo:
We introduce a new class of quantum Monte Carlo methods, based on a Gaussian quantum operator representation of fermionic states. The methods enable first-principles dynamical or equilibrium calculations in many-body Fermi systems, and, combined with the existing Gaussian representation for bosons, provide a unified method of simulating Bose-Fermi systems. As an application relevant to the Fermi sign problem, we calculate finite-temperature properties of the two dimensional Hubbard model and the dynamics in a simple model of coherent molecular dissociation.
Resumo:
Background: Qualitative interpretation of myocardial contrast echocardiography (MCE) improves the accuracy of wall-motion analysis for assessment of coronary artery disease (CAD). We examined the feasibility and accuracy of quantitative MCE for diagnosis of CAD. Methods: Dipyridamole/exercise stress MCE (destruction-replenishment protocol with real-time imaging) was performed in 90 patients undergoing quantitative coronary angiography, 48 of whom had significant (> 50%) stenoses. MCE was repeated with exercise alone in 18 patients. Myocardial blood flow (A*beta) was obtained from blood volume (A) and time to refill (beta). Results: Quantification of flow reserve was feasible in 88%. The mean A*beta reserve in the anterior wall was significantly impaired for patients with left anterior descending coronary artery disease (n = 28) compared with those with no disease (1.6 +/- 1.2 vs; 4.0 +/- 2.5, P <=.001). This reflected impaired beta reserve, with no difference in the A reserve. Applying a receiver operating characteristic curve derived cutoff of 2.0 for A*beta reserve, quantitative MCE was 76% sensitive and 71% specific for the diagnosis of significant left anterior descending coronary artery stenosis. Posterior circulation results were similar, with 78% sensitivity and 59% specificity for detection of posterior CAD. Overall, quantitative MCE was similarly sensitive to qualitative approach for diagnosis of CAD (88% vs 93%), but with lower specificity (52% vs 65%, P =.07). In 18 patients restudied with pure exercise stress, the mean myocardial blood flow reserve was less than after combined stress (2.1 +/- 1.6 vs 3.7 +/- 1.9, P =.01). Conclusion: Quantitative MCE is feasible for the diagnosis of CAD with dipyridamole/exercise stress. Dipyridamole prolongs postexercise hyperemia, augmenting the degree of hyperemia at the time of imaging.
Resumo:
Objectives: Left atrial (LA) volume (LAV) is a prognostically important biomarker for diastolic dysfunction, but its reproducibility on repeated testing is not well defined. LA assessment with 3-dimensional. (3D) echocardiography (3DE) has been validated against magnetic resonance imaging, and we sought to assess whether this was superior to existing measurements for sequential echocardiographic follow-up. Methods: Patients (n = 100; 81 men; age 56 +/- 14 years) presenting for LA evaluation were studied with M-mode (MM) echocardiography, 2-dimensional (2D) echocardiography, and 3DE. Test-retest variation was performed by a complete restudy by a separate sonographer within 1 hour without alteration of hemodynamics or therapy. In all, 20 patients were studied for interobserver and intraobserver variation. LAVs were calculated by using M-mode diameter and planimetered atrial area in the apical. 4-chamber view to calculate an assumed sphere, as were prolate ellipsoid, Simpson's biplane, and biplane area-length methods. All were compared with 3DE. Results: The average LAV was 72 +/- 27 mL by 3DE. There was significant underestimation of LAV by M-mode (35 +/- 20 mL, r = 0.66, P < .01). The 3DE and various 2D echocardiographic techniques were well correlated: LA planimetry (85 +/- 38 mL, r = 0.77, P < .01), prolate ellipsoid (73 +/- 36 mL, r = 0.73, P = .04), area-length (64 +/- 30 mL, r = 0.74, P < .01), and Simpson's biplane (69 +/- 31 mL, r = 0.78, P = .06). Test-retest variation for 3DE was most favorable (r = 0.98, P < .01), with the prolate ellipsoid method showing most variation. Interobserver agreement between measurements was best for 3DE (r = 0.99, P < .01), with M-mode the worst (r = 0.89, P < .01). Intraobserver results were similar to interobserver, the best correlation for 3DE (r = 0.99, P < .01), with LA planimetry the worst (r = 0.91, P < .01). Conclusions. The 2D measurements correlate closely with 3DE. Follow-up assessment in daily practice appears feasible and reliable with both 2D and 3D approaches.
Resumo:
What is the computational power of a quantum computer? We show that determining the output of a quantum computation is equivalent to counting the number of solutions to an easily computed set of polynomials defined over the finite field Z(2). This connection allows simple proofs to be given for two known relationships between quantum and classical complexity classes, namely BQP subset of P-#P and BQP subset of PP.
Resumo:
This paper presents a finite-difference time-domain (FDTD) simulator for electromagnetic analysis and design applications in MRI. It is intended to be a complete FDTD model of an MRI system including all RF and low-frequency field generating units and electrical models of the patient. The pro-ram has been constructed in an object-oriented framework. The design procedure is detailed and the numerical solver has been verified against analytical solutions for simple cases and also applied to various field calculation problems. In particular, the simulator is demonstrated for inverse RF coil design, optimized source profile generation, and parallel imaging in high-frequency situations. The examples show new developments enabled by the simulator and demonstrate that the proposed FDTD framework can be used to analyze large-scale computational electromagnetic problems in modern MRI engineering. (C) 2004 Elsevier Inc. All rights reserved.
Resumo:
In this paper, numerical simulations are used in an attempt to find optimal Source profiles for high frequency radiofrequency (RF) volume coils. Biologically loaded, shielded/unshielded circular and elliptical birdcage coils operating at 170 MHz, 300 MHz and 470 MHz are modelled using the FDTD method for both 2D and 3D cases. Taking advantage of the fact that some aspects of the electromagnetic system are linear, two approaches have been proposed for the determination of the drives for individual elements in the RF resonator. The first method is an iterative optimization technique with a kernel for the evaluation of RF fields inside an imaging plane of a human head model using pre-characterized sensitivity profiles of the individual rungs of a resonator; the second method is a regularization-based technique. In the second approach, a sensitivity matrix is explicitly constructed and a regularization procedure is employed to solve the ill-posed problem. Test simulations show that both methods can improve the B-1-field homogeneity in both focused and non-focused scenarios. While the regularization-based method is more efficient, the first optimization method is more flexible as it can take into account other issues such as controlling SAR or reshaping the resonator structures. It is hoped that these schemes and their extensions will be useful for the determination of multi-element RF drives in a variety of applications.
Resumo:
In a recent study, severe distortions in the proton images of an excised, fixed, human brain in an 11.1 Tesla/40 cm MR instrument have been observed, and the effect modeled on phantom images using a finite difference time domain (FDTD) model. in the present study, we extend these simulations to that of a complete human head, employing a hybrid FDTD and method of moments (MoM) approach, which provides a validated method for simulating biological samples in coil structures. The effect of fixative on the image distortions is explored. importantly, temperature distributions within the head are also simulated using a bioheat method based on parameters derived from the electromagnetic simulations. The MoM/FDTD simulations confirm that the transverse magnetic field (B,) from a ReCav resonator exhibits good homogeneity in air but strong inhomogeneity when loaded with the head with or without fixative. The fixative serves to increase the distortions, but they are still significant for the in vivo simulations. The simulated signal intensity (SI) distribution within the sample confirm the distortions in the experimental images are caused by the complex interactions of the incident electromagnetic fields with tissue, which is heterogeneous in terms of conductivity and permittivity. The temperature distribution is likewise heterogeneous, raising concerns regarding hot spot generation in the sample that may exceed acceptable levels in future in vivo studies. As human imaging at 11.1 T is some time away, simulations are important in terms of predicting potential safety issues as well as evaluating practical concerns about the quality of images. Simulation on a whole human head at 11.1 T implies the wave behavior presents significant engineering challenges for ultra-high-field (UHF) MRI. Novel strategies will have to be employed in imaging technique and resonator design for UHF MRI to achieve the theoretical signal-to-noise ratio (SNR) improvements it offers over lower field systems. (C) 2005 Wiley Periodicals, Inc.
Resumo:
Background and Purpose. Arm lymphedema following breast cancer In this study, we assessed the surgery is a continuing problem. reliability and validity of circumferential measurements and water displacement for measuring upper-limb volume. Subjects. Participants included subjects who had had breast cancer surgery, including axillary dissection-19 with and 22 without a diagnosis of arm lymphedema-and 25 control subjects. Methods. Two raters measured each subject by using circumferential tape measurements at specified distances from the fingertips and in relation to anatornic landmarks and by using water displacement. Interrater reliability was calculated by analysis of variance and multilevel modeling. Volumes from circumferential measurements were compared with those from water displacement by use of means and correlation coefficients, respectively. The standard error of measurement, minimum detectable change (MDC), and limits of agreement (LOA) for volumes also were calculated. Results. Arm volumes obtained with these methods had high reliability. Compared with volumes from water displacement, volumes from circumferential measurements had high validity, although these volumes were slightly larger. Expected differences between subjects with and without clinical lymphedema following breast cancer were found. The MDC of volumes or the error associated with a single measure for data based oil anatomic landmarks was lower than that based oil distance from fingertips. The mean LOA with water displacement were lower for data based on anatomic landmarks than for data based on distance from fingertips. Discussion and Conclusion. Volumes calculated from anatomic landmarks are reliable, valid, and more accurate than those obtained from circumferential measurements based on distance from fingertips.