983 resultados para B890 Medical Technology not elsewhere classified


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Arriving in Brisbane some six years ago, I could not help being impressed by what may be prosaically described as its atmospheric amenity resources. Perhaps this in part was due to my recent experiences in major urban centres in North America, but since that time, that sparkling quality and the blue skies seem to have progressively diminished. Unfortunately, there is also objective evidence available to suggest that this apparent deterioration is not merely the result of habituation of the senses. Air pollution data for the city show trends of increasing concentrations of those very substances that have destroyed the attractiveness of major population centres elsewhere, with climates initially as salubrious. Indeed, present figures indicate that photochemical smog in unacceptably high concentrations is rapidly becoming endemic also over Brisbane. These regrettable developments should come as no surprise. The society at large has not been inclined to respond purposefully to warnings of impending environmental problems, despite the experiences and publicity from overseas and even from other cities within Australia. Nor, up to the present, have certain politicians and government officials displayed stances beyond those necessary for the maintenance of a decorum of concern. At this stage, there still exists the possibility for meaningful government action without the embarrassment of losing political favour with the electorate. To the contrary, there is every chance that such action may be turned to advantage with increased public enlightenment. It would be more than a pity to miss perhaps the final remaining opportunity: Queensland is one of the few remaining places in the world with sufficient resources to permit both rational development and high environmental quality. The choice appears to be one of making a relatively minor investment now for a large financial and social gain the near future, or, permitting Brisbane to degenerate gradually into just another stagnated Los Angeles or Sydney. The present monograph attempts to introduce the problem by reviewing the available research on air quality in the Brisbane area. It also tries to elucidate some seemingly obvious, but so far unapplied management approaches. By necessity, such a broad treatment needs to make inroads into extensive ranges of subject areas, including political and legal practices to public perceptions, scientific measurement and statistical analysis to dynamics of air flow. Clearly, it does not pretend to be definitive in any of these fields, but it does try to emphasize those adjustable facets of the human use system of natural resources, too often neglected in favour of air pollution control technology. The crossing of disciplinary boundaries, however, needs no apology: air quality problems are ubiquitous, touching upon space, time and human interaction.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Durante las últimas tres décadas el interés y diversidad en el uso de canales escalonados han aumentado debido al desarrollo de nuevas técnicas y materiales que permiten su construcción de manera rápida y económica (Concreto compactado con rodillo CCR, Gaviones, etc.). Actualmente, los canales escalonados se usan como vertedores y/o canales para peces en presas y diques, como disipadores de energía en canales y ríos, o como aireadores en plantas de tratamiento y torrentes contaminados. Diversos investigadores han estudiado el flujo en vertedores escalonados, enfocándose en estructuras de gran pendiente (  45o) por lo que a la fecha, el comportamiento del flujo sobre vertedores con pendientes moderadas (  15 a 30o) no ha sido totalmente comprendido. El presente artículo comprende un estudio experimental de las propiedades físicas del flujo aire-agua sobre canales escalonados con pendientes moderadas, típicas en presas de materiales sueltos. Un extenso rango de gastos en condiciones de flujo rasante se investigó en dos modelos experimentales a gran escala (Le = 3 a 6): Un canal con pendiente 3.5H:1V (  16o) y dos alturas de escalón distintas (h = 0.1 y 0.05 m) y un canal con pendiente 2.5H:1V (  22o) y una altura de escalón de h = 0.1 m. Los resultados incluyen un análisis detallado de las propiedades del flujo en vertedores escalonados con pendientes moderadas y un nuevo criterio de diseño hidráulico, el cual está basado en los resultados experimentales obtenidos. English abstract: Stepped chutes have been used as hydraulic structures since antiquity, they can be found acting as spillways and fish ladders in dams and weirs, as energy dissipators in artificial channels, gutters and rivers, and as aeration enhancers in water treatment plants and polluted streams. In recent years, new construction techniques and materials (Roller Compacted Concrete RCC, rip-rap gabions, etc.) together with the development of the abovementioned new applications have allowed cheaper construction methods, increasing the interest in stepped chute design. During the last three decades, research in stepped spillways has been very active. However, studies prior to 1993 neglected the effect of free-surface aeration. A number of studies have focused since on steep stepped chutes (  45o) but the hydraulic performance of moderate-slope stepped channels is not yet totally understood. This study details an experimental investigation of physical air-water flow properties down moderate slope stepped spillways conducted in two laboratory models: the first model was a 3.15 m long stepped chute with a 15.9o slope comprising two interchangeable step heights (h = 0.1 m and h = 0.05 m); the second model was a 3.3 m long, stepped channel with a 21.8o slope (h = 0.1 m). A broad range of discharges within transition and skimming flow regimes was investigated. Measurements were conducted using a double tip conductivity probe. The study provides new, original insights into air-water stepped chute flows not foreseen in prior studies and presents a new design criterion for chutes with moderate slopes based on the experimental results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

For the last three decades, the engineering higher education and professional environments have been completely transformed by the "electronic/digital information revolution" that has included the introduction of personal computer, the development of email and world wide web, and broadband Internet connections at home. Herein the writer compares the performances of several digital tools with traditional library resources. While new specialised search engines and open access digital repositories may fill a gap between conventional search engines and traditional references, these should be not be confused with real libraries and international scientific databases that encompass textbooks and peer-reviewed scholarly works. An absence of listing in some Internet search listings, databases and repositories is not an indication of standing. Researchers, engineers and academics should remember these key differences in assessing the quality of bibliographic "research" based solely upon Internet searches.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

For centuries, hydraulic engineers were at the forefront of science. The last forty years marked a change of perception in our society with a focus on environmental sustainability and management, particularly in developed countries. Herein, the writer illustrates his strong belief that the future of hydraulic engineering lies upon a combination of innovative engineering, research excellence and higher education of quality. This drive continues a long tradition established by eminent scholars like Arthur Thomas IPPEN, John Fisher KENNEDY and Hunter ROUSE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Erluanbi is the most southern tip of Taiwan (Formosa) where the Taiwan (Formosa) Strait meets the Pacific Ocean. The Erluanbi national park is renown for its lighthouse, and its coral reef, and it hosts also some prehistoric sites bating back to 5,000 to 6,500 years. The Erluanbi (or Eluan Pi) lighthouse was completed in 1883, following requests from the American and Japanese governments to the Chinese government after several ship wrecks in the 1860s. Chinese troops were sent to protect the lighthouse construction from attacks by local tribesmen, and the lighthouse was surrounded a small fort with cannons and a ditch to protect it. It is a rare example of a fortified lighthouse in the world. The lighthouse itself is 21.4 m high and its light is 56.4 m above high water. The light flashes every 10 seconds and its range is 27.2 nautical miles. The surrounding Erluanbi national park is located on a raised coral reef with some huge fringing reef : e.g., the "sea pavillon". With the topical oceanic climate, the elevated reef hosts an unique vegetation and ecology. Since 1956, numerous prehistoric artefacts were uncovered including stone slab coffins and pottery (plain and painted), that encompassed at least four cultural stages from BC 4,500 to AD 800.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To the Editor: The increase in medical graduates expected over the next decade presents a huge challenge to the many stakeholders involved in providing their prevocational and vocational medical training. 1 Increased numbers will add significantly to the teaching and supervision workload for registrars and consultants, while specialist training and access to advanced training positions may be compromised. However, this predicament may also provide opportunities for innovation in the way internships are delivered. Although facing these same challenges, regional and rural hospitals could use this situation to enhance their workforce by creating opportunities for interns and junior doctors to acquire valuable experience in non-metropolitan settings. We surveyed a representative sample (n = 147; 52% of total cohort) of Year 3 Bachelor of Medicine and Bachelor of Surgery students at the University of Queensland about their perceptions and expectations of their impending internship and the importance of its location (ie, urban/metropolitan versus regional/rural teaching hospitals) to their future training and career plans. Most students (n = 127; 86%) reported a high degree of contemplation about their internship choice. Issues relating to career progression and support ranked highest in their expectations. Most perceived internships in urban/metropolitan hospitals as more beneficial to their future career prospects compared with regional/rural hospitals, but, interestingly, felt that they would have more patient responsibility and greater contact with and supervision by senior staff in a regional setting (Box). Regional and rural hospitals should try to harness these positive perceptions and act to address any real or perceived shortcomings in order to enhance their future workforce.2 They could look to establish partnerships with rural clinical schools3 to enhance recruitment of interns as early as Year 3. To maximise competitiveness with their urban counterparts, regional and rural hospitals need to offer innovative training and career progression pathways to junior doctors, to combat the perception that internships in urban hospitals are more beneficial to future career prospects. Partnerships between hospitals, medical schools and vocational colleges, with input from postgraduate medical councils, should provide vertical integration4 in the important period between student and doctor. Work is underway to more closely evaluate and compare the intern experience across regional/rural and urban/metropolitan hospitals, and track student experiences and career choices longitudinally. This information may benefit teaching hospitals and help identify the optimal combination of resources necessary to provide quality teaching and a clear career pathway for the expected influx of new interns.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A novel three-axis gradient set and RF resonator for orthopedic MRT has been designed and constructed. The set is openable and may be wrapped around injured joints. The design methodology used was the minimization of magnetic field spherical harmonics by simulated annealing. Splitting of the longitudinal coil presents the major design challenge to a fully openable gradient set and in order to efficiently design such coils, we have developed a new fast algorithm for determining the magnetic field spherical harmonics generated by an are of multiturn wire. The algorithm allows a realistic impression of the effect of split longitudinal designs. A prototype set was constructed based on the new designs and tested in a 2-T clinical research system. The set generated 12 mT/m/A with a linear region of 12 cm and a switching time of 100 mu s, conforming closely with theoretical predictions. Preliminary images from the set are presented. (C) 1999 Academic Press.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Solieria, the type genus of the commercially important red algal family Solieriaceae (Gigartinales), contains seven or eight species, three of which are represented in Australia. The cell-wall galactans of the most common Australian Solieria species, S. robusta (Greville) Kylin, were analysed by a combination of compositional assays, linkage analysis, and Fourier transform infrared (FTIR) and C-13 nuclear magnetic resonance (NMR) spectroscopy. They are shown to be composed predominantly of carrabiose 2,4'-disulphate units (the repeating unit of iota-carrageenan) and a significant proportion of 4',6'-pyruvated carrabiose 2-sulphate units. The constituent sugars, pyruvate content, FTIR spectrum, and linkage and substitution patterns of the galactans from Tikvahiella candida Kraft et Gabrielson, an adelphoparasite of Solieria robusta, closely resemble those of its host and furnish evidence in support of a close phylogenetic relationship between the two species.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Imaging of the head and neck is the most commonly performed clinical magnetic resonance imaging (MRI) examination [R. G. Evans and J. R. G. Evans, AJR 157, 603 (1991)]. This is usually undertaken in a generalist MRI instrument containing superconducting magnet system capable of imaging all organs. These generalist instruments are large, typically having a bore of 0.9-1.0 m and a length of 1.7-2.5 m and therefore are expensive to site, somewhat claustrophobic to the patient, and offer little access by attending physicians. In this article, we present the design of a compact, superconducting MRI magnet for head and neck imaging that is less than 0.8 m in length and discuss in detail the design of an asymmetric gradient coil set, tailored to the magnet profile. In particular, the introduction of a radio-frequency FM modulation scheme in concert with a gradient sequence allows the epoch of the linear region of the gradient set to be much closer to the end of the gradient structure than was previously possible. Images from a prototype gradient set demonstrate the effectiveness of the designs. (C) 1999 American Institute of Physics. [S0034-6748(99)04910-2].

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper describes a hybrid numerical method for the design of asymmetric magnetic resonance imaging magnet systems. The problem is formulated as a field synthesis and the desired current density on the surface of a cylinder is first calculated by solving a Fredholm equation of the first kind. Nonlinear optimization methods are then invoked to fit practical magnet coils to the desired current density. The field calculations are performed using a semi-analytical method. A new type of asymmetric magnet is proposed in this work. The asymmetric MRI magnet allows the diameter spherical imaging volume to be positioned close to one end of the magnet. The main advantages of making the magnet asymmetric include the potential to reduce the perception of claustrophobia for the patient, better access to the patient by attending physicians, and the potential for reduced peripheral nerve stimulation due to the gradient coil configuration. The results highlight that the method can be used to obtain an asymmetric MRI magnet structure and a very homogeneous magnetic field over the central imaging volume in clinical systems of approximately 1.2 m in length. Unshielded designs are the focus of this work. This method is flexible and may be applied to magnets of other geometries. (C) 1999 Academic Press.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Two alpha-conotoxins PnIA and PnIB (previously reported as being mollusc specific) which differ in only two amino acid residues (AN versus LS at residues 10 and 11, respectively), show markedly different inhibition of the neuronal nicotinic acetylcholine receptor response in bovine chromaffin cells, a mammalian preparation. Whereas alpha-conotoxin PnIB completely inhibits the nicotine-evoked catecholamine release at 10 mu M, with IC50 = 0.7 mu M, alpha-conotoxin PnIA is some 30-40 times less potent. Two peptide analogues, [A10L]PnIA and [N11S]PnIA were synthesized to investigate the extent to which each residue contributes to activity. [A10L]PnIA (IC50 = 2.0 mu M) completely inhibits catecholamine release at 10 mu M whereas [N11S]PnIA shows Little inhibition. In contrast, none of the peptides inhibit muscle-type nicotinic responses in the rat hemi-diaphragm preparation. We conclude that the enhanced potency of alpha-conotoxin PnIB over alpha-conotoxin PnIA in the neuronal-type nicotinic response is principally determined by the larger, more hydrophobic leucine residue at position 10 in alpha-conotoxin PnIB. (C) 2000 Elsevier Science B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper describes a hybrid numerical method of an inverse approach to the design of compact magnetic resonance imaging magnets. The problem is formulated as a field synthesis and the desired current density on the surface of a cylinder is first calculated by solving a Fredholm equation of the first, kind. Nonlinear optimization methods are then invoked to fit practical magnet coils to the desired current density. The field calculations are performed using a semi-analytical method. The emphasis of this work is on the optimal design of short MRI magnets. Details of the hybrid numerical model are presented, and the model is used to investigate compact, symmetric MRI magnets as well as asymmetric magnets. The results highlight that the method can be used to obtain a compact MRI magnet structure and a very homogeneous magnetic field over the central imaging volume in clinical systems of approximately 1 m in length, significantly shorter than current designs. Viable asymmetric magnet designs, in which the edge of the homogeneous region is very close to one end of the magnet system are also presented. Unshielded designs are the focus of this work. This method is flexible and may be applied to magnets of other geometries. (C) 2000 American Association of Physicists in Medicine. [S0094-2405(00)00303-5].