Resumo:
This paper presents a non-invasive approach for diagnosing winding insulation failures in three-phase transformers, which is based on the on-line monitoring of the primary and secondary current Park's Vector. Experimental and simulated results demonstrate the effectiveness of the proposed technique, for detecting winding inter-turn insulation faults in operating three-phase transformers.
Resumo:
This paper presents the development of a new approach for diagnosing the occurrence of inter-turn short-circuits in the windings of three-phase transformers, which is based on the on-line monitoring of the on-load exciting current Park's Vector patterns. Experimental and simulated results demonstrate the effectiveness of the proposed technique for detecting winding inter-turn insulation faults in operating three-phase transformers.
Resumo:
This paper addresses the subject of condition monitoring and diagnostics of power transformers. The main results of two reliability surveys, carried out under the auspices of CIGRE and IEEE in order to assemble objective data on the performance of transformers in service, are presented, providing useful information on the main causes of transformer failures, the most likely affected components and the related outages times. A survey of the most important methods, actually in use, for condition monitoring and diagnostics of power transformers is also given, which stresses the need for the development of new diagnostic methods, that can be applied without taking the transformers out of service, and that can also provide a fault severity criteria, in particular for determining transformers windings integrity. Preliminary results, concerning the on-going research activity on the development of a new approach for inter-turn winding fault diagnosis in three-phase transformers, are also reported in the paper.
Resumo:
This paper addresses the subject of condition monitoring and diagnostics of power transformers. The main results of two reliability surveys, carried out under the auspices of CIGRE and IEEE in order to assemble objective data on the performance of transformers in service, are presented, providing useful information on the main causes of transformer failures, the most likely affected components and the related outages times. A survey of the most important methods, actually in use, for condition monitoring and diagnostics of power transformers is also given, which stresses the need for the development of new diagnostic methods, that can be applied without taking the transformers out of service, and that can also provide a fault severity criteria, in particular for determining transformers windings integrity. Preliminary results, concerning the on-going research activity on the development of a new approach for inter-turn winding fault diagnosis in three-phase transformers, are also reported in the paper.
Resumo:
The Portuguese Association of Automatic Control (APCA) organizes, every two years, the Portuguese Conference on Automatic Control. Its 6th edition (Controlo 2004) was held from 7 to 9 June, 2004 at the University of Algarve, Faro, Portugal, by its Centre for Intelligent Systems (CSI). CONTROLO 2004 International Program Committee (IPC) has decided, from the very start, to ask for submission of full draft papers, to encourage special sessions with well-defined themes, and for student papers. All papers have been reviewed by three separate reviewers. From the 122 contributions submitted, the IPC selected 89 oral papers, 20 special session papers, and 5 student posters. CONTROLO 2004 Technical Programme consists of 33 oral sessions (5 being special sessions) and 1 poster session, covering a broad range of control topics, both from theory and applications. The programme also includes three plenary lectures, given by leading experts in the field, Professors Ricardo Sanz, João Miranda Lemos and Rolf Isermann.
Resumo:
The introduction of parallel processing architectures allowed the real time impelemtation of more sophisticated control algorithms with tighter specifications in terms of sampling time. However, to take advantage of the processing power of these architectures the control engeneer, due to the lack of appropriate tools, must spend a considerable amount of time in the parallelizaton of the control algorithm.
Resumo:
Neural networks and genetic algorithms have been in the past successfully applied, separately, to controller turning problems. In this paper we propose to combine its joint use, by exploiting the nonlinear mapping capabilites of neural networks to model objective functions, and to use them to supply their values to a genetic algorithm which performs on-line minimization.
Resumo:
In this work, a comprehensive review on automatic analysis of Proteomics and Genomics images is presented. Special emphasis is given to a particularly complex image produced by a technique called Two-Dimensional Gel Electrophoresis (2-DE), with thousands of spots (or blobs). Automatic methods for the detection, segmentation and matching of blob like features are discussed and proposed. In particular, a very robust procedure was achieved for processing 2-DE images, consisting mainly of two steps: a) A very trustworthy new approach for the automatic detection and segmentation of spots, based on the Watershed Transform, without any foreknowledge of spot shape or size, and without user intervention; b) A new method for spot matching, based on image registration, that performs well for either global or local distortions. The results of the proposed methods are compared to state-of-the-art academic and commercial products.