40 resultados para Pressure suits.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Experimental data for E. coli debris size reduction during high-pressure homogenisation at 55 MPa are presented. A mathematical model based on grinding theory is developed to describe the data. The model is based on first-order breakage and compensation conditions. It does not require any assumption of a specified distribution for debris size and can be used given information on the initial size distribution of whole cells and the disruption efficiency during homogenisation. The number of homogeniser passes is incorporated into the model and used to describe the size reduction of non-induced stationary and induced E. coil cells during homogenisation. Regressing the results to the model equations gave an excellent fit to experimental data ( > 98.7% of variance explained for both fermentations), confirming the model's potential for predicting size reduction during high-pressure homogenisation. This study provides a means to optimise both homogenisation and disc-stack centrifugation conditions for recombinant product recovery. (C) 1997 Elsevier Science Ltd.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A significant loss in electron probe current can occur before the electron beam enters the specimen chamber of an environmental scanning electron microscope (ESEM). This loss results from electron scattering in a gaseous jet formed inside and downstream (above) the pressure-limiting aperture (PLA), which separates the high-pressure and high-vacuum regions of the microscope. The electron beam loss above the PLA has been calculated for three different ESEMs, each with a different PLA geometry: an ElectroScan E3, a Philips XL30 ESEM, and a prototype instrument. The mass thickness of gas above the PLA in each case has been determined by Monte Carlo simulation of the gas density variation in the gas jet. It has been found that the PLA configurations used in the commercial instruments produce considerable loss in the electron probe current that dramatically degrades their performance at high chamber pressure and low accelerating voltage. These detrimental effects are minimized in the prototype instrument, which has an optimized thin-foil PLA design.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There are many methods for the analysis and design of embedded cantilever retaining walls. They involve various different simplifications of the pressure distribution to allow calculation of the limiting equilibrium retained height and the bending moment when the retained height is less than the limiting equilibrium value, i.e. the serviceability case. Recently, a new method for determining the serviceability earth pressure and bending moment has been proposed. This method makes an assumption defining the point of zero net pressure. This assumption implies that the passive pressure is not fully mobilised immediately below the excavation level. The finite element analyses presented in this paper examine the net pressure distribution on walls in which the retained height is less, than the limiting equilibrium value. The study shows that for all practical walls, the earth pressure distributions on the front and back of the wall are at their limit values, Kp and K-a respectively, when the lumped factor of safety F-r is less than or equal to2.0. A rectilinear net pressure distribution is proposed that is intuitively logical. It produces good predictions of the complete bending moment diagram for walls in the service configuration and the proposed method gives results that have excellent agreement with centrifuge model tests. The study shows that the method for determining the serviceability bending moment suggested by Padfield and Mair(1) in the CIRIA Report 104 gives excellent predictions of the maximum bending moment in practical cantilever walls. It provides the missing data that have been needed to verify and justify the CIRIA 104 method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Palpation for tenderness forms an important part of the manual therapy assessment for musculoskeletal dysfunction, In conjunction with other testing procedures it assists in establishing the clinical diagnosis. Tenderness in the thoracic spine has been reported in the literature as a clinical feature in musculoskeletal conditions where pain and dysfunction are located primarily in the upper quadrant. This study aimed to establish whether pressure pain thresholds (PPTs) of the mid-thoracic region of asymptomatic subjects were naturally lower than those of the cervical and lumbar areas. A within-subject study design was used to examine PPT at four spinal levels C6, T4, T6, and L4 in 50 asymptomatic volunteers. Results showed significant (P < 0.001) regional differences. PPT values increased in a caudal direction. The cervical region had the lowest PPT scores, that is was the most tender. Values increased in the thoracic region and were highest in the lumbar region. This study contributes to the normative data on spinal PPT values and demonstrates that mid-thoracic tenderness relative to the cervical spine is not a normal finding in asymptomatic subjects. (C) 2001 Harcourt Publishers Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Expansion tubes operating at total flow enthalpies of 100 MJ kg(-1) or more have characteristical test times of 30-50 mus. Under these conditions, the response time of the Pitot pressure measuring device is critical when performing flow calibration studies. The conventional technique of using a commercial pressure transducer protected by shielding has not always proven to be effective, due to the relatively large (and variable) response time caused by the shielding. A device called the stress wave bar gauge has been designed and calibrated and shown to be an effective way to measure the Pitot pressure with a response time of only 2-3 mus.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we develop a theory for diffusion and flow of pure sub-critical adsorbates in microporous activated carbon over a wide range of pressure, ranging from very low to high pressure, where capillary condensation is occurring. This theory does not require any fitting parameter. The only information needed for the prediction is the complete pore size distribution of activated carbon. The various interesting behaviors of permeability versus loading are observed such as the maximum permeability at high loading (occurred at about 0.8-0.9 relative pressure). The theory is tested with diffusion and flow of benzene through a commercial activated carbon, and the agreement is found to be very good in the light that there is no fitting parameter in the model. (C) 2001 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

1. An elevation in blood pressure has been consistently observed 24 h after adrenocorticotropic hormone (ACTH) administration and is caused by increased ACTH-stimulated cortisol secretion, in association with increased cardiac output. The aim of the present study was to investigate the previously undefined time of onset of this increase in blood pressure in normal humans. 2. Ten normal healthy volunteers received 250 mug ACTH-[1-24], in 500 mL normal saline, infused at a constant rate over 8 h. Six subjects also received a placebo infusion (normal saline only). Blood pressure, heart rate and cortisol levels were determined hourly. Adrenocorticotropic hormone (ACTH-[1-24] plus native ACTH) was measured at 0, 1, 7 and 8 h. 3. Infusion of ACTH-[1-24] produced maximal secretion rates of cortisol, resulting in a mean peak plasma level of 985 +/- 46 nmol/L at 8 h. In response, blood pressure and heart rate rose significantly by 2 h and remained generally elevated for the duration of the infusion. 4. The early onset of haemodynamic responses is consistent with classical steroid receptor-mediated genomic mechanisms, but could be due non-genomic mechanisms. 5. The cardiovascular consequences of therapeutic use of ACTH are well recognized. This results of the present study suggest that even diagnostic administration of ACTH, delivered over a few hours, may raise blood pressure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In a prospective study 105 patients with symptoms of stress incontinence underwent video-urodynamic testing, including resting urethral pressure profilometry and translabial ultrasound. The urethral pressure profile (UPP) included maximum urethral closure pressure (MUCP), functional length (FL) and area under the curve (AUC). Ultrasound parameters included urethral thickness, urethral rotation and bladder neck descent, as well as funneling/opening of the internal urethral meatus on Valsalva maneuver. Levator contraction strength was assessed measuring the cranioventral displacement of the internal meatus. Negative correlations between UPP data and age, parity and previous surgery were observed which were consistent with literature data. There was a positive correlation :between the urethral AP diameter on ultrasound and the MUCP, which agrees with reports showing reduced sphincter thickness or volume in stress-incontinent women. Hypermobility on ultrasound did not correlate with UPP data. However, a lower MUCP correlated with extensive opening of the bladder neck. Finally, there was a trend towards poorer pelvic floor function with lower MUCP measurements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The in vitro efficacy of several fungicides against Botryosphaeria dothidea (syn. Dothiorella dominicana) and their in vivo efficacy in controlling mango cv. Kensington Pride stem-end rot on partial-pressure infiltration v. dip treatment of green mature fruit was evaluated. In vitro sensitivity of B. dothidea to Benlate (benomyl), Sportak (prochloraz) and Scala (pyrimethanil) at 10 dilutions of the manufacturer's recommended rate was first determined at typical cold (13degreesC) and shelf (23degreesC) storage temperatures. The effectiveness of partial-pressure infiltration and conventional hot (52degreesC) or cold (26degreesC) dipping of fruit after harvest was then evaluated using the commercially recommended rate for each fungicide. In vitro, Benlate and Sportak prevented the growth of B. dothidea at both storage temperatures and at all concentrations, while Scala partially controlled growth of the pathogen. Benlate was the most effective fungicide for stem-end rot control. Sportak and Scala resulted in stem-end rot control when applied by partial-pressure infiltration, but not as dips. Partial-pressure infiltration holds promise for enhancing the efficacy of otherwise less effective but alternative fungicides for control of stem-end rot diseases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Twin and family studies have shown that genetic effects explain a relatively high amount of the phenotypic variation in blood pressure. However, many studies have not been able to replicate findings of association between specific polymorphisms and diastolic and systolic blood pressure. Methods In a structural equation-modelling framework the authors investigated longitudinal changes in repeated measures of blood pressures in a sample of 298 like-sexed twin pairs from the population-based Swedish Twin Registry. Also examined was the association between blood pressure and polymorphisms in the angiotensin-I converting enzyme and the angiotensin 11 receptor type 1 with the 'Fulker' test Both linkage and association were tested simultaneously revealing whether the polymorphism is a Quantitative Trait Locus (QTL) or in linkage disequilibrium with the QTL. Results Genetic influences explained up to 46% of the phenotypic variance in diastolic and 63% of the phenotypic variance in systolic blood pressure. Genetic influences were stable over time and contributed up to 78% of the phenotypic correlation in both diastolic and systolic blood pressure. Non-shared environmental effects were characterised by time specific influences and little transmission from one time point to the next. There was no significant linkage and association between the polymorphisms and blood pressure. Conclusions There is a considerable genetic stability in both diastolic and systolic blood pressure for a 6-year period of time in adult life. Non-shared environmental influences have a small long-term effect Although associations with the polymorphisms could not be replicated, results should be interpreted with caution due to power considerations. (C) 2002 Lippincott Williams Wilkins.