72 resultados para plasma concentration


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: The relationship between six descriptors of lactate increase, peak (V) over dot O-2,W-peak, and 1-h cycling performance were compared in 24 trained, female cyclists (peak (V) over dot O-2 = 48.11 +/- 6.32 mL . kg(-1) . min(-1)). Methods: The six descriptors of lactate increase were: 1) lactate threshold (LT; the power output at which plasma lactate concentration begins to increase above the resting level during an incremental exercise test), 2) LT1 (the power output at which plasma lactate increases by 1 mM or more), 3) LTD (the lactate threshold calculated by the D-max method), 4) LTMOD (the lactate threshold calculated by a modified D-max method), 5) L4 (the power output at which plasma lactate reaches a concentration of 4 mmol-L-1), and 6) LTLOG (the power output at which plasma lactate concentration begins to increase when the log([La-]) is plotted against the log (power output)). Subjects first completed a peak (V) over dot O-2 test on a cycle ergometer. Finger-tip capillary blood was sampled within 30 s of the end of each 3-min stage for analysis of plasma lactate. Endurance performance was assessed 7 d later using a 1-h cycle test (OHT) in which subjects were directed to achieve the highest possible average power output. Results: The mean power output (W) for the OHT (+/- SD) was 183.01 +/- 18.88, and for each lactate variable was: LT (138.54 +/- 46.61), LT1 (179.17 +/- 27.25), LTLOG (143.97 +/- 45.74), L4 (198.09 +/- 33.84), LTD (178.79 +/- 24.07), LTMOD (212.28 +/- 31.75). Average power output during the OHT was more strongly correlated with all plasma lactate parameters (0.61 < r < 0.84) and W-peak (r = 0.81) than with peak (V) over dot O-2 (r = 0.55). The six lactate parameters were strongly correlated with each other (0.54 < r < 0.91) and of the six lactate parameters, LTD correlated best with endurance performance (r = 0.84). Conclusions: It was concluded that plasma lactate parameters and W-peak provide better indices of endurance performance than peak (V) over dot O-2 and that, of the six descriptors of lactate increase measured in this study, LTD is most strongly related to 1-h cycling performance in trained, female cyclists.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A simple method for the measurement of pindolol enantiomers by HPLC is presented. Alkalinized serum or urine is extracted with ethyl acetate and the residue remaining after evaporation of the organic layer is then derivatised with (S)-(-)-alpha-methylbenzyl isocyanate. The diastereoisomers of derivatised pindolol and metoprolol (internal standard) are separated by high-performance liquid chromatography (HPLC) using a C-18 silica column and detected using fluorescence (excitation lambda: 215 nm, emission lambda: 320 nm). The assay displays reproducible linearity for pindolol enantiomers with a correlation coefficient of r(2) greater than or equal to 0.998 over the concentration range 8-100 ng ml(-1) for plasma and 0.1-2.5 mu g ml(-1) for urine. The coefficient of variation for accuracy and precision of the quality control samples for both plasma and urine are consistently

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Mycophenolic acid is an immunosuppressant administered as a bioavailable ester, mycophenolate mofetil. The pharmacokinetics of mycophenolic acid have been reported to be variable. Accurate measurement of concentrations of this drug could be important to adjust doses. The aim of this study was to compare the enzyme-multiplied immunoassay technique (EMIT [Dade Behring; San Jose, CA, U.S.A.]) for mycophenolic acid with a high-performance liquid chromatographic (HPLC) assay using samples collected from renal transplant recipients. The HPLC assay used solid phase extraction and a C18 stationary phase with ultraviolet (UV) detection (254 nm). The immunoassay required no manual sample preparation. Plasma samples (n = 102) from seven patients, collected at various times after a dose, were analyzed using both methods. Both assays fulfilled quality-control criteria. Higher concentrations were consistently measured in patient samples when using EMIT. The mean (+/- standard deviation [SD]) bias (EMIT-HPLC) was 1.88 +/- 0.86 mg/L. The differences in concentrations were higher in the middle of a dosage interval, suggesting that a metabolite might have been responsible for overestimation. Measurement of glucuronide concentrations by HPLC demonstrated only a weak correlation between assay differences and glucuronide concentrations. If the crossreacting substance is active, EMIT could provide a superior measure of immunosuppression; if inactive, further work is needed to improve antibody specificity. In conclusion, it was found that EMIT overestimates the concentration of mycophenolic acid in plasma samples from renal transplant recipients compared with HPLC analysis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Twenty-three patients treated with intracerebroventricular (ICV) morphine in this study not only obtained excellent pain relief without rapid increases in dose, but also experienced a reduction in morphine-related side effects. By 24 h after initiation of ICV morphine, the mean trough cerebrospinal fluid (CSF) morphine concentration (approximately 20 mu M) was 50-fold higher than the baseline concentration (approximately 0.4 mu M), and the CSF concentration of morphine-6-glucuronide (M6G) was undetectable (

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of the present investigation was to gain an understanding of the nature of the carbon contamination on the surface of standard steel transmission electron spectroscopy (TEM) specimens, the effect of exposure of a clean specimen to normal laboratory air, and the efficacy of plasma-cleaning treatments. This knowledge is a necessary prerequisite to the development of appropriate specimen preparation and/or specimen cleaning methods. X-ray photoelectron spectroscopy in combination with argon ion beam profiling was used to characterize the specimen surfaces of X65 steel and 316 stainless steel. The only clean carbon-free surface obtained was that during argon etching of the sample in the surface analysis chamber. Any exposure of a previously cleaned sample to laboratory air resulted in a rapid carbon (hydrocarbon) contamination of the sample surface and the development of surface oxidation, Plasma cleaning with subsequent exposure of the specimen to the laboratory air also resulted in a carbon-contaminated surface. This suggests that procedures of preparation of TEM specimens of steels outside an ultrahigh vacuum chamber are unlikely to result in the lowering of contamination rates on specimens to levels where measurements for carbon in the grain boundaries are possible. What is needed is a cleaning system as an integral part of the specimen insertion system into the field-emission scanning transmission electron microscope. This cleaning could be carried out by argon ion etching. Copyright (C) 2000 John Wiley & Sons, Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective. A 6 month prospective randomized double blind study was conducted to investigate hydroxychloroquine dose concentration-effect relationships in people with rheumatoid arthritis. Methods. Patients were randomized in 2 groups: one group received 200 mg hydroxychloroquine sulfate daily (A) and one group received 400 mg daily (B). Each month, 8 disease variables were assessed, adverse events recorded, and hydroxychloroquine blood concentrations determined. Results. Twenty-three patients were included: 10 in group A and 13 in group B. After 6 months of therapy, a significant improvement in disease activity was noted for 6 criteria with no statistical differences between groups: pain (assessed by a visual analog scale), joint scores (swelling and tenderness), impairment in daily Living activity (18 activities graded 0 to 8), patient assessment of disease state, and erythrocyte sedimentation rate. Hydroxychloroquine steady-state blood concentrations (Month 6) were significantly different between groups (mean +/- SD): 450.6 +/- 285.3 ng/ml (A) vs 870.3 +/- 329.3 ng/ml(B) (p = 0.0001). Steady-state concentrations were correlated with the daily dose (r = 0.63, p = 0.005), the improvement in activity of daily living (r = 0.49, p = 0.03), and the improvement in joint tenderness score (r = 0.47, p = 0.038). Conclusion. The data indicate that hydroxychloroquine is an effective therapy, but there were no further improvements observed in the group receiving 400 mg daily compared to those receiving 200 mg. There were some correlations between hydroxychloroquine steady-state blood concentrations and effects.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: This study examined the relationship between muscle glutamine, muscle glycogen, and plasma glutamine concentrations over 3 d of high-intensity exercise during which dietary carbohydrate (CHO) intake varied. Methods: Five endurance-trained men completed two exercise trials in randomized order, over a 14-d period. Each trial required subjects to perform 50 min of high-intensity continuous and interval exercise on three consecutive days while consuming a diet that provided 45% of the energy as CHO or a diet in which CHO provided 70% of the total energy. Four days of inactivity and consumption of a 55% CHO diet separated the two randomized trials. Menus and food were provided for the subjects and all food and drink consumed were weighed and recorded for later analysis. Before exercise on the first day of each trial, at the start of exercise on day 3 and on completion of exercise on day 3, muscle was biopsied from the vastus lateralis for the analysis of glutamine and glycogen concentrations. Venous blood was sampled before and twice after exercise on each day for the analysis of plasma glutamine and cortisol concentrations. Results: Mean plasma glutamine concentration was significantly higher during the 70% CHO exercise trial when compared with the 45% CHO trial (P < 0.05). Glycogen decreased by the same magnitude during both trials and there was no relationship between changes in plasma glutamine and changes in muscle glycogen concentration. Muscle glutamine concentration did not change in either trial. Conclusions: These data suggest that the influence of carbohydrate intake upon the concentration of plasma glutamine is not mediated through the concentration of intramuscular glycogen.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The volume of the primary (PCS) and secondary (SCS) circulatory system in the Atlantic cod Gadus morhua was determined using a modified dye dilution technique. Cod (N=10) were chronically cannulated in the second afferent branchial artery with PE-50 tubing. Evans Blue dye was bound to harvested fish plasma at a concentration of 1 mg dye ml(-1) plasma, and injected at a concentration of 1 mg kg(-1) body mass. Serial sampling from the cannula produced a dye dilution curve, which could be described by a double exponential decay equation. Curve analysis enabled the calculation of the primary circulatory and total distribution volume. The difference between these volumes is assumed to be the volume of the SCS. From the dilution curve, it was also possible to calculate flow rates between and within the systems. The results of these experiments suggest a plasma volume in the PCS of 3.42+/-0.89 ml 100 g(-1) body mass, and in the SCS of 1.68+/-0.35 ml 100 g(-1) body mass (mean +/- S.D.) or approximately 50% that of the PCS. Flow rates to the SCS were calculated as 2.7% of the resting cardiac output. There was an allometric relationship between body mass and blood volumes. Increasing condition factor showed a tendency towards smaller blood volumes of the PCS, expressed as percentage body mass, but this was not evident for the volume of the SCS.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Changes in plasma zinc concentration and markers of immune function were examined in a group of 10 male runners (n = 10) following a moderate increase in training over four weeks. Seven sedentary males acted as controls. Fasting blood samples were taken at rest, before (T0) and after T4) four weeks of increased (+ 16 %) training and after two weeks of reduced (- 31 %) training (W. Blood was analysed for plasma zinc concentration, differential leucocyte counts, lymphocyte subpopulations and lymphocyte proliferation using incorporation of H-3-thymidine. The runners increased their training volume by 16 % over the four weeks. When compared with the nonathletes, the runners had lower concentrations of plasma zinc (p = 0.012), CD3(+) (p = 0.042) and CD19(+) lymphocytes (p = 0.010) over the four weeks. Lymphocyte proliferation in response to Concanavalin A stimulation was greater in the runners (p = 0.0090). Plasma zinc concentration and immune markers remained constant during the study. Plasma zinc concentration correlated with total leucocyte counts in the athletes at T6 (r = -0.72, p < 0.05) and with Pokeweed mitogen stimulation in the nonathletes at T6 (r = -0.92, p < 0.05). Therefore, athletes are unlikely to benefit from zinc supplementation during periods of moderately increased training volume.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We measured plasma tafenoquine concentrations in Thai soldiers given a monthly regimen of tafenoquine to determine whether these concentrations adequately suppressed malarial infections on the Thai- Cambodian border. After receiving a treatment course of artesunate and doxycycline, 104 male soldiers were administered a loading dose of tafenoquine ( 400 mg daily for 3 days), followed by tafenoquine monthly ( 400 mg every 4 weeks) for 5 months. Consecutive monthly mean ( +/- standard deviation) trough plasma tafenoquine concentrations were 223 +/- 41, 127 +/- 29, 157 +/- 51. 120 +/- 24, and 88 +/- ng/ mL. Only 1 soldier developed malaria during the study. At the time of malaria diagnosis, his plasma tafenoquine concentration was 40 ng/ mL, which was similar to 3- fold lower than the trough concentrations of the other soldiers. Although low tafenoquine concentrations appear to be uncommon, additional investigations are needed to determine the relationship between plasma tafenoquine concentrations and suppression of malaria.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The authors describe a reverse-phase high-performance liquid chromatography-electrospray-tandem mass spectrometry method for the measurement of nicotine in human plasma. Samples (500 muL) with added deuterium-labeled d(3)-nicotine as an internal standard (IS) were treated with a 2-step process of ether extraction (6 mL) followed by back-extraction into 0.1% formic acid (50 muL). Chromatography was performed on a phenyl Novapak column with a mobile phase consisting of 50% 10 mM ammonium fortriate (pH 3.3) and acetonitrile (50:50, vol/vol). A flow rate of 0.2 mL/min resulted in a total analysis time of 5 minutes per sample. Mass spectrometric detection was by selected reactant monitoring (nicotine m/z 163.2 --> 130.2; IS m/z 166.2 --> 87.2). The assay was linear from 0.5 to 100 mug/L (r > 0.993, n = 9). The accuracy and imprecision of the method for quality control sampleswere 87.5% to 113% and < 10.2%, respectively. Interday accuracy and imprecision at the limit of quantification (0.5 mug/L) was 113% and 7.2% (n = 4). The process efficiency for nicotine in plasma was > 75%. The method described has good process efficiency, stabilized nicotine, avoided concentration steps, and most importantly minimized potential contamination. Further, we have established that water-based standards and controls are interchangeable with plasma-based samples. This method was used successfully to measure the pharmacokinetic profiles of subjects involved in the development of an aerosol inhalation drug delivery system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A simple method for the measurement of the active leflunomide metabolite A77 1726 in human plasma by HPLC is presented. The sample workup was simple, using acetonitrile for protein precipitation. Chromatographic separation of A77 1726 and the internal standard, alpha-phenylcinnamic acid, was achieved using a C-18 column with UV detection at 305 nm. The assay displayed reproducible linearity for A77 1726 with determination coefficients (r(2)) > 0.997 over the concentration range 0.5-60.0 mug/ml. The reproducibility (%CV) for intra- and inter-day assays of spiked controls was

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aims To investigate the concentration-effect relationship and pharmacokinetics of leflunomide in patients with rheumatoid arthritis (RA). Methods Data were collected from 23 RA patients on leflunomide therapy (as sole disease modifying antirheumatic drug (DMARD)) for at least 3 months. Main measures were A77 1726 (active metabolite of leflunomide) plasma concentrations and disease activity measures including pain, duration/intensity of morning stiffness, and SF-36 survey. A population estimate was sought for apparent clearance (CL/F ) and volume of distribution was fixed (0.155 l kg(-1)). Factors screened for influence on CL/F were weight, age, gender and estimated creatinine clearance. Results Significantly higher A77 1726 concentrations were seen in patients with less swollen joints and with higher SF-36 mental summary scores than in those with measures indicating more active disease (P < 0.05); concentration-effect trends were seen with five other disease activity measures. Statistical analysis of all disease activity measures showed that mean A77 1726 concentrations in groups with greater control of disease activity were significantly higher than those in whom the measures indicated less desirable control (P < 0.05). There was large between subject variability in the dose-concentration relationship. A steady-state infusion model best described the pharmacokinetic data. Inclusion of age as a covariate decreased interindividual variability (P < 0.01), but this would not be clinically important in terms of dosage changes. Final parameter estimate (% CV interindividual variability) for CL/F was 0.0184 l h(-1) (50%) (95% CI 0.0146, 0.0222). Residual (unexplained) variability (% CV) was 8.5%. Conclusions This study of leflunomide in patients using the drug clinically indicated a concentration-effect relationship. From our data, a plasma A77 1726 concentration of 50 mg l(-1) is more likely to indicate someone with less active disease than is a concentration around 30 mg l(-1). The marked variability in pharmacokinetics suggests a place for individualized dosing of leflunomide in RA therapy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We observed unexpected high plasma concentrations of tobrarriycin (48.5 and 28.1 mg/L) in fingerprick blood samples after the nebulization of tobramycin solution for inhalation (tobramycin 300 mg/5 mL, TOBI(R)) by 2 young children aged 3 years. To investigate whether dermal contamination could be the source of error, 3 adult volunteers were present during another nebulization by a third child (age 2 years). The volunteers had exposure to tobramycin by handling the nebulizer or the nebule and also by inhalation from holding the child and being in close proximity while TOBI(R) was being administered. Five blood samples by fingerprick and 2 by venipuncture were collected and assayed for tobramycin concentration. On each occasion the site was swabbed with alcohol wipes to mimic standard patient sampling methods. One site was resampled after cleaning of hands with 2% chlorhexidine gluconate and water. Tobramycin concentrations from venipuncture 1-2 hours after nebulization were all < 0.2 mg/L except for 1 result of 1.2 mg/L. The tobramycin concentrations from fingerpricks before hand washing varied between 6.8 and 172 mg/L, and after hand washing between 0.3 and 17.6 mg/L. Contamination of fingers with tobramycin is likely to have caused the error in the 2 initial cases and did cause misleadingly elevated levels in the adult volunteers. We caution that therapeutic drug monitoring of nebulized tobramycin should not be done by fingerprick sampling, and care should be taken to avoid contamination of the venipuncture site.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The conjugation of a lipoamino acid to the N-terminus of Gonadotropin releasing hormone (GnRH) produces a lipophilic peptide from which the parent GnRH peptide is released into solution on treatment with plasma and kidney enzyme preparation. Our findings show that one stereoisomer of the Laa is cleaved very rapidly, providing a bolus dose of the peptide while the opposite stereoisomer is cleaved much more slowly, providing prolonged elevation of peptide concentration. The Laa-Glu linkage appears to act as a two phase prodrug system. © 2005 Elsevier Ltd. All rights reserved.