42 resultados para Medical laboratory technology


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Hydroxychloroquine (HCQ) is an antimalarial drug that is also used as a second-line treatment of rheumatoid arthritis (RA). Clinically, the use of HCQ is characterized by a long delay in the onset of action, and withdrawal of treatment is often a result of inefficacy rather than from toxicity. The slow onset of action can be attributed to the pharmacokinetics (PK) of HCQ, and wide interpatient variability is evident. Tentative relationships between concentration and effect have been made, but to date, no population PK model has been developed for HCQ. This study aimed to develop a population PK model including an estimation of the oral bioavailability of HCQ. In addition, the effects of the coadministration of methotrexate on the PK of HCQ were examined. Hydroxychloroquine blood concentration data were combined from previous pharmacokinetic studies in patients with rheumatoid arthritis. A total of 123 patients were studied, giving the data cohort from four previously published studies. Two groups of patients were included: 74 received hydroxychloroquine (HCQ) alone, and 49 received HCQ and methotrexate (MTX). All data analyses were carried out using the NONMEM program. A one-compartment PK model was supported, rather than a three-compartment model as previously published, probably because of the clustering of concentrations taken at the end of a dosing interval. The population estimate of bioavailability of 0.75 (0.07), n = 9, was consistent with literature values. The parameter values from the final model were: (Cl) over bar = 9.9 +/- 0.4 L/h, (V) over bar 605 +/- 91 L, (k(d)) over bar = 0.77 +/- 0.22 hours(-1), (t(tag)) over bar = 0.44 +/- 0.02 hours. Clearance was not affected by the presence of MTX, and, hence, steady-state drug concentrations and maintenance dosage requirements were similar. A population PK model was successfully developed for HCQ.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A retrospective review was undertaken in 744 patients who were dose-individualized with gentamicin once daily to evaluate a change in gentamicin clearance as a potential predictor of nephrotoxicity. The definition of nephrotoxicity was chosen to be a change in creatinine clearance greater than 20%. Similarly, a change in gentamicin clearance of greater than 20% was also considered a possible index of nephrotoxicity. Four criteria were developed to assess the usefulness of gentamicin clearance as a predictor of nephrotoxicity. Following the application of the inclusion/exclusion criteria, 132 patients were available for the analysis. The sensitivity, specificity, positive predictive value, and negative predictive value were assessed for each of the criteria. Receiver operating characteristic (ROC) curves were produced to determine if an optimum value in the change of gentamicin clearance could be found to maximize sensitivity and specificity. The overall incidence of nephrotoxicity based on a decrease in creatinine clearance by 20% or more was 3.8%. Women were overrepresented in the nephrotoxic group [71.4% versus 40.1% (P = 0.0025)]. Patients with nephrotoxicity had statistically longer treatment periods, increased cumulative dose, and more dosing predictions (P < 0.05 in each case). The sensitivity of the criteria ranged from 43 to 46%, and specificity ranged from 93 to 99%. The positive and negative predictive values ranged from 63 to 94% and 86 to 89%, respectively. In those patients in whom nephrotoxicity was predicted from a change in gentamicin clearance, this change occurred on average 3 days before the change in creatinine clearance (P < 0.05). A change in gentamicin clearance to predict nephrotoxicity may be a useful addition to current monitoring methods, although it is not the complete answer.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: A new immunoassay for free light chain measurements has been reported to be useful for the diagnosis and monitoring of monoclonal light chain diseases and nonsecretory myeloma. We describe experience with and some potential pitfalls of the assay. Methods: The assay was assessed for precision, sample type and stability, recovery, and harmonization of results between two analyzers on which the reagents are used. Free-light-chain concentrations were measured in healthy individuals (to determine biological variation), patients with monoclonal gammopathy of undetermined significance, myeloma patients after autologous stem cell transplants, and patients with renal disease. Results: Analytical imprecision (CV) was 6-11% for kappa and A free-light-chain measurement and 16% for the calculated kappa/lambda ratio. Biological variation was generally insignificant compared with analytical variation. Despite the same reagent source, values were not completely harmonized between assay systems and may produce discordant free-light-chain ratios. In some patients with clinically stable myeloma, or post transplantation, or with monoclonal gammopathy of undetermined significance, free-light-chain concentration and ratio were within the population reference interval despite the presence of monoclonal intact immunoglobulin in serum. In other patients with monoclonal gammopathy of undetermined significance, values were abnormal although there was no clinical evidence of progression to multiple myeloma. Conclusions: The use of free-light-chain measurements alone cannot differentiate some groups of patients with monoclonal gammopathy from healthy individuals. As with the introduction of any new test, it is essential that more scientific data about use of this assay in different subject groups are available so that results can be interpreted with clinical certainty. (C) 2003 American Association for Clinical Chemistry.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The quality of reporting of studies of diagnostic accuracy is less than optimal. Complete and accurate reporting is necessary to enable readers to assess the potential for bias in the study and to evaluate the generalisability of the results. A group of scientists and editors has developed the STARD (Standards for Reporting of Diagnostic Accuracy) statement to improve the reporting the quality of reporting of studies of diagnostic accuracy. The statement consists of a checklist of 25 items and flow diagram that authors can use to ensure that all relevant information is present. This explanatory document aims to facilitate the use, understanding and dissemination of the checklist. The document contains a clarification of the meaning, rationale and optimal use of each item on the checklist, as well as a short summary of the available evidence on bias and applicability. The STARD statement, checklist, flowchart and this explanation and elaboration document should be useful resources to improve reporting of diagnostic accuracy studies. Complete and informative reporting can only lead to better decisions in healthcare.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The authors describe a reverse-phase high-performance liquid chromatography-electrospray-tandem mass spectrometry method for the measurement of nicotine in human plasma. Samples (500 muL) with added deuterium-labeled d(3)-nicotine as an internal standard (IS) were treated with a 2-step process of ether extraction (6 mL) followed by back-extraction into 0.1% formic acid (50 muL). Chromatography was performed on a phenyl Novapak column with a mobile phase consisting of 50% 10 mM ammonium fortriate (pH 3.3) and acetonitrile (50:50, vol/vol). A flow rate of 0.2 mL/min resulted in a total analysis time of 5 minutes per sample. Mass spectrometric detection was by selected reactant monitoring (nicotine m/z 163.2 --> 130.2; IS m/z 166.2 --> 87.2). The assay was linear from 0.5 to 100 mug/L (r > 0.993, n = 9). The accuracy and imprecision of the method for quality control sampleswere 87.5% to 113% and < 10.2%, respectively. Interday accuracy and imprecision at the limit of quantification (0.5 mug/L) was 113% and 7.2% (n = 4). The process efficiency for nicotine in plasma was > 75%. The method described has good process efficiency, stabilized nicotine, avoided concentration steps, and most importantly minimized potential contamination. Further, we have established that water-based standards and controls are interchangeable with plasma-based samples. This method was used successfully to measure the pharmacokinetic profiles of subjects involved in the development of an aerosol inhalation drug delivery system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to determine the most informative sampling time(s) providing a precise prediction of tacrolimus area under the concentration-time curve (AUC). Fifty-four concentration-time profiles of tacrolimus from 31 adult liver transplant recipients were analyzed. Each profile contained 5 tacrolimus whole-blood concentrations (predose and 1, 2, 4, and 6 or 8 hours postdose), measured using liquid chromatography-tandem mass spectrometry. The concentration at 6 hours was interpolated for each profile, and 54 values of AUC(0-6) were calculated using the trapezoidal rule. The best sampling times were then determined using limited sampling strategies and sensitivity analysis. Linear mixed-effects modeling was performed to estimate regression coefficients of equations incorporating each concentration-time point (C0, C1, C2, C4, interpolated C5, and interpolated C6) as a predictor of AUC(0-6). Predictive performance was evaluated by assessment of the mean error (ME) and root mean square error (RMSE). Limited sampling strategy (LSS) equations with C2, C4, and C5 provided similar results for prediction of AUC(0-6) (R-2 = 0.869, 0.844, and 0.832, respectively). These 3 time points were superior to C0 in the prediction of AUC. The ME was similar for all time points; the RMSE was smallest for C2, C4, and C5. The highest sensitivity index was determined to be 4.9 hours postdose at steady state, suggesting that this time point provides the most information about the AUC(0-12). The results from limited sampling strategies and sensitivity analysis supported the use of a single blood sample at 5 hours postdose as a predictor of both AUC(0-6) and AUC(0-12). A jackknife procedure was used to evaluate the predictive performance of the model, and this demonstrated that collecting a sample at 5 hours after dosing could be considered as the optimal sampling time for predicting AUC(0-6).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The current approach for therapeutic drug monitoring in renal transplant recipients receiving mycophenolate mofetil (MMF) is measurement of total mycophenolic acid (MPA) concentration. Because MPA is highly bound, during hypoalbuminemia the total concentration no longer reflects the free (pharmacologically active) concentration. The authors investigated what degree of hypoalbuminemia causes a significant change in protein binding and thus percentage free MPA. Forty-two renal transplant recipients were recruited for the study. Free and total concentrations of MPA (predose, and 1, 3, and 6 hours post-MMF dose samples) and plasma albumin concentrations were determined on day 5 posttransplantation. Six-hour area under the concentration-time curve (AUC(0-6)) values were calculated for free and total MPA, and percentage free MPA was determined for each patient. The authors found a significant relationship between low albumin concentrations and increased percentage free MPA (Spearman correlation = -0.54, P < 0.0001). Receiver operating characteristic (ROC) curve analysis was performed on the albumin versus percentage free MPA data. The cutoff value of albumin determined from the ROC analysis that differentiated normal from elevated percentage free MPA (defined as greater than or equal to3%) in this patient population was 31 g/L. At this cutoff value albumin was found to be a good predictor of altered free MPA percentage, with a sensitivity and specificity of 0.75 and 0.80, respectively, and an area under the ROC curve of 0.79. To rationalize MMF dosing regimens in hypoalbuminemic patients (plasma albumin less than or equal to 31 g/L), clinicians should consider monitoring the free MPA concentration.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Renal transplant recipients were noted to appear cushingoid while on low doses of steroid as part of a triple therapy immunosuppression of cyclosporin A (CsA), prednisolone, and azathioprine. Methods: The study group comprised adult renal transplant recipients with stable graft function who had received their renal allograft a minimum of 1 year previously (43 studies undertaken in 22 men and 20 women) with median daily prednisone dose of 7 mg (range 3-10). The control group was healthy nontransplant subjects [median dose 10 mg (10-30)]. Prednisolone bioavailability was measured using a limited 6-hour area under the curve (AUC), with prednisolone measured using specific HPLC assay. Results: The median prednisolone AUC/mg dose for all transplant recipients was significantly greater than the control group by approximately 50% (316 nmol(.)h/L/mg prednisolone versus 218). AUC was significantly higher in female recipients (median 415 versus 297 for men) and in recipients receiving cyclospotin (348 versus 285). The highest AUC was in women on estrogen supplements who were receiving cyclosporin (median 595). A significantly higher proportion of patients on triple therapy had steroid side effects compared with those on steroid and azathioprine (17/27 versus 4/15), more women than men had side effects (14/16 versus 7/22), and the AUC/mg prednisone was greater in those with side effects than without (median 377 versus 288 nmol-h/L/mg). Discussion: The results are consistent with the hypothesis that CsA increases the bioavailability of prednisolone, most likely through inhibition of beta-glycoprotein. The increased exposure to steroid increased the side-effect profile of steroids in the majority of patients. Because the major contributor to AUC is the maximum postdose concentration, it may be possible to use single-point monitoring (2 hours postdose) for routine clinical studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: Cyclosporin is an immunosuppressant drug with a narrow therapeutic window. Trough and 2-h post-dose blood samples are currently used for therapeutic drug monitoring in solid organ transplant recipients. The aim of the current study was to develop a rapid HPLC-tandem mass spectrometry (HPLC-MS) method for the measurement of cyclosporin in whole blood that was not only suitable for the clinical setting but also considered a reference method. Methods: Blood samples (50 mu L) were prepared by protein precipitation followed by C-18 solid-phase extraction while using d(12) cyclosporin as the internal standard. Mass spectrometric detection was by selected reaction monitoring with an electrospray interface in positive ionization mode. Results: The assay was linear from 10 to 2000 mu g/L (r(2) > 0.996, n = 9). Inter-day,analytical recovery and imprecision using whole blood quality control samples at 10, 30, 400, 1500, and 2000 mu g/L were 94.9-103.5% and

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The role of the therapeutic drug monitoring laboratory in support of immunosuppressant drug therapy is well established, and the introduction of sirolimus (SRL) is a new direction in this field. The lack of an immunoassay for several years has restricted the availability of SRL assay services. The recent availability of a CEDIA (R) SRL assay has the potential to improve this situation. The present communication has compared the CEDIA (R) SRL method with 2 established chromatographic methods, HPLC-UV and HPLC-MS/MS. The CEDIA (R) method, run on a Hitachi 917 analyzer, showed acceptable validation criteria with within-assay precision of 9.1% and 3.3%, and bias of 17.1% and 5.8%, at SRL concentrations of 5.0 mu g/L and 20 mu g/L, respectively. The corresponding between-run precision values were 11.5% and 3.3% and bias of 7.1% and 2.9% at 5.0 mu g/L and 20 mu g/L, respectively, The lower limit of quantification was found to be 3.0 mu g/L. A series of 96 EDTA whole-blood samples predominantly from renal transplant recipients were assayed by the 3 methods for comparison. It was found that the CEDIA (R) method showed a Deming regression line of CEDIA = 1.20 X HPLC-MS/MS - 0.07 (r = 0.934, SEE = 1.47), with a mean bias of 20.4%. Serial blood samples from 8 patients included in this evaluation showed that the CEDIA (R) method reflected the clinical fluctuations in the chromatographic methods, albeit with the variable bias noted. The CEDIA (R) method on the H917 analyzer is therefore a useful adjunct to SRL dosage individualization in renal transplant recipients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We observed unexpected high plasma concentrations of tobrarriycin (48.5 and 28.1 mg/L) in fingerprick blood samples after the nebulization of tobramycin solution for inhalation (tobramycin 300 mg/5 mL, TOBI(R)) by 2 young children aged 3 years. To investigate whether dermal contamination could be the source of error, 3 adult volunteers were present during another nebulization by a third child (age 2 years). The volunteers had exposure to tobramycin by handling the nebulizer or the nebule and also by inhalation from holding the child and being in close proximity while TOBI(R) was being administered. Five blood samples by fingerprick and 2 by venipuncture were collected and assayed for tobramycin concentration. On each occasion the site was swabbed with alcohol wipes to mimic standard patient sampling methods. One site was resampled after cleaning of hands with 2% chlorhexidine gluconate and water. Tobramycin concentrations from venipuncture 1-2 hours after nebulization were all < 0.2 mg/L except for 1 result of 1.2 mg/L. The tobramycin concentrations from fingerpricks before hand washing varied between 6.8 and 172 mg/L, and after hand washing between 0.3 and 17.6 mg/L. Contamination of fingers with tobramycin is likely to have caused the error in the 2 initial cases and did cause misleadingly elevated levels in the adult volunteers. We caution that therapeutic drug monitoring of nebulized tobramycin should not be done by fingerprick sampling, and care should be taken to avoid contamination of the venipuncture site.