91 resultados para Fetal echocardiography


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Echocardiographic analysis of regional left ventricular function is based upon the assessment of radial motion. Long-axis motion is an important contributor to overall function. but has been difficult to evaluate clinically until the recent development of tissue Doppler techniques. We sought to compare the standard visual assessment of radial motion with quantitative tissue Doppler measurement of peak systolic velocity. timing and strain rate (SRI) in 104 patients with known or suspected coronary artery disease undergoing dobutamine stress echocardiography (DbE). A standard DbE protocol was used with colour tissue Doppler images acquired in digital cine-loop format. peak systolic velocity (PSV), time to peak velocity (TPV) and SRI were assessed off-line by an independent operator. Wall motion was assessed by an experienced reader. Mean PSV, TPV and SRI values were compared with wall motion and the presence of coronary artery disease by angiography. A further analysis included assessing the extent of jeopardized myocardium by comparing average values of PSV, TPV and SRI against the previously validated angiographic score. Segments identified as having normal and abnormal radial wall motion showed significant differences in mean PSV (7.9 +/- 3.8 and 5.9 +/- 3.3 cm/s respectively; P < 0.001), TPV (84 40 and 95 +/- 48 ms respectively; P = 0.005) and SRI (- 1.45 +/- 0.5 and - 1.1 +/- 0.9 s(-1) respectively; P < 0.001). The presence of a stenosed subtending coronary artery was also associated with significant differences from normally perfused segments for mean PSV (8.1 3.4 compared with 5.7 +/- 3.7 cm/s; P < 0.001), TPV (78 50 compared with 92 +/- 45 ms; P < 0.001) and SRI (- 1.35 0.5 compared with - 1.20 +/- 0.4 s(-1); P = 0.05). PSV, TPV and SRI also varied significantly according to the extent of jeopardized myocardium within a vascular territory. These results suggest that peak systolic velocity, timing of contraction and SRI reflect the underlying physiological characteristics of the regional myocardium during DbE, and may potentially allow objective analysis of wall motion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES We sought to find out whether dobutamine echocardiography (DbE) could provide independent prediction of total and cardiac mortality, incremental to clinical and angiographic variables. BACKGROUND Existing outcome studies with DbE have examined composite end points, rather than death, over a relatively short follow-up. METHODS Clinical and stress data were collected in 3,156 patients (age 63 +/- 12 years, 1,801 men) undergoing DbE. Significant stenoses (>50% diameter) were identified in 70% of 1,073 patients undergoing coronary angiography. Total and cardiac mortality were identified over nine years of follow-up (mean 3.8 +/- 1.9). Cox models were used to analyze the effect of ischemia and other variables, independent of other determinants of mortality. RESULTS The dobutamine echocardiogram was abnormal in 1,575 patients (50%). Death occurred in 716 patients (23%), 259 of whom (8%) were thought to have died from cardiac causes. Patients with normal DbE had a total mortality of 8% per year and a cardiac mortality of 1% per year over the first four years of follow-up. Ischemia and the extent of abnormal wall motion were independent predictors of cardiac death, together with age and heart failure. In sequential Cox models, the predictive power of clinical data alone (model chi-square 115) was strengthened by adding the resting left ventricular function (model chi-square 138) and the results of DbE (model chi-square 181). In the subgroup undergoing coronary angiography, the power of the model was increased to a minor degree by the addition of coronary anatomy data. CONCLUSIONS Dobutamine echocardiography is an independent predictor of death, incremental to other data. While a normal dobutamine echocardiogram predicts low risk of cardiac death ton the order of 1% per year), this risk increases with the extent of abnormal wall motion at rest and stress, (J Am Coil Cardiol 2001;37:754-60) (C) 2001 by the American College of Cardiology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study is to compare the accuracy of sonographic estimation of fetal weight of macrosomic babies in diabetic vs non-diabetic pregnancies. Ali babies weighing 4000 g or more at birth, and who had ultrasound scans performed within one week of delivery were included in this retrospective study. Pregnancies with diabetes mellitus were compared to those without diabetes mellitus. The mean simple error (actual birthweight - estimated fetal weight); mean standardised absolute error (absolute value of simple error (g)/actual birthweight (kg)); and the percentage of estimated birthweight falling within 15% of the actual birthweight between the two groups were compared. There were 9516 deliveries during the study period. Of this total 1211 (12.7 %) babies weighed 4000 g or more. A total of 56 non-diabetic pregnancies and 19 diabetic pregnancies were compared. The average sonographic estimation of fetal weight in diabetic pregnancies was 8 % less than the actual birthweight, compared to 0.2 % in the non-diabetic group (p < 0.01). The estimated fetal weight was within 15% of the birthweight in 74 % of the diabetic pregnancies, compared to 93 % of the non-diabetic pregnancies (p < 0.05). In the diabetic group, 26.3 % of the birthweights were underestimated by more than 15 %, compared to 5.4 % in the non-diabetic group (p < 0.05). In conclusion, the prediction accuracy of fetal weight estimation using standard formulae in macrosomic fetuses is significantly worse in diabetic pregnancies compared to non-diabetic pregnancies. When sonographic fetal weight estimation is used to influence the mode of delivery for diabetic women, a more conservative cut-off needs to be considered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

If the Internet could be used as a method of transmitting ultrasound images taken in the field quickly and effectively, it would bring tertiary consultation to even extremely remote centres. The aim of the study was to evaluate the maximum degree of compression of fetal ultrasound video-recordings that would not compromise signal quality. A digital fetal ultrasound videorecording of 90 s was produced, resulting in a file size of 512 MByte. The file was compressed to 2, 5 and 10 MByte. The recordings were viewed by a panel of four experienced observers who were blinded to the compression ratio used. Using a simple seven-point scoring system, the observers rated the quality of the clip on 17 items. The maximum compression ratio that was considered clinically acceptable was found to be 1:50-1:100. This produced final file sizes of 5-10 MByte, corresponding to a screen size of 320 x 240 pixels, running at 15 frames/s. This study expands the possibilities for providing tertiary perinatal services to the wider community.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have established a realtime fetal tele-ultrasound consultation service in Queensland, which has been integrated into our routine clinical practice, The service, which uses ISDN transmission at 384 kbit/s, allows patients in Townsville to be examined by subspecialists in Brisbane, 1500 km away. For the 90 tele-ultrasound consultations performed for the first 71 patients, 90% of the babies have been delivered, and outcome data have been received on all the pregnancies. All significant anomalies and diagnoses have been confirmed. The referring clinicians would have physically referred 24 of the 71 patients to Brisbane in the absence of telemedicine. A crude cost-benefit calculation suggests that the tele-ultrasound service resulted in a net saving of A$6340, and at the same time enabled almost four times the number of consultations to be carried out.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although cardiac dysfunction in hereditary hemochromatosis (HHC) can be evaluated by conventional echocardiography, findings are often not specific. To test the hypothesis that the assessment of (1) conventional Doppler left ventricular filling indexes and (2) intrinsic elastic properties of the myocardium by Doppler tissue echocardiography can both enhance the accuracy of echocardiographic diagnosis of cardiac involvement in HHC, a group of 18 patients with HHC (mean age 50+/-7 years) and 22 age-matched healthy subjects were studied. The following indexes were characteristic for HHC: (1) the duration of atrial reversal measured from pulmonary venous flow (ms) was longer(118+/-20 vs 90+/-16; P

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article examines the current status of fetal pulse oximetry (FPO) as a means of intrapartum assessment of fetal wellbeing. FPO has been developed to a stage where it is a safe and accurate indicator of intrapartum fetal oxygenation. In general, sliding the FPO sensor along the examiner's fingers and through the cervix, to lie alongside the fetal cheek or temple is easy The recent publication of a randomised controlled trial (RCT) of FPO versus conventional intrapartum monitoring has validated its use to reduce caesarean section rates for nonreassuring fetal status. An Australian multicentre RCT is currently underway. Maternal satisfaction rates with FPO are high. FPO may be used during labour when the electronic fetal heart rate trace is nonreassuring or when conventional monitoring is unreliable, such as with fetal arrhythmias. If the fetal oxygen saturation (FSpO(2)) values are < 30%, prompt obstetric intervention is indicated, such as fetal scalp blood sampling or delivery FSpO(2) monitoring should not form the sole basis of intrapartum fetal welfare assessment. Rather, the whole clinical picture should be considered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of maternal epidural analgesia in labor may be associated with nonreassuring fetal heart rate (FHR) patterns. Fetal oxygen saturation (FSpO(2)) monitoring may improve assessment of fetal well-being during this time. Mean FSpO(2) values were compared over seven 5-minute epochs: 5 minutes prior to an epidural event (combined insertion of epidural/top-up epidural analgesia and infusion pump bolus), to 30 minutes following the event, including possible effects of maternal position and FHR pattern on FSpO(2) values. Mean FSpO(2) values were significantly different between the 5 minutes prior (49.5%) versus 16-20 minutes (44.3%, p

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES The goal of this study was to determine whether wall stress at rest and during stress could explain the influence of left ventricular (LV) morphology on the accuracy of dobutamine stress echocardiography (DSE). BACKGROUND The sensitivity of DSE appears to be reduced in patients with concentric remodeling, but the cause of this finding is unclear. METHODS We studied 161 patients without resting wall motion abnormalities who underwent DSE and coronary angiography. Patients were classified into four groups according to relative wan thickness (normal

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Diastolic dysfunction induced by ischemia may alter transmitral blood flow, but this reflects global ventricular function, and pseudonormalization may occur with increased preload. Tissue Doppler may assess regional diastolic function and is relatively load-independent, but limited data exist regarding its application to stress testing. We sought to examine the stress response of regional diastolic parameters to dobutomine echocardiography (DbE). Methods Sixty-three patients underwent study with DbE: 20 with low probability of coronary artery disease (CAD) and 43 with CAD who underwent angiography. A standard DbE protocol was used, and segments were categorized as ischemic, scar, or normal. Color tissue Doppler was acquired at baseline and peak stress, and waveforms in the basal and mid segments were used to measure early filling (Em), late filling (Am), and E deceleration time. Significant CAD was defined by stenoses >50% vessel diameter. Results Diastolic parameters had limited feasibility because of merging of Em and Am waves at high heart rates and limited reproducibility. Nonetheless, compared with normal segments, segments subtended with significant stenoses showed a lower Em velocity at rest (6.2 +/- 2.6 cm/s vs 4.8 +/- 2.2 cm/s, P < .0001) and peak (7.5 +/- 4.2 cm/s vs 5.1 +/- 3.6 cm/s, P < .0001), Abnormal segments also showed a shorter E deceleration time (51 +/- 27 ms vs 41 +/- 27 ms, P = .0001) at base and peak. No changes were documented in Am. The same pattern was seen with segments identified as ischemic with wall motion score. However, in the absence of ischemia, segments of patients with left ventricular hypertrophy showed a lower Em velocity, with blunted Em responses to stress. Conclusion Regional diastolic function is sensitive to ischemia. However, a number of practical limitations limit the applicability of diastolic parameters for the quantification of stress echocardiography.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Tissue Doppler may be used to quantify regional left ventricular function but is limited by segmental variation of longitudinal velocity from base to apex and free to septal walls. We sought to overcome this by developing a composite of longitudinal and radial velocities. Methods and Results. We examined 82 unselected patients undergoing a standard dobutamine echocardiogram. Longitudinal velocity was obtained in the basal and mid segments of each wall using tissue Doppler in the apical views. Radial velocities were derived in the same segments using an automated border detection system and centerline method with regional chords grouped according to segment location and temporally averaged. In 25 patients at low probability of coronary disease, the pattern of regional variation in longitudinal velocity (higher in the septum) was the opposite of radial velocity (higher in the free wall) and the combination was homogenous. In 57 patients undergoing angiography, velocity in abnormal segments was less than normal segments using longitudinal (6.0 +/- 3.6 vs 9.0 +/- 2.2 cm/s, P = .01) and radial velocity (6.0 +/- 4.0 vs 8.0 +/- 3.9 cm/s, P = .02). However, the composite velocity permitted better separation of abnormal and normal segments (13.3 +/- 5.6 vs 17.5 +/- 4.2 cm/s, P = .001). There was no significant difference between the accuracy of this quantitative approach and expert visual wall motion analysis (81% vs 84%, P = .56). Conclusion: Regional variation of uni-dimensional myocardial velocities necessitates site-specific normal ranges, probably because of different fiber directions. Combined analysis of longitudinal and radial velocities allows the derivation of a composite velocity, which is homogenous in all segments and may allow better separation of normal and abnormal myocardium.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE - This study sought to determine whether stress echocardiography using exercise (when feasible) or dobutamine echo could be used to predict mortality in patients with diabetes. RESEARCH DESIGN AND METHODS - Stress echo was performed in 937 patients with diabetes (aged 59 +/- 13 years, 529 men) for symptom evaluation (42%) and follow-up of known coronary artery disease (CAD) (58%). Stress echocardiography using exercise was performed in 333 patients able to exercise maximally, and dobutamine echo using a standard dobutamine stress was used in 604 patients. Patients were followed for less than or equal to9 years (mean 3.9 +/- 2.3) for all-cause mortality. RESULTS - Normal studies were obtained in 567 (60%) patients; 29% had resting left ventricular (LV) dysfunction, and 25% had ischemia. Abnormalities were confined to one territory in 183 (20%) patients and to multiple territories in 187 (20%) patients. Death (in 275 [29%] patients) was predicted by referral for pharmacologic stress (hazard ratio [HR] 3.94, P < 0.0001), ischemia (1.77, P <0.0001), age (1.02, P = 0.002), and heart failure (1.54, P = 0.01). The risk of death in patients With a normal scan was 4% per year, and this was associated with age and selection for pharmacologic stress testing. In stepwise models replicating the sequence of clinical evaluation, the predictive power of independent clinical predictors (age, selection for pharmacologic stress, previous infarction, and heart failure; model chi(2) = 104.8) was significantly enhanced by addition of stress echo data (model chi(2) = 122.9). CONCLUSIONS - The results of stress echo are independent predictors of death in diabetic patients with known or suspected CAD.. Ischemia adds risk that is incremental to clinical risks and LV dysfunction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Quantification of stress echocardiography may overcome the training requirements and subjective nature of visual wall motion score (WMS) assessment, but quantitative approaches may be difficult to apply and require significant time for image processing. The integral of long-axis myocardial velocity is displacement, which may be represented as a color map over the left ventricular myocardium. This study was designed to explore the feasibility and accuracy of measuring long-axis myocardial displacement, derived from tissue Doppler, for the detection of coronary artery disease (CAD) during dobutamine stress echocardiography (DBE). One hundred thirty patients underwent standard DBE, including 30 patients at low risk of CAD, 30 patients with normal coronary angiography (both groups studied to define normal ranges of displacement), and 70 patients who underwent coronary angiography in whom the accuracy of normal ranges was tested. Regional myocardial displacement was obtained by analysis of color tissue Doppler apical images acquired at peak stress. Displacement was compared with WMS, and with the presence of CAD by angiography. The analysis time was 3.2 +/- 1.5 minutes per patient. Segmental displacement was correlated with wall motion (normal 7.4 +/- 3.2 mm, ischemia 5.8 +/- 4.2 mm, viability 4.6 +/- 3.0 mm, scar 4.5 +/- 3.5 mm, p <0.001). Reversal of normal base-apex displacement was an insensitive (19%) but specific (90%) marker of CAD. The sum of displacements within each vascular territory had a sensitivity and specificity of 89% and 79%, respectively, for prediction of significant CAD, compared with 86% and 78%, respectively, for WMS (p = NS). The displacements in the basal segments had a sensitivity and specificity of 83% and 78%, respectively (p = NS). Regional myocardial displacement during DBE is feasible and offers a fast and accurate method for the diagnosis of CAD. (C),2002 by Excerpta Medica, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE - To assess the timing of fetal growth spurt among pre-existing diabetic pregnancies (types 1 and 2) and its relationship with diabetic control. To correlate fetal growth acceleration with factors that might influence fetal growth. RESEARCH DESIGN AND METHODS - This retrospective study involved all pregestational diabetic pregnancies delivered at a tertiary obstetric hospital in Australia between 1 January 1994 and 31 December 1999. Pregnancies with major congenital fetal anomalies, multiple pregnancies, small-for-gestational-age pregnancies (90th centile for gestation) were compared with babies with normal birth weights. RESULTS- A total of 101 diabetic pregnancies were included. Diabetic mothers, who had LGA babies, had significantly higher prepregnancy body weight and BMI (P < 0.05). There were no differences in maternal age or parity among the two groups. There were also no differences in the first-, second-, and third-trimester HbA(1c) levels between the two groups. The abdominal circumference z-scores were significantly higher for LGA babies from 18 weeks and thereafter. The differences increased progressively as the gestation advanced. Maximum difference was noted in the third trimester (30-38 weeks). CONCLUSIONS - Fetal growth acceleration in LGA fetuses of diabetic mothers starts in the second trimester, from as early as 18 weeks. In this study, glucose control did not appear to have a direct effect on the incidence of LGA babies, and such observation might result from the effects of other confounding factors.