31 resultados para Violin technique


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the 1980s the development of the doubly labelled water (DLW) technique made it possible to determine the validity of dietary assessment methods using external, independent markers of intake in free-living populations. Since then, the accuracy of self-reported energy intake (EI) has been questioned on a number of occasions as under-reporting has been found to be prevalent in many different populations. This paper is a review of investigations using the DLW technique in conjunction with self-reported EI measures in groups including adults, children and adolescents, obese persons, athletes, military personnel and trekking explorers. In studies where a person other than the subject is responsible for recording dietary intake, such as parents of young children, EI generally corresponds to DLW determined energy expenditure. However, in instances where the subjects themselves report their intake, EI is generally under-reported when compared with energy expenditure. It was originally believed that this phenomenon of under-reporting was linked to increased adiposity and body size, however, it is now apparent that other factors, such as dietary restraint and socio-economic status, are also involved. This paper therefore aims to present a more comprehensive picture of under-reporting by tying in the findings of many DLW studies with other studies focusing particularly on the characteristics and mechanisms for under-reporting. Awareness of these characteristics and mechanisms will enable researchers to obtain more accurate self-reports of EI using all dietary recording techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A technique is described to preserve the pigment found in the bodies and the intestine of some brightly coloured and darkly pigmented benedeniine capsalid monogeneans. Previous studies of these pigmented capsalids have proven difficult because the pigmentation usually disappears when the worms are fixed using preservatives containing concentrations of formalin over 5% and/or ethanol, acetic acid, chromic acid, picric acid and mercuric chloride. The technique developed here uses a fixative comprising glycerol, acetone and formalin (GAF). After fixation under light coverslip compression for three minutes, specimens are transferred to absolute acetone for three minutes and cleared in a mixture of nine parts cedar wood oil and one part absolute acetone before mounting in Canada balsam. Processing must be carried out quickly, as these chemicals will cause the pigments to fade if the specimens are exposed to them for too long. Pigmented benedeniines processed using this technique retain the distribution, intensity and colour observed in live worms. The colour and distribution of pigmentation in monogeneans may be of taxonomic importance and this technique aids preparation of whole-mounts suitable for registration as type-material.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Concerns have been raised about the reproducibility of brachial artery reactivity (BAR), because subjective decisions regarding the location of interfaces may influence the measurement of very small changes in lumen diameter. We studied 120 consecutive patients with BAR to address if an automated technique could be applied, and if experience influenced reproducibility between two observers, one experienced and one inexperienced. Digital cineloops were measured automatically, using software that measures the leading edge of the endothelium and tracks this in sequential frames and also manually, where a set of three point-to-point measurements were averaged. There was a high correlation between automated and manual techniques for both observers, although less variability was present with expert readers. The limits of agreement overall for interobserver concordance were 0.13 +/-0.65 mm for the manual and 0.03 +/-0.74 mm for the automated measurement. For intraobserver concordance, the limits of agreement were -0.07 +/-0.38 mm for observer 1 and -0.16 +/-0.55 mm for observer 2. We concluded that BAR measurements were highly concordant between observers, although more concordant using the automated method, and that experience does affect concordance. Care must be taken to ensure that the same segments are measured between observers and serially.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of gate-to-drain capacitance (C-gd) measurement as a tool to characterize hot-carrier-induced charge centers in submicron n- and p-MOSFET's has been reviewed and demonstrated. By analyzing the change in C-gd measured at room and cryogenic temperature before and after high gate-to-drain transverse field (high field) and maximum substrate current (I-bmax) stress, it is concluded that the degradation was found to be mostly due to trapping of majority carriers and generation of interface states. These interface states were found to be acceptor states at top half of band gap for n-MOSFETs and donor states at bottom half of band gap for p-MOSFETs. In general, hot electrons are more likely to be trapped in gate oxide as compared to hot holes while the presence of hot holes generates more interface states. Also, we have demonstrated a new method for extracting the spatial distribution of oxide trapped charge, Q(ot), through gate-to-substrate capacitance (C-gb) measurement. This method is simple to implement and does not require additional information from simulation or detailed knowledge of the device's structure. (C) 2001 Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Determination of the ash-free dry weight (AFDW) of marine specimens requires samples to be rinsed, soaked, and centrifuged. Problems associated with this technique were examined with the developmental stages of seastar species (Patiriella) with different modes of development. The influence of three rinsing solutions (ammonium formate [AF], filtered seawater [FSW], and reverse osmosis water [RO]) was assessed. The hypothesis that the AFDW technique is a measure of organic material was addressed by drying inorganic salts. Developmental stages of Patiriella calcar rinsed in FSW were twice as heavy as those rinsed in RO or AE indicating that samples should be rinsed in RO or AF before weighing. Soaking treatments had a significant effect on the AFDW of samples of P. calcar (planktonic developer), indicating that the rinsing period should be brief. Zygotes of Patiriella re gularis (planktonic developer) were significantly heavier than ova or gastrulae, regardless of treatment. In contrast, there were no significant differences in the AFDW of any stages or treatments of Patiriella exigua (benthic developer). This may be due to the presence of a modified fertilization envelope, which protects these benthic embryos. Inorganic salts with water of crystallization and FSW lost 20-75% and 14% of their dry weight, respectively, after ashing. We propose that salt ions may retain water, which does not evaporate during drying but is lost during ashing, resulting in the overestimation of sample AFDW. If a similar process occurs in the developmental stages of marine invertebrates, changes in the intracellular ionic composition through development may result in inaccurate estimates of biomass.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Eight species of ectomycorrhizal (ECM) fungi in the genera Amanita. Gymnoboletus, Lactarius, and Russula were isolated from subtropical plant communities in eastem Australia. Two species were isolated from each of rainforest, Nothofagus forest, Eucalyptus forest, and Eucalyptus dominated wallum (heath) forest. These communities differ strongly in their soluble soil nitrogen (N) composition. The ability of the fungi to use inorganic (nitrate, ammonium) and organic (amide, peptide, protein) nitrogen sources was determined. As the fungi did not grow in liquid culture, a 'floating culture' technique was devised that allows hyphal growth on a screen floating on liquid medium. With some exceptions, fungal biomass production in floating culture closely reflected fungal growth on solid media assessed by total colony glucosamine content. Most isolates grown in floating culture had similar glucosamine concentrations on all N sources, with isolate specific concentrations ranging from 6 to 12 mug glucosamine g(-1) DW. However, Russula spp. had up to 1.7-fold higher glucosamine concentrations when growing with glutamine or ammonium compared to nitrate, glutathione or protein. Floating cultures supplied with 0.5, 1.5. 4.5, or 10 mm N mostly produced greatest biomass with 4.5 mM N. In vitro nitrate reductase activity (NRA) ranged from very low (0.03 mumol NO2- g(-1) fw h(-1)) in Russula sp. (wallum) to high (2.16 mumol NO2- g(-1) fw h(-1)) in Gymnoboletus sp. (rainforest) and mirrored the fungi's ability to use nitrate as a N source. All Russula spp. (wallum, Nothofagus and Eucalyptus forests), Lactarills sp, (rainforest) and.4manita sp. (wallum) utilized ammonium and glutamine but had little ability to use other N sources. In contrast,Amanita species (Nothofagus and Eucalyptus forests) grew on all N sources but produced most biomass with ammonium and glutamine. Only Gymnoboletus sp. (rainforest) showed similar growth with nitrate and ammonium as N sources. Fungal N source use was not associated with taxonomic groups, but is discussed in the context of soil N sources in the different habitats.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Current noninvasive techniques for the routine and frequent quantification of peripheral lymphedema in patients are total limb volume measurement (by water immersion or by circumferential measurements) and bioelectrical impedance analysis (BIA). However both of these techniques require standardizing the measurement using a contralateral measurement from the unaffected limb, Hence these techniques are essentially restricted to unilateral lymphedema. This paper describes the results from a preliminary study to investigate an alternative approach to the analysis of the data from multiple frequency BIA to produce an index of lymphedema without the need for normalization to another body segment. Twenty patients receiving surgical treatment for breast cancer were monitored prior to surgery and again after diagnosis with unilateral lymphedema. The data recorded were total limb volume, by circumferential measurements; and BIA measurements of both limbs. From these measurements total limb volumes and extracellular fluid volumes were calculated and expressed as ratios of the affected limb to that of the unaffected limb. An index of the ratio of the extracellular fluid volume to the intracellular fluid volume was determined. This ECW/ICW index was calculated for both the affected and unaffected limbs at both measurement times. Results confirmed that the established techniques of total limb volume and extracellular fluid volume normalized to the unaffected contralateral limb were accurate in the detection of lymphedema (p < 10(-6)). Comparison of the ECW/ICW index from the affected limb after diagnosis with that from the pre-surgery measurement revealed a significant (p< 10(-6)) and considerable (75%) increase. The results of this pilot study suggest that by using multiple frequency bioelectrical impedance analysis, an index of the ECW/ICW ratio can be obtained and this index appears to have an equal, or better, sensitivity, than the other techniques in detecting lymphedema. More importantly, this index does not require normalization to another body segment and can be used to detect all types of peripheral edema including both unilateral and bilateral lymphedema.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to determine the pharmacokinetics of [C-14]diclofenac, [C-14]salicylate and [H-3]clonidine using a single pass rat head perfusion preparation. The head was perfused with 3-[N-morpholino] propane-sulfonic acid-buffered Ringer's solution. Tc-99m-red blood cells and a drug were injected in a bolus into the internal carotid artery and collected from the posterior facial vein over 28 min. A two-barrier stochastic organ model was used to estimate the statistical moments of the solutes. Plasma, interstitial and cellular distribution volumes for the solutes ranged from 1.0 mL (diclofenac) to 1.6 mL (salicylate), 2.0 mL (diclofenac) to 4.2 mL (water) and 3.9 mL (salicylate) to 20.9 mL (diclofenac), respectively. A comparison of these volumes to water indicated some exclusion of the drugs from the interstitial space and salicylate from the cellular space. Permeability-surface area (PS) products calculated from plasma to interstitial fluid permeation clearances (CLPI) (range 0.02-0.40 mL s(-1)) and fractions of solute unbound in the perfusate were in the order: diclofenac>salicylate >clonidine>sucrose (from 41.8 to 0.10 mL s(-1)). The slow efflux of diclofenac, compared with clonidine and salicylate, may be related to its low average unbound fraction in the cells. This work accounts for the tail of disposition curves in describing pharmacokinetics in the head.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Presently the surgical approach to the adrenal gland is in a state of flux. While the traditional approach to the adrenal gland has been the open transabdominal technique, more recently laparoscopic approaches, particularly via the transabdominal route, have increasingly been utilized. However, laparoscopic intervention for the adrenal gland can be problematic in certain circumstances, particularly for large adrenal masses and in instances of adrenal malignancies. Methods: In this report we describe the use of hand-assisted laparoscopic adrenalectomy as an alternative minimal invasive surgical approach to the adrenal gland. Hand-assisted laparoscopic adrenalectomy using the HandPort system (Smith & Nephew, Sydney, Australia) was undertaken in three patients requiring adrenalectomy for mass lesions including one patient with Conn's syndrome. Results: In all three cases, surgery proceeded promptly and uneventfully. In the present paper, the details of the technique of hand-assisted adrenalectomy are described. This is the first report in the world literature of this new technique for the adrenal gland. Conclusions: Hand-assisted laparoscopic adrenalectomy is an easily performed technique, which can be completed within a short operative time span and which has the advantage of providing intraoperative tactile localization for the adrenal gland. It may be particularly applicable for large adrenal tumours, yet only involves the performance of a small abdominal incision. Postoperative recovery is comparable with that reported for the laparoscopic-only technique. Hand-assisted adrenalectomy is a new technique which has great potential and which warrants further evaluation.