61 resultados para Double Layer Capacitance
Resumo:
The problem of the negative values of the interaction parameter in the equation of Frumkin has been analyzed with respect to the adsorption of nonionic molecules on energetically homogeneous surface. For this purpose, the adsorption states of a homologue series of ethoxylated nonionic surfactants on air/water interface have been determined using four different models and literature data (surface tension isotherms). The results obtained with the Frumkin adsorption isotherm imply repulsion between the adsorbed species (corresponding to negative values of the interaction parameter), while the classical lattice theory for energetically homogeneous surface (e.g., water/air) admits attraction alone. It appears that this serious contradiction can be overcome by assuming heterogeneity in the adsorption layer, that is, effects of partial condensation (formation of aggregates) on the surface. Such a phenomenon is suggested in the Fainerman-Lucassen-Reynders-Miller (FLM) 'Aggregation model'. Despite the limitations of the latter model (e.g., monodispersity of the aggregates), we have been able to estimate the sign and the order of magnitude of Frumkin's interaction parameter and the range of the aggregation numbers of the surface species. (C) 2004 Elsevier B.V All rights reserved.
Resumo:
We conduct a theoretical analysis to investigate the double diffusion-driven convective instability of three-dimensional fluid-saturated geological fault zones when they are heated uniformly from below. The fault zone is assumed to be more permeable than its surrounding rocks. In particular, we have derived exact analytical solutions to the total critical Rayleigh numbers of the double diffusion-driven convective flow. Using the corresponding total critical Rayleigh numbers, the double diffusion-driven convective instability of a fluid-saturated three-dimensional geological fault zone system has been investigated. The related theoretical analysis demonstrates that: (1) The relative higher concentration of the chemical species at the top of the three-dimensional geological fault zone system can destabilize the convective flow of the system, while the relative lower concentration of the chemical species at the top of the three-dimensional geological fault zone system can stabilize the convective flow of the system. (2) The double diffusion-driven convective flow modes of the three-dimensional geological fault zone system are very close each other and therefore, the system may have the similar chance to pick up different double diffusion-driven convective flow modes, especially in the case of the fault thickness to height ratio approaching 0. (3) The significant influence of the chemical species diffusion on the convective instability of the three-dimensional geological fault zone system implies that the seawater intrusion into the surface of the Earth is a potential mechanism to trigger the convective flow in the shallow three-dimensional geological fault zone system.
Resumo:
Numerical methods are used to simulate the double-diffusion driven convective pore-fluid flow and rock alteration in three-dimensional fluid-saturated geological fault zones. The double diffusion is caused by a combination of both the positive upward temperature gradient and the positive downward salinity concentration gradient within a three-dimensional fluid-saturated geological fault zone, which is assumed to be more permeable than its surrounding rocks. In order to ensure the physical meaningfulness of the obtained numerical solutions, the numerical method used in this study is validated by a benchmark problem, for which the analytical solution to the critical Rayleigh number of the system is available. The theoretical value of the critical Rayleigh number of a three-dimensional fluid-saturated geological fault zone system can be used to judge whether or not the double-diffusion driven convective pore-fluid flow can take place within the system. After the possibility of triggering the double-diffusion driven convective pore-fluid flow is theoretically validated for the numerical model of a three-dimensional fluid-saturated geological fault zone system, the corresponding numerical solutions for the convective flow and temperature are directly coupled with a geochemical system. Through the numerical simulation of the coupled system between the convective fluid flow, heat transfer, mass transport and chemical reactions, we have investigated the effect of the double-diffusion driven convective pore-fluid flow on the rock alteration, which is the direct consequence of mineral redistribution due to its dissolution, transportation and precipitation, within the three-dimensional fluid-saturated geological fault zone system. (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
We consider the quantum dynamics of a neutral atom Bose-Einstein condensate in a double-well potential, including many-body hard-sphere interactions. Using a mean-field factorization we show that the coherent oscillations due to tunneling are suppressed when the number of atoms exceeds a critical value. An exact quantum solution, in a two-mode approximation, shows that the mean-field solution is modulated by a quantum collapse and revival sequence.
Resumo:
We introduce the super-Yangian double DY(h over bar), [gl(m/n)] and its central extension DY(h over bar)[gl(m/n)]. We give their defining relations in terms of current generators and obtain Drinfeld co-multiplication. (C) 1997 Elsevier Science B.V.
Resumo:
Some beta (1)- and beta (2)-adrenoceptor-blocking agents, such as (-)-CGP 12177, cause cardiostimulant effects at concentrations considerably higher than those that antagonise the effects of catecholamines. The cardiostimulant effects of these non-conventional partial agonists are relatively resistant to blockade by (-)-propranolol and have been proposed to be mediated through putative beta (4)-adrenoceptors or through atypical states of either beta (1)- or beta (2)-adrenoceptors. We investigated the effects of (-)-CGP 12177 on sinoatrial rate and left atrial contractile force as well as the ventricular binding of (-)-[H-3]CGP 12177 in tissues from wild-type, beta (2)-adrenoceptor knockout and beta (1)/beta (2)-adrenoceptor double knockout mice. The cardiostimulant effects of (-)-CGP 12177 were present in wildtype and beta (2)-adrenoceptor knockout mice but were absent in beta (1)/beta (2)-adrenoceptor double knockout mice. Thus, the presence of beta (1)-adrenoceptors is obligatory for the cardiostimulant effects of (-)-CGP 12177. It appears therefore that an atypical state of the beta (1)-adrenoceptor contributes to the mediation of the cardiostimulant effects induced by non-conventional partial agonists. Ventricular beta (1)- and beta (2)-adrenoceptors, labelled in wild-type with a K(D)similar to0.5 nmol/l (similar to 16 fmol/mg protein), were absent in beta (1)/beta (2)-adrenoceptor double knockout mice. However, a high density binding site (similar to 154-391 fmol/mg protein) that did not saturate completely (K(D)similar to 80-200 nM) was labelled by (-)-[H-3]CGP 12177 in the three groups of mice, being distinct from beta (1)- and beta (2)-adrenoceptors, as well as from the site mediating the agonist effects of(-)-CGP 12177.
Resumo:
The use of gate-to-drain capacitance (C-gd) measurement as a tool to characterize hot-carrier-induced charge centers in submicron n- and p-MOSFET's has been reviewed and demonstrated. By analyzing the change in C-gd measured at room and cryogenic temperature before and after high gate-to-drain transverse field (high field) and maximum substrate current (I-bmax) stress, it is concluded that the degradation was found to be mostly due to trapping of majority carriers and generation of interface states. These interface states were found to be acceptor states at top half of band gap for n-MOSFETs and donor states at bottom half of band gap for p-MOSFETs. In general, hot electrons are more likely to be trapped in gate oxide as compared to hot holes while the presence of hot holes generates more interface states. Also, we have demonstrated a new method for extracting the spatial distribution of oxide trapped charge, Q(ot), through gate-to-substrate capacitance (C-gb) measurement. This method is simple to implement and does not require additional information from simulation or detailed knowledge of the device's structure. (C) 2001 Elsevier Science Ltd. All rights reserved.
Resumo:
A new method to extract MOSFET's threshold voltage VT by measurement of the gate-to-substrate capacitance C-gb of the transistor is presented. Unlike existing extraction methods based on I-V data, the measurement of C-gb does not require de drain current to now between drain and source thus eliminating the effects of source and drain series resistance R-S/D, and at the same time, retains a symmetrical potential profile across the channel. Experimental and simulation results on devices with different sizes are presented to justify the proposed method.
Resumo:
Background: Codeine is frequently added to paracetamol to treat post-operative dento-alveolar pain; studies have shown effectiveness in relief of post-operative pain at high doses but at the expense of central nervous and gastrointestinal side effects. There has been no trial to compare the efficacy and safety of paracetamol 1000mg with paracetamol 1000mg combined with codeine 30mg. Method. A randomized, single centre, double-blind prospective parallel group trial was performed to compare paracetamol 1000mg with paracetamol 1000mg with codeine 30mg for the relief of pain following surgical removal of impacted third molars, and analysed on an intention-to-treat (ITT) basis. Eighty-two patients were assigned randomly to receive either drug for a maximum of three doses. Patients recorded their pain intensity one hour after surgery and hourly thereafter for 12 hours. Results: The average increase in pain intensity over 12 hours was significantly less in patients receiving paracetamol plus codeine than in those receiving paracetamol alone (p=0.03) -1.81cm/h compared with 0.45cm/h - a difference of 1.13cm/h (95 per cent Cl: 0.18 to 2.08). Of the patients who received the paracetamol codeine combination, 62 per cent used escape medication compared with 75 per cent of those on paracetamol alone (p=0.20). There was no significant difference between the two groups in the proportion of patients experiencing adverse events (P=0.5). Conclusion: A combination of 1000mg paracetamol and 30mg codeine was significantly more effective in controlling pain for 12 hours following third molar removal, with no significant difference of side effects during the 12 hour period studied.