37 resultados para Brix extraction
Resumo:
The hepatotoxin cylindrospermopsin (CYN) has been isolated from the cyanobacterium Cylindrospermopsis raciborskii (C. raci.). Efforts to study this toxin have been hampered by the time-consuming requirement to extract it from cultures of the organism. It is usually extracted from lyophilized cells collected from a laboratory culture. Our preliminary work suggested far more of the toxin is available in solution in the culture media than in the cells collected. We have therefore investigated the use of commercially available solid phase extraction sorbents to extract CYN from culture media in which C. raci. has been grown. A range of reverse phase and ion-exchange sorbents were tested across a range of pHs for their ability to retain CYN without success. Subsequently, graphitized carbon cartridges were found to retain CYN strongly. Elution with 5% formic acid in methanol allowed the CYN to be regained for final purification by HPLC. Deoxy-CYN, an analog of CYN can also be extracted using this procedure. (C) 2001 John Wiley & Sons, Inc.
Resumo:
A new method to extract MOSFET's threshold voltage VT by measurement of the gate-to-substrate capacitance C-gb of the transistor is presented. Unlike existing extraction methods based on I-V data, the measurement of C-gb does not require de drain current to now between drain and source thus eliminating the effects of source and drain series resistance R-S/D, and at the same time, retains a symmetrical potential profile across the channel. Experimental and simulation results on devices with different sizes are presented to justify the proposed method.
Resumo:
This article proposes a more accurate approach to dopant extraction using combined inverse modeling and forward simulation of scanning capacitance microscopy (SCM) measurements on p-n junctions. The approach takes into account the essential physics of minority carrier response to the SCM probe tip in the presence of lateral electric fields due to a p-n junction. The effects of oxide fixed charge and interface state densities in the grown oxide layer on the p-n junction samples were considered in the proposed method. The extracted metallurgical and electrical junctions were compared to the apparent electrical junction obtained from SCM measurements. (C) 2002 American Institute of Physics.
Resumo:
Secreted anterior adhesives, used for temporary attachment to epithelial surfaces of fishes (skin and gills) by some monogenean (platyhelminth) parasites have been partially characterised. Adhesive is composed of protein. Amino acid composition has been determined for seven monopisthocotylean monogeneans. Six of these belong to the Monocotylidae and one species, Entobdella soleae (van Beneden et Hesse, 1864) Johnston, 1929, is a member of the Capsalidae. Histochemistry shows that the adhesive does not contain polysaccharides, including acid mucins, or lipids. The adhesive before secretion and in its secreted form contains no dihydroxyphenylalanine (dopa). Secreted adhesive is highly insoluble, but has a soft consistency and is mechanically removable from glass surfaces. Generally there are high levels of glycine and alanine, low levels of tyrosine and methionine, and histidine is often absent. However, amino acid content varies between species, the biggest differences evident when the monocotylid monogeneans were compared with E. soleae. Monogenean adhesive shows similarity in amino acid profile with adhesives from starfish, limpets and barnacles. However, there are some differences in individual amino acids in the temporary adhesive secretions of, on the one hand, the monogeneans and, on the other hand, the starfish and limpets. These differences may reflect the fact that monogeneans, unlike starfish and barnacles, attach to living tissue (tissue adhesion). A method of extracting unsecreted adhesive was investigated for use in further characterisation studies on monogenean glues.
Resumo:
A new cloud-point extraction and preconcentration method, using a cationic, surfactant, Aliquat-336 (tricaprylyl-methy;ammonium chloride), his-been developed for the determination of cyanobacterial toxins, microcystins, in natural waters. Sodium sulfate was used to induce phase separation at 25 degreesC. The phase behavior of Aliquat-336 with respect to concentration of Na2SO4 was studied. The cloud-point system revealed a very high phase volume ratio compared to other established systems of nonionic, anionic, and cationic surfactants: At pH 6-7, it showed an outstanding selectivity in ahalyte extraction for anionic species. Only MC-LR and MC-YR, which are known to be predominantly anionic, were extracted (with averaged recoveries of 113.9 +/- 9% and 87.1 +/- 7%, respectively). MC-RR, which is likely to be amphoteric at the above pH range, was. not cle tectable in.the extract. Coupled to HPLC/UV separation and detection, the cloud-point extraction method (with 2.5 mM Aliquat-336 and 75 mM Na2SO4 at 25 degreesC) offered detection limits of 150 +/- 7 and 470 +/- 72 pg/mL for MC-LR and MC-YR, respectively, in 25 mL of deionized water. Repeatability of the method was 7.6% for MC-LR and 7.3% for MC-YR: The cloud-point extraction process can be. completed within 10-15 min with no cleanup steps required. Applicability of the new method to the determination of microcystins in real samples was demonstrated using natural surface waters, collected from a local river and a local duck pond spiked with realistic. concentrations of microcystins. Effects of salinity and organic matter (TOC) content in the water sample on the extraction efficiency were also studied.
Resumo:
A jugular venotomy technique was developed to attempt extraction of Dirofilaria immitis in cats. Seven cats were first examined by cardiac ultrasound to establish the location of adult D. immitis that had been inserted by jugular venotomy. The efficiency of an extractor catheter in surgically removing filariae similarly inserted into 13 experimental cats was then assessed. A mean extraction success rate of 96% was achieved. This technique would seem to be worthy of clinical use provided the filariae are in the right atrial area.
Resumo:
Measurement of hepatic oxygen extraction was performed on six healthy Greyhound dogs over a two hour period. The Greyhounds were anaesthetised and a right subcostal surgical incision performed. Ultrasonic flow transducers were used to measure flow rate in the hepatic artery and the portal vein. The blood oxygen tensions in arterial blood and in the portal and hepatic veins were also measured. Hepatic oxygen extraction remained stable throughout the study, despite a steady decline in arterial blood pressure. The methodology described in this study provides a direct measure of oxygen uptake by the liver in the dog and could readily be used to investigate hepatic uptake of drugs. (C) 2003 Elsevier Ltd. All rights reserved.
Resumo:
A simple, rapid method is described for the extraction of large numbers of free-living nematodes from estuarine sediments. This method does not physically or chemically alter or damage the nematodes, but instead relies on their downward movement through a filtering layer of double ply tissue paper and into aerated water-filled trays. Seven trials each with 10 trays kept at 25degreesC for an initial period of 24 h yielded 3985 live nematodes l(-1) (+/-511.5 standard deviation) of estuarine sediment, free of sediment and with minimal debris. Time effects were statistically significantly different, with the same 10 trays yielding another 1259 nematodes l(-1) (+/-413.4) when kept for a second period of 24 h at the same temperature. Temperature effects were also significant, and 7 trials each with 10 trays kept for 24 h at 20-21degreesC, produced a lower yield of 2160 nematodes l(-1) (+/-532.7) of sediment. The method is expected to be of use in nematode extractions from both estuarine and marine sediments.
Resumo:
Nonalcoholic fatty liver disease is the most common of all liver diseases. The hepatic disposition [H-3]palmitate and its low-molecular-weight metabolites in perfused normal and steatotic rat liver were studied using the multiple indicator dilution technique and a physiologically based slow diffusion/bound pharmacokinetic model. The steatotic rat model was established by administration of 17alpha-ethynylestradiol to female Wistar rats. Serum biochemistry markers and histology of treated and normal animals were assessed and indicated the presence of steatosis in the treatment group. The steatotic group showed a significantly higher alanine aminotransferase-to-aspartate aminotransferase ratio, lower levels of liver fatty acid binding protein and cytochrome P-450, as well as microvesicular steatosis with an enlargement of sinusoidal space. Hepatic extraction for unchanged [H-3]palmitate and production of low-molecular-weight metabolites were found to be significantly decreased in steatotic animals. Pharmacokinetic analysis suggested that the reduced extraction and sequestration for palmitate and its metabolites was mainly attributed to a reduction in liver fatty acid binding protein in steatosis.
Resumo:
Single shortest path extraction algorithms have been used in a number of areas such as network flow and image analysis. In image analysis, shortest path techniques can be used for object boundary detection, crack detection, or stereo disparity estimation. Sometimes one needs to find multiple paths as opposed to a single path in a network or an image where the paths must satisfy certain constraints. In this paper, we propose a new algorithm to extract multiple paths simultaneously within an image using a constrained expanded trellis (CET) for feature extraction and object segmentation. We also give a number of application examples for our multiple paths extraction algorithm.
Resumo:
Aim: To rapidly quantify hepatitis B virus (HBV) DNA by real-time PCR using efficient TaqMan probe and extraction methods of virus DNA. Methods: Three standards were prepared by cloning PCR products which targeted S, C and X region of HBV genome into pGEM-T vector respectively. A pair of primers and matched TaqMan probe were selected by comparing the copy number and the Ct values of HBV serum samples derived from the three different standard curves using certain serum DNA. Then the efficiency of six HBV DNA extraction methods including guanidinium isothiocyanate, proteinase K, NaI, NaOH lysis, alkaline lysis and simple boiling was analyzed in sample A, B and C by real-time PCR. Meanwhile, 8 clinical HBV serum samples were quantified. Results: The copy number of the same HBV serum sample originated from the standard curve of S, C and X regions was 5.7 × 104/ mL, 6.3 × 102/mL and 1.6 × 103/mL respectively. The relative Ct value was 26.6, 31.8 and 29.5 respectively. Therefore, primers and matched probe from S region were chosen for further optimization of six extraction methods. The copy number of HBV serum samples A, B and C was 3.49 × 109/mL, 2.08 × 106/mL and 4.40 × 107/mL respectively, the relative Ct value was 19.9, 30 and 26.2 in the method of NaOH lysis, which was the efficientest among six methods. Simple boiling showed a slightly lower efficiency than NaOH lysis. Guanidinium isothiocyanate, proteinase K and NaI displayed that the copy number of HBV serum sample A, B and C was around 105/ mL, meanwhile the Ct value was about 30. Alkaline failed to quantify the copy number of three HBV serum samples, Standard deviation (SD) and coefficient variation (CV) were very low in all 8 clinical HBV serum samples, showing that quantification of HBV DNA in triplicate was reliable and accurate. Conclusion: Real-time PCR based on optimized primers and TaqMan probe from S region in combination with NaOH lysis is a simple, rapid and accurate method for quantification of HBV serum DNA. © 2006 The WJG Press. All rights reserved.