211 resultados para TISSUE DOPPLER IMAGING
Resumo:
Purpose of review Heart failure and diabetes mellitus are frequently associated, and diabetes appears to potentiate the clinical presentation of heart failure related to other causes. The purpose of this review is to examine recent advances in the application of tissue Doppler imaging for the assessment of diabetic heart disease. Recent findings Recent studies have documented that both myocardial systolic and diastolic abnormalities can be identified in apparently healthy patients with diabetes and no overt cardiac dysfunction. Interestingly, these are disturbances of longitudinal function, with compensatory increases of radial function-suggesting primary involvement of the subendocardium, which is a hallmark of myocardial ischemia. Despite this, there is limited evidence that diabetic microangiopathy is responsible-with reduced myocardial blood volume rather than reduced resting flow, and at least some evidence suggesting a normal increment of tissue velocity with stress. Finally, a few correlative studies have shown association of diabetic myocardial disease with poor glycemic control, while angiotensin converting enzyme inhibition may be protective. Summary Tissue Doppler imaging (and the related technique of strain rate imaging) appears to be extremely effective for the identification of subclinical LV dysfunction in diabetic patients It is hoped that the recognition of this condition will prompt specific therapy to prevent the development of overt LV dysfunction.
Resumo:
The extent of abnormality in patients with positive do-butamine echocardiography (DE) is predictive of risk, but the wall motion score (WMS) has low concordance among observers. We sought whether quantifying the extent of abnormal wall motion using tissue Doppler (TD) could guide risk assessment in patients with abnormal DE in 576 patients with known or suspected coronary artery disease; standard DE was combined with color TD imaging at peak dose. WMS was assessed by an expert observer and studies were identified as abnormal in the presence of 2:1 segments with resting or stress-induced wall motion abnormalities. Patients with abnormal DE had peak systolic velocity measured in each segment. Tissue tracking was used to measure myocardial displacement. Follow-up for death or infarction was per-formed after. 16 +/- 12 months. Of 251 patients with abnormal DE, 22 patients died (20 from cardiac causes) and 7 had nonfatal myocardial infarctionis. The average WMS in patients with events was 1.8 +/- 0.5, compared with 1.7 +/- 0.5 in patients without events (p = NS). The average systolic velocity in patients with events was 4.9 +/- 1.7 cm/s and 6.4 +/- 6.5 cm/s in the patients without events (p <0.001). The average tissue tracking in patients with events was 4.5 +/- 1.5 mm and was significant. (5.7 +/- 3.1 mm),in those,without events (p <0.001). Thus, TD is an alternative to WMS for quantifying the total extent of abnormal left ventricular function-at DE, and appears to be superior for predicting adverse outcomes. (C) 2004 by Excerpta Medica, Inc.
Resumo:
Biventdcular (BV) pacing is evaluated as an alternative treatment for patients with dilated cardiomyppathy (both ischemic and non-ischemic) and end-stage heart failure. Colour tissue Doppler imaging using echocardiography allows noninvasive, quantitative assessment of radial motion in the long-axis with measurement of peak systolic velocity timing. The aim of the present study was to evaluate quantitatively, the systolic performance of the left ventricle and the resynchrenization of contraction (before vs after implantation). Patients and methods: 25 patients with dilated cardiomyopathy (11 ischemic), NYHA class III or IV, QRS duration >120 ms received a biventricular pacemaker. Routine 2D echo and colour tissue Doppler imaging were performed before and within 1 week following implantation. LVEF was assessed using the biplane Sampson's method.Peak systolic velocity (PSV) and time to PSV (TPV) were assessed in 4 regions (basal anterior, inferior, lateral and septal). By averaging the TPV from all 4 regions, a synchronization index was dedved from these measurements. Reaults: LVEF improved by 9±9% following pacing; 17 patients improved LVEF 5% or more. The change in PSV in the septal and lateral regions related significantly to the change in LVEF (r=0.74, r=0.62).The change in synchronization index before vs after pacing (as a measurement of REsynchronization) was related to the change in LVEF (y=120x+5.6, r=0.79, P
Resumo:
Tissue Doppler imaging allows assessment of left ventricular dyssynchrony and resynchronization after biventricular pacing.
Resumo:
Background. Exercise therapy improves functional capacity in CHF, but selection and individualization of training would be helped by a simple non-invasive marker of peak VO2. Peak VO2 in these pts is difficult to predict without direct measurement, and LV ejection fraction is a poor predictor. Myocardial tissue velocities are less load-dependent, and may be predictive of the exercise response in CHF pts. We sought to use tissue velocity as a predictor of peak VO2 in CHF pts. Methods. Resting 2D-echocardiography and tissue Doppler imaging were performed in 182 CHF pts (159 male, age 62±10 years) before and after metabolic exercise testing. The majority of these patients (129, 71%) had an ischemic cardiomyopathy, with resting EF of 35±13% and a peak VO2 of 13.5±4.7 ml/kg/min. Results. Neither resting EF (r=0.15) nor peak EF (r=0.18, both p=NS) were correlated with peak VO2. However, peak VO2 correlated with peak systolic velocity in septal (Vss, r=0.31) and lateral walls (Vsl, r=0.26, both p=0.01). In a general linear model (r2 = 0.25), peak VO2 was calculated from the following equation: 9.6 + 0.68*Vss - 0.09*age + 0.06*maximum HR. This model proved to be a superior predictor of peak VO2 (r=0.51, p=0.01) than the standard prediction equations of Wasserman (r= -0.12, p=0.01). Conclusions. Resting tissue Doppler, age and maximum heart rate may be used to predict functional capacity in CHF patients. This may be of use in selecting and following the response to therapy, including for exercise training.
Resumo:
Purpose: Tissue Doppler strain rate imaging (SRI) have been validated and applied in various clinical settings, but the clinical use of this modality is still limited due to time-consuming postprocessing, unfavorable signal to noise ratio and major angle dependency of image acquisition. 2D Strain (2DS) measures strain parameters through automated tissue tracking (Lagrangian strain) rather than tissue velocity regression. We sought to compare the accuracy of this technique with SRI and evaluate whether it overcomes the above limitations. Methods: We assessed 26 patients (13 female, age 60±5yrs) at low risk of CAD and with normal DSE at both baseline and peak stress. End systolic strain (ESS), peak systolic strain rate (SR), and timing parameters were measured by two independent observers using SRI and 2D Strain. Myocardial segments were excluded from the analyses if the insonation angle exceeded 30 degrees or if the segments were not visualized; 417 segments were evaluated. Results: Normal ranges for TVI and CEB approaches were comparable for SR (-0.99 ± 0.39 vs -0.88 ± 0.36, p=NS), ESS (-15.1 ± 6.5 vs -14.9 ± 6.3, p=NS), time to end of systole (174 ± 47 vs 174 ± 53, p=NS) and time to peak SR (TTP; 340 ± 34 vs 375 ± 57). The best correlations between the techniques were for time to end systole (rest r=0.6, p
Resumo:
The subjective interpretation of dobutamine echocardiography (DBE) makes the accuracy of this technique dependent on the experience of the observer, and also poses problems of concordance between observers. Myocardial tissue Doppler velocity (MDV) may offer a quantitative technique for identification of coronary artery disease, but it is unclear whether this parameter could improve the results of less expert readers and in segments with low interobserver concordance. The aim of this study was to find whether MDV improved the accuracy of wall motion scoring in novice readers, experienced echocardiographers, and experts in stress echocardiography, and to identify the optimal means of integrating these tissue Doppler data in 77 patients who underwent DBE and angiography. New or worsening abnormalities were identified as ischemia and abnormalities seen at rest as scarring. Segmental MDV was measured independently and previously derived cutoffs were applied to categorize segments as normal or ab normal. Five strategies were used to combine MDV and wall motion score, and the results of each reader using each strategy were compared with quantitative coronary angiography. The accuracy of wall motion scoring by novice (68 +/- 3%) and experienced echocardiographers (71 +/- 3%) was less than experts in stress echocardiography (88 +/- 3%, p < 0.001). Various strategies for integration with MDV significantly improved the accuracy of wall motion scoring by novices from 75 +/- 2% to 77 +/- 5% (p < 0.01). Among the experienced group, accuracy improved from 74 +/- 2% to 77 +/- 5% (p < 0.05), but in the experts, no improvement was seen from their baseline accuracy. Integration with MDV also improved discordance related to the basal segments. Thus, use of MDV in all segments or MDV in all segments with wall motion scoring in the apex offers an improvement in sensitivity and accuracy with minimal compromise in specificity. (C) 2001 by Excerpta Medica, Inc.
Resumo:
Background Diastolic dysfunction induced by ischemia may alter transmitral blood flow, but this reflects global ventricular function, and pseudonormalization may occur with increased preload. Tissue Doppler may assess regional diastolic function and is relatively load-independent, but limited data exist regarding its application to stress testing. We sought to examine the stress response of regional diastolic parameters to dobutomine echocardiography (DbE). Methods Sixty-three patients underwent study with DbE: 20 with low probability of coronary artery disease (CAD) and 43 with CAD who underwent angiography. A standard DbE protocol was used, and segments were categorized as ischemic, scar, or normal. Color tissue Doppler was acquired at baseline and peak stress, and waveforms in the basal and mid segments were used to measure early filling (Em), late filling (Am), and E deceleration time. Significant CAD was defined by stenoses >50% vessel diameter. Results Diastolic parameters had limited feasibility because of merging of Em and Am waves at high heart rates and limited reproducibility. Nonetheless, compared with normal segments, segments subtended with significant stenoses showed a lower Em velocity at rest (6.2 +/- 2.6 cm/s vs 4.8 +/- 2.2 cm/s, P < .0001) and peak (7.5 +/- 4.2 cm/s vs 5.1 +/- 3.6 cm/s, P < .0001), Abnormal segments also showed a shorter E deceleration time (51 +/- 27 ms vs 41 +/- 27 ms, P = .0001) at base and peak. No changes were documented in Am. The same pattern was seen with segments identified as ischemic with wall motion score. However, in the absence of ischemia, segments of patients with left ventricular hypertrophy showed a lower Em velocity, with blunted Em responses to stress. Conclusion Regional diastolic function is sensitive to ischemia. However, a number of practical limitations limit the applicability of diastolic parameters for the quantification of stress echocardiography.
Resumo:
Abnormal left ventricular (LV) filling is common, but not universal, in hypertensive LV hypertrophy (LVH). We sought to elucidate the relative contributions of myocardial structural changes, loading and hypertrophy to LV dysfunction in 113 patients: 85 with hypertensive LVH and 28 controls without LVH and with normal filling. Patients with normal dobutamine stress echocardiography and no history of coronary artery disease were selected, in order to exclude a contribution from ischaemia or scar. Abnormal LV filling was identified in 65 LVH patients, based on Doppler measurement of transmitral filling and annular velocities. All patients underwent grey-scale and colour tissue Doppler imaging from three apical views, which were stored and analysed off line. Integrated backscatter (113) and strain rate imaging were used to detect changes in structure and function; average cyclic variation of 113, strain rate and peak systolic strain were calculated by averaging each segment. Calibrated 113 intensity, corrected for pericardial 113 intensity, was measured in the septum and posterior wall from the parasternal long-axis view. Patients with LVH differed significantly from controls with respect to all backscatter and strain parameters, irrespective of the presence or absence of abnormal LV filling. LVH patients with and without abnormal LV filling differed with regard to age, LV mass and incidence of diabetes mellitus, but also showed significant differences in cyclic variation (P < 0.01), calibrated 113 in the posterior wall (P < 0.05) and strain rate (P < 0.01), although blood pressure, heart rate and LV systolic function were similar. Multivariate logistic regression analysis demonstrated that age, LV mass index and calibrated IB in the posterior wall were independent determinants of abnormal LV filling in patients with LVH. Thus structural and functional abnormalities can be detected in hypertensive patients with LVH with and without abnormal LV filling. In addition to age and LVH, structural (not functional) abnormalities are likely to contribute to abnormal LV filling, and may be an early sign of LV damage. 113 is useful for the detection of myocardial abnormalities in patients with hypertensive LVH.