13 resultados para Diagnóstico por imagem - Técnicas digitais

em Repositório Institucional da Universidade de Aveiro - Portugal


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the past few years a new generation of multifunctional nanoparticles (NPs) has been proposed for biomedical applications, whose structure is more complex than the structure of their predecessor monofunctional counterparts. The development of these novel NPs aims at enabling or improving the performance in imaging, diagnosis and therapeutic applications. The structure of such NPs comprises several components exhibiting various functionalities that enable the nanoparticles to perform multiple tasks simultaneously, such as active targeting of certain cells or compartmentalization, imaging and delivery of active drugs. This thesis presents two types of bimodal bio-imaging probes and describes their physical and chemical properties, namely their texture, structure, and 1H dynamics and relaxometry, in order to evaluate their potential as MRI contrast agents. The photoluminescence properties of these probes are studied, aiming at assessing their interest as optical contrast agents. These materials combine the properties of the trivalent lanthanide (Ln3+) complexes and nanoparticles, offering an excellent solution for bimodal imaging. The designed T1- type contrast agent are SiO2@APS/DTPA:Gd:Ln or SiO2@APS/PMN:Gd:Ln (Ln= Eu or Tb) systems, bearing the active magnetic center (Gd3+) and the optically-active ions (Eu3+ and Tb3+) on the surface of silica NPs. Concerning the relaxometry properties, moderate r1 increases and significant r2 increases are observed in the NPs presence, especially at high magnetic fields, due to susceptibility effects on r2. The Eu3+ ions reside in a single low-symmetry site, and the photoluminescence emission is not influenced by the simultaneous presence of Gd3+ and Eu3+. The presence of Tb3+, rather than Eu3+ ion, further increases r1 but decreases r2. The uptake of these NPs by living cells is fast and results in an intensity increase in the T1-weighted MRI images. The optical features of the NPs in cellular pellets are also studied and confirm the potential of these new nanoprobes as bimodal imaging agents. This thesis further reports on a T2 contrast agent consisting of core-shell NPs with a silica shell surrounding an iron oxide core. The thickness of this silica shell has a significant impact on the r2 and r2* relaxivities, and a tentative model is proposed to explain this finding. The cell viability and the mitochondrial dehydrogenase expression given by the microglial cells are also evaluated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O objetivo deste trabalho foi efetuar um estudo de otimização dos parâmetros de exposição do mamógrafo digital da marca GE, modelo Senographe DS instalado no Instituto Português de Oncologia de Coimbra (IPOC) baseado numa análise contraste detalhe e avaliar o impacto do resultado obtido na melhoria da capacidade de detecção clínica das estruturas da mama. O mamógrafo em estudo dispõe de um sistema de controle automático da exposição designado por sistema AOP (Automatic Optimization of Parameters) que foi otimizado pelo fabricante a partir da razão contraste ruído. O sistema AOP é usado na prática clínica na quase totalidade dos exames de mamografia realizados no IPOC. Tendo em conta o tipo de estrutura que se pretende visualizar na mamografia, nomeadamente estruturas de baixo contraste como as massas e estruturas de dimensão submilimétrica como as microcalcificações, a análise contraste detalhe poderia constituir uma abordagem mais adequada para o estudo de otimização dos parâmetros de exposição uma vez que permitiria uma avaliação conjunta do contraste, da resolução espacial e do ruído da imagem. Numa primeira fase do trabalho foi efetuada a caracterização da prática clínica realizada no mamógrafo em estudo em termos de espessura de mama comprimida “típica”, dos parâmetros técnicos de exposição e das opções de processamento das imagens aplicadas pelo sistema AOP (combinação alvo/filtro, tensão aplicada na ampola - kVp e produto corrente-tempo da ampola - mAs). Numa segunda fase foi realizado um estudo de otimização da qualidade da imagem versus dose na perspectiva dos parâmetros físicos. Para tal foi efetuada uma análise contrastedetalhe no objeto simulador de mama CDMAM e usada uma figura de mérito definida a partir do IQFinv (inverted image quality figure) e da dose glandular média. Os resultados apontaram para uma diferença entre o ponto ótimo resultante do estudo de otimização e o ponto associado aos parâmetros de exposição escolhidos pelo sistema AOP, designadamente no caso da mama pequena. Sendo a qualidade da imagem na perspectiva clínica um conceito mais complexo cujo resultado da apreciação de uma imagem de boa qualidade deve ter em conta as diferenças entre observadores, foi efetuado na última parte deste trabalho um estudo do impacto clínico da proposta de otimização da qualidade de imagem. A partir das imagens realizadas com o objeto simulador antropomórfico TOR MAM simulando uma mama pequena, seis médicos(as) radiologistas com mais de 5 anos de experiência em mamografia avaliaram as imagens “otimizadas” obtidas utilizando-se os parâmetros técnicos de exposição resultantes do estudo de otimização e a imagem resultante da escolha do sistema AOP. A análise estatística das avaliações feitas pelos médicos indica que a imagem “otimizada” da mama pequena apresenta uma melhor visualização das microcalcificações sem perda da qualidade da imagem na deteção de fibras e de massas em comparação com a imagem “standard”. Este trabalho permitiu introduzir uma nova definição da figura de mérito para o estudo de otimização da qualidade da imagem versus dose em mamografia. Permitiu também estabelecer uma metodologia consistente que pode facilmente ser aplicada a qualquer outro mamógrafo, contribuindo para a área da otimização em mamografia digital que é uma das áreas mais relevantes no que toca à proteção radiológica do paciente.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Estudar os mecanismos subjacentes à produção de fala é uma tarefa complexa e exigente, requerendo a obtenção de dados mediante a utilização de variadas técnicas, onde se incluem algumas modalidades imagiológicas. De entre estas, a Ressonância Magnética (RM) tem ganho algum destaque, nos últimos anos, posicionando-se como uma das mais promissoras no domínio da produção de fala. Um importante contributo deste trabalho prende-se com a otimização e implementação de protocolos (RM) e proposta de estratégias de processamento de imagem ajustados aos requisitos da produção de fala, em geral, e às especificidades dos diferentes sons. Para além disso, motivados pela escassez de dados para o Português Europeu (PE), constitui-se como objetivo a obtenção de dados articulatórios que permitam complementar informação já existente e clarificar algumas questões relativas à produção dos sons do PE (nomeadamente, consoantes laterais e vogais nasais). Assim, para as consoantes laterais foram obtidas imagens RM (2D e 3D), através de produções sustidas, com recurso a uma sequência Eco de Gradiente (EG) rápida (3D VIBE), no plano sagital, englobando todo o trato vocal. O corpus, adquirido por sete falantes, contemplou diferentes posições silábicas e contextos vocálicos. Para as vogais nasais, foram adquiridas, em três falantes, imagens em tempo real com uma sequência EG - Spoiled (TurboFLASH), nos planos sagital e coronal, obtendo-se uma resolução temporal de 72 ms (14 frames/s). Foi efetuada aquisição sincronizada das imagens com o sinal acústico mediante utilização de um microfone ótico. Para o processamento e análise de imagem foram utilizados vários algoritmos semiautomáticos. O tratamento e análise dos dados permitiu efetuar uma descrição articulatória das consoantes laterais, ancorada em dados qualitativos (e.g., visualizações 3D, comparação de contornos) e quantitativos que incluem áreas, funções de área do trato vocal, extensão e área das passagens laterais, avaliação de efeitos contextuais e posicionais, etc. No que respeita à velarização da lateral alveolar /l/, os resultados apontam para um /l/ velarizado independentemente da sua posição silábica. Relativamente ao /L/, em relação ao qual a informação disponível era escassa, foi possível verificar que a sua articulação é bastante mais anteriorizada do que tradicionalmente descrito e também mais extensa do que a da lateral alveolar. A resolução temporal de 72 ms conseguida com as aquisições de RM em tempo real, revelou-se adequada para o estudo das características dinâmicas das vogais nasais, nomeadamente, aspetos como a duração do gesto velar, gesto oral, coordenação entre gestos, etc. complementando e corroborando resultados, já existentes para o PE, obtidos com recurso a outras técnicas instrumentais. Para além disso, foram obtidos novos dados de produção relevantes para melhor compreensão da nasalidade (variação área nasal/oral no tempo, proporção nasal/oral). Neste estudo, fica patente a versatilidade e potencial da RM para o estudo da produção de fala, com contributos claros e importantes para um melhor conhecimento da articulação do Português, para a evolução de modelos de síntese de voz, de base articulatória, e para aplicação futura em áreas mais clínicas (e.g., perturbações da fala).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A inovação tecnológica e as facilidades que gera tem tido um impacto crescente em diversas área, inclusivamente na medicina. A rápida evolução por parte de algumas tecnologias, como é o caso da Realidade Aumentada (RA), criam excelentes oportunidades, nomeadamente para intervenções cirúrgicas laparoscópicas, que apresentam especialmente problemas ao nível da exposição do doente a radiação. O presente documento detalha todo o processo de investigação e desenvolvimento realizado com a pretensão de criar um sistema de navegação por RA que auxilie o procedimento cirúrgico laparoscópico de remoção de pedras nos rins. Com este objetivo em perspetiva, e numa parceria com a empresa ECmedica LTD, foram desenvolvidos quatro protótipo funcionais. Com o intuito de compreender as melhores práticas de sistemas de input, interface e sistema de registo a aplicar, estes integraram aspetos inovadores tais como a utilização de uma sonda ultra-som, como substituta do raioX, e um registo feito através de sensores magnéticos. Apoiados numa metodologia de design centrado no utilizador e em instrumentos de análise como entrevistas e observação natural, os protótipos foram testados, obtendo respostas esclarecedoras relativamente ao objetivos dos protótipos. Foi observado que a RA é vista pelos médicos como uma solução com potencial, com as soluções apresentadas ao nível de inputs, interface e registo a serem bem recebidas. A projeção bidimensional oferecida pela imagem ultra-som foi encarada como insuficientes, sendo sugerida a sua substituição por um aumento tridimensional capaz de facilitar a correta inserção da agulha.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O sindroma de Burnout, quadro psicofisio-patológico tem sido objecto de investigação intensiva, desde o artigo de Freudenberger (1974) intitulado "Staff Burnout", com dois objectivos: compreendê-lo melhor, através de meios de diagnóstico, e criar técnicas de intervenção terapêutica. Na realidade, desde essa altura, foram efectuados e publicados um número avultado de trabalhos de investigação, nos campos do diagnóstico e caracterização do Burnout, e da sua resolução terapêutica. O pensamento dominante, nessa altura e ainda hoje, é de tendência analítica e/ou psico-social. Este quadro, espoletado por uma sucessão de episódios emocionalmente negativos em contexto ocupacional em indivíduos com provável predisposição genética e sujeitos a situações de pressão laboral, dos mais diversos tipos (podendo ir do “simples” stress por acumulação de tarefas até às situações de mobbing), tem efeitos frequentemente dramáticos ao nível da dinâmica biopsico- social, nos seus mais diversos aspectos. Estes estendem-se, quase sempre, muito para lá das problemáticas laborais, prejudicando, de forma mais ou menos grave, as interacções sociais com particular impacto ao nível da dinâmica familiar. Por outro lado, o Burnout propicia o aparecimento de patologias diversas, já que toda a estrutura psiconeuro-endocrino-imunulógica estará posta em causa, potenciando situações de fragilidade sistémica. No entanto, há aspectos correlacionáveis com este quadro disfuncional que têm sido muito pouco abordados – alterações cognitivo-operativas ou neuropsicológicas. Aliás os trabalhos que sobre eles incidem são em número muito reduzido. Assim após termos registado queixas, acentuadas, ao nível da capacidade de concentração e da memória em pessoas com burnout observadas na clínica hospitalar e privada, decidimos investigar estas situações, usando uma metodologia clínica de tipo qualitativo, e constatámos que, na realidade, as queixas eram pertinentes. Posto isto, achámos que a situação deveria ser aprofundada e partimos para um trabalho mais sistematizado, este, com o objectivo de caracterizar melhor o tipo de disfunções atencionais e mnésicas. Para isso, após uma selecção prévia, a partir de um grupo de 192 enfermeiros que responderam à Escala de Maslach, avaliámos uma amostra de risco constituída por 40 enfermeiros e enfermeiras, de Instituições Psiquiátricas da Grande Lisboa, trabalhando em urgência e enfermaria, que comparámos com uma amostra de igual número de enfermeiros, desenvolvendo a sua actividade na consulta externa ou em ambientes mais protegidos de stress ocupacional continuo. Para o efeito, e após uma anamnese cuidada, aplicámos provas de atenção e memória, sensíveis a qualquer tipo de compromisso encefálico seja ele funcional ou patológico. Para a componente atenção/concentração e a componente vísuo-grafo-espacial usámos a prova de Toulouse-Piéron, assim como as séries de dígitos ou digit span, para a vertente audio-verbal. A dinâmica mnésica foi avaliada através da prova de memória associativa (Escala de Memória de Wechsler) para testar a variante áudio-verbal, e a reprodução de figuras (Escala de Memória de Wechlser). Os resultados, após uma dupla análise clínica e estatística, comprovaram globalmente as hipóteses, indicando uma correlação significativa entre o grau de Burnout e os défices neuropsicológicos detectados: alteração da atenção/concentração e dismnésia, de natureza limitativa face às exigências quotidianas dos indivíduos. Finalmente, com base na revisão da literatura e os resultados deste estudo, foi esquematizado um Modelo Neuropsicológico do sindroma de Burnout, que nos parece espelhar as relações entre este quadro clínico, as alterações cognitivooperativas encontradas e as principais estruturas encefálicas, que julgamos, implicadas em toda a dinâmica do processo disfuncional.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work presents the results on the development of a high pressure Xe gaseous detector envisaging medical imaging. The detector uses two VUV photosensors operating face-to-face, based on the CsI-MHSP with position discrimination capability. The known effect of the charge gain decrease with the gas pressure is compensated with a light gain using the electroluminescence process. Studies of signal amplitude, energy and position resolution are presented. On the second part, gaseous detectors based on THGEM where studied in order to fulfill the requirements of present and future high energy physics experiments. The work is focused on the application of THGEM in RICH detectors elements: a triple THGEM detector using CsI photocathodes in Ne mixtures was suggested. The ion backflow to the photocathode remains a concern and a limitation; to minimize it, the application of a new hole-structure, THCOBRA, was suggested. Preliminary results foresee good perspectives for the successful application of THCOBRA in ion back-flow suppression. This work contains several methods and measurements of the CsI photocathodes behaviour in radiation gaseous detectors. A long discussion on its issues and possible solutions are presented.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coronary CT angiography is widely used in clinical practice for the assessment of coronary artery disease. Several studies have shown that the same exam can also be used to assess left ventricle (LV) function. LV function is usually evaluated using just the data from end-systolic and end-diastolic phases even though coronary CT angiography (CTA) provides data concerning multiple cardiac phases, along the cardiac cycle. This unused wealth of data, mostly due to its complexity and the lack of proper tools, has still to be explored in order to assess if further insight is possible regarding regional LV functional analysis. Furthermore, different parameters can be computed to characterize LV function and while some are well known by clinicians others still need to be evaluated concerning their value in clinical scenarios. The work presented in this thesis covers two steps towards extended use of CTA data: LV segmentation and functional analysis. A new semi-automatic segmentation method is presented to obtain LV data for all cardiac phases available in a CTA exam and a 3D editing tool was designed to allow users to fine tune the segmentations. Regarding segmentation evaluation, a methodology is proposed in order to help choose the similarity metrics to be used to compare segmentations. This methodology allows the detection of redundant measures that can be discarded. The evaluation was performed with the help of three experienced radiographers yielding low intraand inter-observer variability. In order to allow exploring the segmented data, several parameters characterizing global and regional LV function are computed for the available cardiac phases. The data thus obtained is shown using a set of visualizations allowing synchronized visual exploration. The main purpose is to provide means for clinicians to explore the data and gather insight over their meaning, as well as their correlation with each other and with diagnosis outcomes. Finally, an interactive method is proposed to help clinicians assess myocardial perfusion by providing automatic assignment of lesions, detected by clinicians, to a myocardial segment. This new approach has obtained positive feedback from clinicians and is not only an improvement over their current assessment method but also an important first step towards systematic validation of automatic myocardial perfusion assessment measures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The development of a compact gamma camera with high spatial resolution is of great interest in Nuclear Medicine as a means to increase the sensitivity of scintigraphy exams and thus allow the early detection of small tumours. Following the introduction of the wavelength-shifting fibre (WSF) gamma camera by Soares et al. and evolution of photodiodes into highly sensitive silicon photomultipliers (SiPMs), this thesis explores the development of a WSF gamma camera using SiPMs to obtain the position information of scintillation events in a continuous CsI(Na) crystal. The design is highly flexible, allowing the coverage of different areas and the development of compact cameras, with very small dead areas at the edges. After initial studies which confirmed the feasibility of applying SiPMs, a prototype with 5 5 cm2 was assembled and tested at room temperature, in an active field-of-view of 10 10 mm2. Calibration and characterisation of intrinsic properties of this prototype were done using 57Co, while extrinsic measurements were performed using a high-resolution parallel-hole collimator and 99mTc. In addition, a small mouse injected with a radiopharmaceutical was imaged with the developed prototype. Results confirm the great potential of SiPMs when applied in a WSF gamma camera, achieving spatial resolution performance superior to the traditional Anger camera. Furthermore, performance can be improved by an optimisation of experimental conditions, in order to minimise and control the undesirable effects of thermal noise and non-uniformity of response of multiple SiPMs. The development and partial characterisation of a larger SiPM WSF gamma camera with 10 10 cm2 for clinical application are also presented.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The last decades have been characterized by a continuous adoption of IT solutions in the healthcare sector, which resulted in the proliferation of tremendous amounts of data over heterogeneous systems. Distinct data types are currently generated, manipulated, and stored, in the several institutions where patients are treated. The data sharing and an integrated access to this information will allow extracting relevant knowledge that can lead to better diagnostics and treatments. This thesis proposes new integration models for gathering information and extracting knowledge from multiple and heterogeneous biomedical sources. The scenario complexity led us to split the integration problem according to the data type and to the usage specificity. The first contribution is a cloud-based architecture for exchanging medical imaging services. It offers a simplified registration mechanism for providers and services, promotes remote data access, and facilitates the integration of distributed data sources. Moreover, it is compliant with international standards, ensuring the platform interoperability with current medical imaging devices. The second proposal is a sensor-based architecture for integration of electronic health records. It follows a federated integration model and aims to provide a scalable solution to search and retrieve data from multiple information systems. The last contribution is an open architecture for gathering patient-level data from disperse and heterogeneous databases. All the proposed solutions were deployed and validated in real world use cases.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Esta tese pretende contribuir para o estudo e análise dos factores relacionados com as técnicas de aquisição de imagens radiológicas digitais, a qualidade diagnóstica e a gestão da dose de radiação em sistema de radiologia digital. A metodologia encontra-se organizada em duas componentes. A componente observacional, baseada num desenho do estudo de natureza retrospectiva e transversal. Os dados recolhidos a partir de sistemas CR e DR permitiram a avaliação dos parâmetros técnicos de exposição utilizados em radiologia digital, a avaliação da dose absorvida e o índice de exposição no detector. No contexto desta classificação metodológica (retrospectiva e transversal), também foi possível desenvolver estudos da qualidade diagnóstica em sistemas digitais: estudos de observadores a partir de imagens arquivadas no sistema PACS. A componente experimental da tese baseou-se na realização de experiências em fantomas para avaliar a relação entre dose e qualidade de imagem. As experiências efectuadas permitiram caracterizar as propriedades físicas dos sistemas de radiologia digital, através da manipulação das variáveis relacionadas com os parâmetros de exposição e a avaliação da influência destas na dose e na qualidade da imagem. Utilizando um fantoma contrastedetalhe, fantomas antropomórficos e um fantoma de osso animal, foi possível objectivar medidas de quantificação da qualidade diagnóstica e medidas de detectabilidade de objectos. Da investigação efectuada, foi possível salientar algumas conclusões. As medidas quantitativas referentes à performance dos detectores são a base do processo de optimização, permitindo a medição e a determinação dos parâmetros físicos dos sistemas de radiologia digital. Os parâmetros de exposição utilizados na prática clínica mostram que a prática não está em conformidade com o referencial Europeu. Verifica-se a necessidade de avaliar, melhorar e implementar um padrão de referência para o processo de optimização, através de novos referenciais de boa prática ajustados aos sistemas digitais. Os parâmetros de exposição influenciam a dose no paciente, mas a percepção da qualidade de imagem digital não parece afectada com a variação da exposição. Os estudos que se realizaram envolvendo tanto imagens de fantomas como imagens de pacientes mostram que a sobreexposição é um risco potencial em radiologia digital. A avaliação da qualidade diagnóstica das imagens mostrou que com a variação da exposição não se observou degradação substancial da qualidade das imagens quando a redução de dose é efectuada. Propõe-se o estudo e a implementação de novos níveis de referência de diagnóstico ajustados aos sistemas de radiologia digital. Como contributo da tese, é proposto um modelo (STDI) para a optimização de sistemas de radiologia digital.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Na era da convergência jornalística, as redações televisivas estão, ainda, a passar por diversos processos de transformações. Centrando esta problemáti-ca nos telejornalistas, verifica-se uma tendência crescente para que estes de-sempenhem funções e/ou tarefas que ainda há muito pouco tempo eram exe-cutadas por outros profissionais da informação televisiva. Esta agregação fun-cional verifica-se, nomeadamente, ao nível da edição de imagem de conteúdos noticiosos a serem transmitidos pela televisão. Neste contexto, na presente tese de doutoramento pretende-se, em termos gerais, apurar e compreender as causas e as consequências de serem os próprios jornalistas televisivos a desempenhar a edição de imagem de conteúdos noticiosos transmitidos pela televisão. Para isso, foi desenvolvida uma investigação empírica, tendo como campos de estudo as redações centrais da SIC e da TVI. Tal como o trabalho de campo permitiu concluir, os diversos fundamen-tos desta dinâmica são, de certa forma, incontornáveis. Contudo, esta investi-gação pretende também contribuir para que se reúnam as condições, ao nível da oferta formativa, que tornem as respetivas consequências consonantes com uma evolução profícua da atividade jornalística.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The development of computed tomography systems with energy resolving detectors is a current challenge in medical physics and biomedical engineering. A computed tomography system of this kind allows getting complementary informations relatively to conventional systems, that can help the medical diagnosis, being of great interest in medicine. The work described in this thesis is related to the development of a computed tomography system using micropattern gaseous detectors, which allow storing, simultaneously, information about the interaction position and the energy of each single photon that interacts with the detector. This kind of detectors has other advantages concerning the cost and characteristics of operation when compared with solid state detectors. Tomographic acquisitions were performed using a MicroHole & Strip Plate based detector, which allowed reconstructing cross-sectional images using energy windows, applying the energy weighting technique and performing multi-slice and tri-dimensional reconstructions. The contrast-to-noise ratio was improved by 31% by applying the energy weighting technique, comparing with the corresponding image obtained with the current medical systems. A prototype of a computed tomography with flexibility to change the detector was developed, making it possible to apply different detectors based on Thick-COBRA. Several images acquired with these detectors are presented and demonstrate their applicability in X-ray imaging. When operating in NeCH4, the detector allowed a charge gain of 8 104, an energy resolution of 20% (full width at half maximum at 8 keV), a count rate of 1 106 Hz/mm2, a very stable operation (gain fluctuations below 5%) and a spacial resolution of 1.2 mm for an energy photon of 3.6 keV. Operating the detector in pure Kr allowed increasing the detection efficiency and achieving a charge gain of 2 104, an energy resolution of 32% (full width at half maximum at 22 keV), a count rate of 1 105 Hz/mm2, very stable operation and a spatial resolution of 500 m. The software already existing in the group was improved and tools to correct geometric misalignments of the system were also developed. The reconstructions obtained after geometrical correction are free of artefacts due to the referred misalignments.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A utilização das TIC ocupam um lugar cada vez mais importante nas nossas escolas, marcado sobretudo pela evolução das tecnologias e pela utilização em contexto educativo de muitas ferramentas da Web 2.0. Esse facto é muito notório na disciplina de Educação Visual e Tecnológica, de carácter eminentemente prático, onde é permitido explorar várias ferramentas digitais para abordagem de conteúdos da disciplina e para a criação de produtos gráficos e plásticos. Com o aparecimento da Web 2.0 e a disponibilização de milhares de novas ferramentas digitais aos utilizadores da Internet, estimula-se um interesse cada vez maior na adoção de metodologias e estratégias com recurso a estes media e que suportem uma aprendizagem mais eficaz e motivadora para os alunos, articulando-se os suportes tradicionais de EVT com os novos media digitais. Neste contexto, o presente estudo é o resultado duma investigação-ação realizada no âmbito do Programa Doutoral em Multimédia em Educação da Universidade de Aveiro onde se implementou a integração de ferramentas da Web, Web 2.0 e Software Livre em contexto educativo na disciplina de EVT, na qual poderiam ser utilizadas tanto as técnicas tradicionais de realização mais usuais na disciplina como a integração e articulação com as ferramentas digitais, suportadas por software livre (e outros de utilização gratuita), a Web e a Web 2.0 para suporte ao ensino e aprendizagem dos diversos conteúdos e áreas de exploração da disciplina. Este estudo, desenhado em três ciclos, envolveu num primeiro momento a constituição de uma comunidade de prática de professores alargada, sendo criadas seis turmas de formação que reuniram um total de 112 professores que pretendiam integrar as ferramentas digitais em EVT. Para além da pesquisa, análise, seleção e catalogação destas 430 ferramentas digitais recenseadas, produziram-se 371 manuais de apoio à utilização das mesmas, sendo estes recursos disponibilizados no espaço do EVTdigital. Num segundo ciclo, decorrente da avaliação realizada, foi criada a distribuição EVTux para simplificar o acesso e utilização das ferramentas digitais em contexto de EVT. Finalmente, o terceiro ciclo, decorre da eliminação da disciplina de EVT do currículo do 2º ciclo do ensino básico e a sua substituição por duas novas disciplinas, tendo-se realizada a respetiva análise de conteúdo das metas curriculares e produzido a aplicação As ferramentas digitais do Mundo Visual, concebida para contextualizar e indexar as ferramentas digitais selecionadas para a nova disciplina de Educação Visual.Os resultados deste estudo apontam claramente para a possibilidade de integrar na disciplina de Educação Visual e Tecnológica (ou no presente momento, em Educação Visual) ferramentas digitais para abordagem aos conteúdos e áreas de exploração, bem como a possibilidade de se constituírem facilmente comunidades de prática (como foi o caso) que possam colaborar na catalogação destas ferramentas no contexto específico da disciplina e para a necessidade sentida pelos professores em obter informação e formação que os possa atualizar quanto à integração das TIC no currículo. Apresentam-se, ainda, as limitações deste estudo que passaram sobretudo pelo impacto negativo que a eliminação da disciplina provocou na motivação dos docentes e a sua consequente participação no decorrer de algumas fases do trabalho, e ainda da dificuldade de gestão de uma equipa de professores colaboradores tão numerosa e diversificada. Nesse sentido, são também apresentadas sugestões para estudos futuros.