80 resultados para liquid smoking
Resumo:
The authors describe a reverse-phase high-performance liquid chromatography-electrospray-tandem mass spectrometry method for the measurement of nicotine in human plasma. Samples (500 muL) with added deuterium-labeled d(3)-nicotine as an internal standard (IS) were treated with a 2-step process of ether extraction (6 mL) followed by back-extraction into 0.1% formic acid (50 muL). Chromatography was performed on a phenyl Novapak column with a mobile phase consisting of 50% 10 mM ammonium fortriate (pH 3.3) and acetonitrile (50:50, vol/vol). A flow rate of 0.2 mL/min resulted in a total analysis time of 5 minutes per sample. Mass spectrometric detection was by selected reactant monitoring (nicotine m/z 163.2 --> 130.2; IS m/z 166.2 --> 87.2). The assay was linear from 0.5 to 100 mug/L (r > 0.993, n = 9). The accuracy and imprecision of the method for quality control sampleswere 87.5% to 113% and < 10.2%, respectively. Interday accuracy and imprecision at the limit of quantification (0.5 mug/L) was 113% and 7.2% (n = 4). The process efficiency for nicotine in plasma was > 75%. The method described has good process efficiency, stabilized nicotine, avoided concentration steps, and most importantly minimized potential contamination. Further, we have established that water-based standards and controls are interchangeable with plasma-based samples. This method was used successfully to measure the pharmacokinetic profiles of subjects involved in the development of an aerosol inhalation drug delivery system.
Resumo:
Context Smoking is a major preventable cause of death and disability that is maintained by dependence on nicotine. Smoking cessation reduces mortality and morbidity. Although existing pharmacological aids to smoking cessation and relapse prevention (nicotine replacement therapy and bupropion) improve on unassisted quitting and behavioural methods, they are only modestly effective. More effective pharmacological methods are required that improve compliance, reduce side-effects, and can be used in combination with existing cessation methods. Starting point A nicotine vaccine is a promising immunotherapeutic approach to smoking cessation and relapse prevention. Such a vaccine would induce the immune system to form specific antibodies to nicotine to prevent it from crossing the blood-brain barrier to act on receptor sites in the central nervous system. Recent studies in rats provide proof of principle by showing that nicotine-specific antibodies can prevent the reinstatement of nicotine self-administration (N Lindblom et al, Respiration 2002; 69: 254–60) and block dopamine release in the shell of the nucleus accumbens (Sde Villiers et al, Respiration 2002; 69: 247–53). A phase 1 trial of a human cocaine vaccine has also recently been successfully completed (T Kosten et al, Vaccine 2002; 20: 1196–204). A safe and effective human nicotine vaccine would potentially have fewer side-effects and better compliance than existing smoking-cessation pharmacotherapies. It could also be used in combination with some of them (eg, bupropion). Where next? The most promising clinical application of a human nicotine vaccine is likely to be in relapse prevention in abstinent smokers. A vaccine may also have a role in preparing smokers to quit. Clinical trials of safety and efficacy in human smokers and ex-smokers are warranted. If a nicotine vaccine proves to be safe and effective, the health-care system will need to ensure that it is registered for clinical use and that the poorer members of the community (among whom smoking prevalence is now highest in developed countries) have access to the vaccine. The community will need to be appropriately informed about the role of a nicotine vaccine to ensure that it is not prematurely used for preventive purposes in children and adolescents.
Resumo:
This is the first report of an inverse relationship between passive smoking exposure and Parkinson's disease.
Resumo:
Copper concentrate (chalcopyrite) was granulated in a rotating drum with a diameter of 0.3 m and a length of 0.2 m. Water was used as the binder and it was sprayed onto the powder bed with a nozzle. This material exhibited induction type behaviour, which was defined by Iveson and Litster [AIChE J. 44 (1998) 1510]. Induction type behaviour is characterized by the occurrence of an induction stage, during which the granules are gradually being compacted and little or no growth occurs. At the end of this induction stage, binder liquid is squeezed from the interior of the granules onto the granule surface and the granules are then surface-wet. This results in a rapid growth rate of the granules. Different types of experiments were conducted. The influence of the nozzle pressure and the distance from the nozzle to the powder bed on the growth behaviour of the granules as well as on the binder distribution was examined. The results of these experiments led to the postulation of a modified mechanism for induction type behaviour: it was found that after the binder was delivered, there were large granules containing a high amount of binder and small granules containing less binder. During the induction stage, the granules are compacted and binder liquid continuously appears at the surface of the large granules. These wet spots that are continuously being formed pick up the dry and small granules. When all the small granules have been picked up, further expulsion of binder liquid onto the granules' surface results in granules that remain surface-wet. This phenomenon marks the end of the induction stage and it coincides with the disappearance of the small granules. The hypothesis was tested by selectively removing the smaller granules during an experiment. As expected, this resulted in a shorter induction time.
Resumo:
An exact analytical solution is obtained for the transient dissolution of solid spheres in a diffusion-controlled environment. This result provides a useful reference point for drug testing in humans. The dimensionless solution is expressed in terms of a single parameter, which accounts for solubility, bulk flow, and stagnant fluid composition. A simple, explicit and exact expression was found to predict time-to-complete dissolution (TCD). An approximate solution was also found which tracks the exact case for low solubility conditions.
Resumo:
This communication describes an improved one-step solid-phase extraction method for the recovery of morphine (M), morphine-3-glucuronide (M3G), and morphine-6-glucuronide (M6G) from human plasma with reduced coextraction of endogenous plasma constituents, compared to that of the authors' previously reported method. The magnitude of the peak caused by endogenous plasma components in the chromatogram that eluted immediately before the retention time of M3G has been reduced (similar to 80%) significantly (p < 0.01) while achieving high extraction efficiencies for the compounds of interest, viz morphine, M6G, and M3G (93.8 +/- 2.5, 91.7 +/- 1.7, and 93.1 +/- 2.2%, respectively). Furthermore, when the improved solid-phase extraction method was used, the extraction cartridge-derived late-eluting peak (retention time 90 to 100 minutes) reported in our previous method, was no longer present in the plasma extracts. Therefore the combined effect of reducing the recovery of the endogenous components of plasma that chromatographed just before the retention time of M3G and the removal of the late-eluting, extraction cartridge-derived peak has resulted in a decrease in the chromatographic run-time to 20 minutes, thereby increasing the sample throughput by up to 100%.
Resumo:
A sensitive and reproducible solid-phase extraction (SPE) method for the quantification of oxycodone in human plasma was developed. Varian Certify SPE cartridges containing both C-8 and benzoic acid functional groups were the most suitable for the extraction of oxycodone and codeine (internal standard), with consistently high (greater than or equal to 80%) and reproducible recoveries. The elution mobile phase consisted of 1.2 ml of butyl chloride-isopropanol (80:20, v/v) containing 2% ammonia. The quantification limit for oxycodone was 5.3 pmol on-column. Within-day and inter-day coefficients of variation were 1.2% and 6.8% respectively for 284 nM oxycodone and 9.5% and 6.2% respectively for 28.4 nM oxycodone using 0.5-ml plasma aliquots. (C) 1998 Elsevier Science BN. All rights reserved.
Resumo:
A simple method for the measurement of pindolol enantiomers by HPLC is presented. Alkalinized serum or urine is extracted with ethyl acetate and the residue remaining after evaporation of the organic layer is then derivatised with (S)-(-)-alpha-methylbenzyl isocyanate. The diastereoisomers of derivatised pindolol and metoprolol (internal standard) are separated by high-performance liquid chromatography (HPLC) using a C-18 silica column and detected using fluorescence (excitation lambda: 215 nm, emission lambda: 320 nm). The assay displays reproducible linearity for pindolol enantiomers with a correlation coefficient of r(2) greater than or equal to 0.998 over the concentration range 8-100 ng ml(-1) for plasma and 0.1-2.5 mu g ml(-1) for urine. The coefficient of variation for accuracy and precision of the quality control samples for both plasma and urine are consistently
Resumo:
Cannabis users have recently been told that cannabis smoking is ª relatively harmlessº 1 and presents ª minimal danger to the lungsº .2 These statements seem at odds with the similarities between the carcinogens and other toxic constituents in tobacco and cannabis smoke, the fact that un® ltered cannabis smoke contains more of some carcinogens than ® ltered tobacco smoke3,4 and other evidence that chronic cannabis smoking has adverse respiratory effects.5
Resumo:
Mycophenolic acid is an immunosuppressant administered as a bioavailable ester, mycophenolate mofetil. The pharmacokinetics of mycophenolic acid have been reported to be variable. Accurate measurement of concentrations of this drug could be important to adjust doses. The aim of this study was to compare the enzyme-multiplied immunoassay technique (EMIT [Dade Behring; San Jose, CA, U.S.A.]) for mycophenolic acid with a high-performance liquid chromatographic (HPLC) assay using samples collected from renal transplant recipients. The HPLC assay used solid phase extraction and a C18 stationary phase with ultraviolet (UV) detection (254 nm). The immunoassay required no manual sample preparation. Plasma samples (n = 102) from seven patients, collected at various times after a dose, were analyzed using both methods. Both assays fulfilled quality-control criteria. Higher concentrations were consistently measured in patient samples when using EMIT. The mean (+/- standard deviation [SD]) bias (EMIT-HPLC) was 1.88 +/- 0.86 mg/L. The differences in concentrations were higher in the middle of a dosage interval, suggesting that a metabolite might have been responsible for overestimation. Measurement of glucuronide concentrations by HPLC demonstrated only a weak correlation between assay differences and glucuronide concentrations. If the crossreacting substance is active, EMIT could provide a superior measure of immunosuppression; if inactive, further work is needed to improve antibody specificity. In conclusion, it was found that EMIT overestimates the concentration of mycophenolic acid in plasma samples from renal transplant recipients compared with HPLC analysis.
Resumo:
A sensitive high-performance liquid chromatographic assay has been developed for measuring plasma concentrations of methotrexate and its major metabolite, 7-hydroxymethotrexate. Methotrexate and metabolite were extracted from plasma using solid-phase extraction. An internal standard, aminopterin was used. Chromatographic separation was achieved using a 15-cm poly(styrene-divinylbenzene) (PRP-1(R)) column. This column is more robust than a silica-based stationary phase. Post column, the eluent was irradiated with UV light, producing fluorescent photolytic degradation products of methotrexate and the metabolite. The excitation and emission wavelengths of fluorescence detection were at 350 and 435 nm, respectively. The mobile phase consisted of 0.1 M phosphate buffer (pH 6.5), with 6% N,N-dimethylformamide and 0.2% of 30% hydrogen peroxide. The absolute recoveries for methotrexate and 7-hydroxymethotrexate were greater than 86%. Precision, expressed as a coefficient of variation (n=6), was
Resumo:
Objective-To examine changes in the prevalence of cigarette smoking in 35 study populations of the World Health Organisation's MONICA Project. Design-Data from two independent, community-based surveys conducted, on average, five years apart. Setting-Geographically defined populations in 21 countries mainly in eastern and western Europe. Subjects-Randomly selected men and women aged 25-64 years. Numbers of participants in each study population ranged from 586 to 2817 in each survey. Main outcome measures-Changes in proportions of current smokers, ex-smokers, and never-smokers by age and sex using data collected by standardised methods. Results-Among men, smoking prevalence decreased in most populations, by three to four percentage points over five years. In Beijing, however, it increased in all age groups-overall by 11 percentage points. Among women there were increases in smoking in about half the populations. The increases were mainly in the age group 35-54 years and often in those populations where smoking prevalence among women has been relatively low. Conclusions-Smoking initiation by middle-aged women in parts of southern and eastern Europe and among men of all ages in Beijing is a matter of concern. The various public health measures that have helped to reduce smoking among men in developed countries should be vigorously extended to these other groups now at growing risk of smoking-related disease.
Resumo:
The objective of this study was to determine the rate of the decline in risk of a major coronary event after quitting cigarette smoking. It was a population-based case-control study of men and women aged 35 to 69 years in Newcastle, Australia, and men and women aged 35 to 64 years in Auckland, New Zealand, between 1986 and 1994. Cases were 5,572 people identified in population registers of coronary events and controls were 6,268 participants in independent community-based risk factor prevalence surveys from the same study populations. There was a rapid reduction in risk after quitting cigarette smoking. The risk of suffering a major coronary event for men who were current cigarette smokers was 3.5 (95% CI 3.0-4.0) times higher than the risk for never smokers but this fell to 1.5 (95% CI 1.1-1.9) for men who had quit for 1-3 years. Women who were current cigarette smokers were 4.8 (95% CI 4.0-5.9) times more likely to suffer a major coronary event than never smokers and this fell to 1.6 (95% CI 1.0-2.5) for women who had quit for 1-3 years. Those who had quit cigarette smoking for 4-6 years or more had a similar risk to never smokers. These results reinforce the importance of smoking cessation. The public health message is that the benefit of giving up smoking occurs rapidly.