26 resultados para weighted finite difference approximation scheme
Resumo:
Rotating disk voltammetry is routinely used to study electrochemically driven enzyme catalysis because of the assumption that the method produces a steady-state system. This assumption is based on the sigmoidal shape of the voltammograms. We have introduced an electrochemical adaptation of the King-Altman method to simulate voltammograms in which the enzyme catalysis, within an immobilized enzyme layer, is steadystate. This method is readily adaptable to any mechanism and provides a readily programmable means of obtaining closed form analytical equations for a steady-state system. The steady-state simulations are compared to fully implicit finite difference (FIFD) simulations carried out without any steady-state assumptions. On the basis of our simulations, we conclude that, under typical experimental conditions, steady-state enzyme catalysis is unlikely to occur within electrode-immobilized enzyme layers and that typically sigmoidal rotating disk voltammograms merely reflect a mass transfer steady state as opposed to a true steady state of enzyme intermediates at each potential.
Resumo:
An inverse methodology for the design of biologically loaded radio-frequency (RF) coils for magnetic resonance imaging applications is described. Free space time-harmonic electromagnetic Green's functions and de-emphasized B-1 target fields are used to calculate the current density on the coil cylinder. In theory, with the B-1 field de-emphasized in the middle of the RF transverse plane, the calculated current distribution can generate an internal magnetic field that can reduce the central overemphasis effect caused by field/tissue interactions at high frequencies. The current distribution of a head coil operating at 4 T (170 MHz) is calculated using an inverse methodology with de-emphasized B-1. target fields. An in-house finite-difference time-domain routine is employed to evaluate B-1 field and signal intensity inside a homogenous cylindrical phantom and then a complete human head model. A comparison with a conventional RF birdcage coil is carried out and demonstrates that this method can help in decreasing the normal bright region caused by field/tissue interactions in head images at 170 MHz and higher field strengths.
Resumo:
A new transceive system for chest imaging for MRI applications is presented. A focused, eight-element transceive torso phased array coil is designed to investigate transmitting a focused radiofrequency field deep within the torso and to enhance signal homogeneity in the heart region. The system is used in conjunction with the SENSE reconstruction technique to enable focused parallel imaging. A hybrid finite-difference-time-domain/method-of-moments method is used to accurately predict the radiofrequency behavior inside the human torso. The simulation results reported herein demonstrate the feasibility of the design concept, which shows that radiofrequency field focusing with SENSE reconstruction is theoretically achievable. (c) 2005 Wiley-Liss, Inc.
Resumo:
In a recent study, severe distortions in the proton images of an excised, fixed, human brain in an 11.1 Tesla/40 cm MR instrument have been observed, and the effect modeled on phantom images using a finite difference time domain (FDTD) model. in the present study, we extend these simulations to that of a complete human head, employing a hybrid FDTD and method of moments (MoM) approach, which provides a validated method for simulating biological samples in coil structures. The effect of fixative on the image distortions is explored. importantly, temperature distributions within the head are also simulated using a bioheat method based on parameters derived from the electromagnetic simulations. The MoM/FDTD simulations confirm that the transverse magnetic field (B,) from a ReCav resonator exhibits good homogeneity in air but strong inhomogeneity when loaded with the head with or without fixative. The fixative serves to increase the distortions, but they are still significant for the in vivo simulations. The simulated signal intensity (SI) distribution within the sample confirm the distortions in the experimental images are caused by the complex interactions of the incident electromagnetic fields with tissue, which is heterogeneous in terms of conductivity and permittivity. The temperature distribution is likewise heterogeneous, raising concerns regarding hot spot generation in the sample that may exceed acceptable levels in future in vivo studies. As human imaging at 11.1 T is some time away, simulations are important in terms of predicting potential safety issues as well as evaluating practical concerns about the quality of images. Simulation on a whole human head at 11.1 T implies the wave behavior presents significant engineering challenges for ultra-high-field (UHF) MRI. Novel strategies will have to be employed in imaging technique and resonator design for UHF MRI to achieve the theoretical signal-to-noise ratio (SNR) improvements it offers over lower field systems. (C) 2005 Wiley Periodicals, Inc.
Resumo:
A new method for ameliorating high-field image distortion caused by radio frequency/tissue interaction is presented and modeled, The proposed method uses, but is not restricted to, a shielded four-element transceive phased array coil and involves performing two separate scans of the same slice with each scan using different excitations during transmission. By optimizing the amplitudes and phases for each scan, antipodal signal profiles can be obtained, and by combining both images together, the image distortion can be reduced several-fold. A hybrid finite-difference time-domain/method-of-moments method is used to theoretically demonstrate the method and also to predict the radio frequency behavior inside the human head. in addition, the proposed method is used in conjunction with the GRAPPA reconstruction technique to enable rapid imaging. Simulation results reported herein for IIT (470 MHz) brain imaging applications demonstrate the feasibility of the concept where multiple acquisitions using parallel imaging elements with GRAPPA reconstruction results in improved image quality. (c) 2006 Wiley Periodicals, Inc.
Resumo:
Due to complex field/tissue interactions, high-field magnetic resonance (MR) images suffer significant image distortions that result in compromised diagnostic quality. A new method that attempts to remove these distortions is proposed in this paper and is based on the use of transceiver-phased arrays. The proposed system uses, in the examples presented herein, a shielded four-element transceive-phased array head coil and involves performing two separate scans of the same slice with each scan using different excitations during transmission. By optimizing the amplitudes and phases for each scan, antipodal signal profiles can be obtained, and by combining both the images together, the image distortion can be reduced several fold. A combined hybrid method of moments (MoM)/finite element method (FEM) and finite-difference time-domain (FDTD) technique is proposed and used to elucidate the concept of the new method and to accurately evaluate the electromagnetic field (EMF) in a human head model. In addition, the proposed method is used in conjunction with the generalized auto-calibrating partially parallel acquisitions (GRAPPA) reconstruction technique to enable rapid imaging of the two scans. Simulation results reported herein for 11-T (470-MHz) brain imaging applications show that the new method with GRAPPA reconstruction theoretically results in improved image quality and that the proposed combined hybrid MoM/FEM and FDTD technique is. suitable for high-field magnetic resonance imaging (MRI) numerical analysis.
Resumo:
Aim of study: As part of a Cochrane review of viscosupplementation in knee OA, randomised controlled trials (RCT) were reviewed to evaluate evidence for the efficacy of viscosupplementation with Hylan G-F 20 compared to placebo. Methods: Electronic searches were conducted of MEDLINE, EMBASE, Premedline, Current Contents, and CENTRAL. Human, RCT involving Hylan G-F 20 compared to placebo, published prior to 1Q2004, were included. Trials were selected and data extracted by two independent reviewers. Methodological quality was assessed with the Jadad criteria by two reviewers. Data on the OARSI and OMERACT core set clinical outcome measures were extracted where possible. Weighted mean difference (WMD), based on post-test scores, and 95% confidence intervals (CI) were calculated for continuous outcome measures and relative risk (RR) for dichotomous outcome measures. Results: Seven RCT met the inclusion criteria. Median methodological quality was 4 (range 1–5). A further two studies were only reported in abstract form (Jadad score Z 1) and contained insufficient extractable data for inclusion in the analysis. Nine RCT, which compared Hylan G-F 20 to other interventions such as intra-articular corticosteroid, physiotherapy, NSAID, appropriate care, intra-articular gaseous oxygen and other hyaluronan, are not reported here. Twenty-three studies failed to meet inclusion criteria and were excluded. Hylan G-F 20 was more efficacious than placebo at 1–4 weeks post-injection for pain on weight-bearing WMD (random effects [RE]) 13 mm on a 0–100 mm VAS (P Z 0.002) based on 6 RCT. This difference was even greater at 5–13 weeks post-injection, 22 m (RE) (P Z 0.001) based on 5 RCT, and at 14–6 weeks postinjection, 21 m (RE) (P Z 0.006) based on 4 RCT. Hylan G-F 20 was more efficacious than placebo at 1–4 weeks post-injection for pain at night, WMD 7 mm on a 0–100 mm VAS (P Z 0.003) based on 5 RCT. This difference was even greater at 5–13 weeks post-injection, 11 mm (P Z 0.008) based on 4 RCT, and at 14–26 weeks post-injection, 17 mm (P ! 0.00001) based on 3 RCT. There was no significant difference (WMD 8 mm) between Hylan G-F 20 C oral placebo and arthrocentesis C oral placebo at 5–13 weeks post-injection for WOMAC Pain, but Hylan G-F 20 C oral placebo was more efficacious than arthrocentesis C oral placebo for WOMAC Function, WMD 9 mm on a 0–100 mm VAS (P Z 0.01) (Dickson, 2001). Hylan G-F 20 was more effective than placebo at 1–4 weeks postinjection for the variable designed treatment efficacy, WMD 22 mm on a 0–100 mm VAS (P ! 0.00001) based on improvement in 4 RCT. This difference was even greater at 5–13 weeks post injection, 35 mm (P ! 0.00001). Conclusions: Evidence from this updated Cochrane review supports the superior efficacy of Hylan G-F 20 compared to placebo on weight-bearing pain, night pain, function and treatment efficacy in the treatment of knee OA.
Resumo:
A stochastic model for solute transport in aquifers is studied based on the concepts of stochastic velocity and stochastic diffusivity. By applying finite difference techniques to the spatial variables of the stochastic governing equation, a system of stiff stochastic ordinary differential equations is obtained. Both the semi-implicit Euler method and the balanced implicit method are used for solving this stochastic system. Based on the Karhunen-Loeve expansion, stochastic processes in time and space are calculated by means of a spatial correlation matrix. Four types of spatial correlation matrices are presented based on the hydraulic properties of physical parameters. Simulations with two types of correlation matrices are presented.
Resumo:
An object-oriented finite-difference time-domain (FDTD) simulator has been developed for electromagnetic study and design applications in Magnetic Resonance Imaging. It is aimed to be a complete FDTD model of an MRI system including all high and low-frequency field generating units and electrical models of the patient. The design method is described and MRI-based numerical examples are presented to illustrate the function of the numerical solver, particular emphasis is placed on high field studies.
Resumo:
The ability to grow microscopic spherical birefringent crystals of vaterite, a calcium carbonate mineral, has allowed the development of an optical microrheometer based on optical tweezers. However, since these crystals are birefringent, and worse, are expected to have non-uniform birefringence, computational modeling of the microrheometer is a highly challenging task. Modeling the microrheometer - and optical tweezers in general - typically requires large numbers of repeated calculations for the same trapped particle. This places strong demands on the efficiency of computational methods used. While our usual method of choice for computational modelling of optical tweezers - the T-matrix method - meets this requirement of efficiency, it is restricted to homogeneous isotropic particles. General methods that can model complex structures such as the vaterite particles, such as finite-difference time-domain (FDTD) or finite-difference frequency-domain (FDFD) methods, are inefficient. Therefore, we have developed a hybrid FDFD/T-matrix method that combines the generality of volume-discretisation methods such as FDFD with the efficiency of the T-matrix method. We have used this hybrid method to calculate optical forces and torques on model vaterite spheres in optical traps. We present and compare the results of computational modelling and experimental measurements.
Resumo:
A finite difference time domain (FDTD) method is applied to investigate capabilities of an ultra-wide band (UWB) radar system to detect a breast tumor. The first part of the investigations concerns FDTD simulations of a phantom formed by a plastic container with liquid and a small reflecting target. The second part focuses on a three-dimensional numerical breast model with a small tumor. FDTD simulations are carried out assuming a planar incident wave. Various time snap shots of the electromagnetic field are recorded to learn about the physical phenomenon of reflection and scattering in different layers of the phantom.