55 resultados para variable sample size


Relevância:

100.00% 100.00%

Publicador:

Resumo:

With the advent of new video standards such as MPEG-4 part-10 and H.264/H.26L, demands for advanced video coding, particularly in the area of variable block size video motion estimation (VBSME), are increasing. In this paper, we propose a new one-dimensional (1-D) very large-scale integration architecture for full-search VBSME (FSVBSME). The VBS sum of absolute differences (SAD) computation is performed by re-using the results of smaller sub-block computations. These are distributed and combined by incorporating a shuffling mechanism within each processing element. Whereas a conventional 1-D architecture can process only one motion vector (MV), this new architecture can process up to 41 MV sub-blocks (within a macroblock) in the same number of clock cycles.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This letter introduces the convex variable step-size (CVSS) algorithm. The convexity of the resulting cost function is guaranteed. Simulations presented show that with the proposed algorithm, we obtain similar results, as with the VSS algorithm in initial convergence, while there are potential performance gains when abrupt changes occur.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

For some time there is a large interest in variable step-size methods for adaptive filtering. Recently, a few stochastic gradient algorithms have been proposed, which are based on cost functions that have exponential dependence on the chosen error. However, we have experienced that the cost function based on exponential of the squared error does not always satisfactorily converge. In this paper we modify this cost function in order to improve the convergence of exponentiated cost function and the novel ECVSS (exponentiated convex variable step-size) stochastic gradient algorithm is obtained. The proposed technique has attractive properties in both stationary and abrupt-change situations. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim: To assess the sample sizes used in studies on diagnostic accuracy in ophthalmology. Design and sources: A survey literature published in 2005. Methods: The frequency of reporting calculations of sample sizes and the samples' sizes were extracted from the published literature. A manual search of five leading clinical journals in ophthalmology with the highest impact (Investigative Ophthalmology and Visual Science, Ophthalmology, Archives of Ophthalmology, American Journal of Ophthalmology and British Journal of Ophthalmology) was conducted by two independent investigators. Results: A total of 1698 articles were identified, of which 40 studies were on diagnostic accuracy. One study reported that sample size was calculated before initiating the study. Another study reported consideration of sample size without calculation. The mean (SD) sample size of all diagnostic studies was 172.6 (218.9). The median prevalence of the target condition was 50.5%. Conclusion: Only a few studies consider sample size in their methods. Inadequate sample sizes in diagnostic accuracy studies may result in misleading estimates of test accuracy. An improvement over the current standards on the design and reporting of diagnostic studies is warranted.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PurposeThe selection of suitable outcomes and sample size calculation are critical factors in the design of a randomised controlled trial (RCT). The goal of this study was to identify the range of outcomes and information on sample size calculation in RCTs on geographic atrophy (GA).MethodsWe carried out a systematic review of age-related macular degeneration (AMD) RCTs. We searched MEDLINE, EMBASE, Scopus, Cochrane Library, www.controlled-trials.com, and www.ClinicalTrials.gov. Two independent reviewers screened records. One reviewer collected data and the second reviewer appraised 10% of collected data. We scanned references lists of selected papers to include other relevant RCTs.ResultsLiterature and registry search identified 3816 abstracts of journal articles and 493 records from trial registries. From a total of 177 RCTs on all types of AMD, 23 RCTs on GA were included. Eighty-one clinical outcomes were identified. Visual acuity (VA) was the most frequently used outcome, presented in 18 out of 23 RCTs and followed by the measures of lesion area. For sample size analysis, 8 GA RCTs were included. None of them provided sufficient Information on sample size calculations.ConclusionsThis systematic review illustrates a lack of standardisation in terms of outcome reporting in GA trials and issues regarding sample size calculation. These limitations significantly hamper attempts to compare outcomes across studies and also perform meta-analyses.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

It is very common to analyse the factors associated with the onset and continuation of civil wars entirely separately, as if there were likely to be no similarity between them. This is an overstatement of the theoretical position, which has established only that they may be different (i.e. less than perfectly correlated). The hypothesis that the explanatory variables are the same is not theoretically excludable and is empirically testable, both for individual variables and for combinations of them. Starting from this approach yields a rather different picture of the factors associated with the continuation of civil wars, because the relatively small sample size means that confidence intervals on individual coefficients are wide in this case. It is shown here that country size, mountainous terrain and (in most datasets) ethnic diversity seem significant for the continuation of civil wars, starting from the null hypothesis that variables affect onset and continuation probabilities identically, rather than entirely independently. One variable that affects onset and continuation significantly differently is anocracy, which we find to matter only for onset. Civil war is more likely if it occurred two years previously, as well as one year previously, which indicates that wars are more likely to restart after only one year of peace, and also more likely to stop in their first year. The combined model strengthens the result that ethnic diversity matters (it is consistently significant across datasets, whereas it is not when onset is analysed separately), although in the UCD/PRIO dataset it is significant only for onset. By contrast, if continuation is analysed independently, virtually nothing is significant except a pre-1991 dummy and a dummy for civil war two years previously.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

An analysis is presented of VLT-FLAMES spectroscopy for three Galactic clusters, NGC3293, NGC4755 and NGC6611. Non-LTE model atmosphere calculations have been used to estimate effective temperatures (from either the helium spectrum or the silicon ionization equilibrium) and gravities (from the hydrogen spectrum). Projected rotational velocities have been deduced from the helium spectrum (for fast and moderate rotators) or the metal line spectrum (for slow rotators). The origin of the low gravity estimates for apparently near main sequence objects is discussed and is related to the stellar rotational velocity. The atmospheric parameters have been used to estimate cluster distances (which are generally in good agreement with previous determinations) and these have been used to estimate stellar luminosities and evolutionary masses. The observed Hertzsprung-Russell diagrams are compared with theoretical predictions and some discrepancies including differences in the main sequence luminosities are discussed. Cluster ages have been deduced and evidence for non-coeval star formation is found for all three of the clusters. Projected rotational velocities for targets in the older clusters, NGC3293 and NGC4755, have been found to be systematically larger than those for the field, confirming recent results in other similar age clusters. The distribution of projected rotational velocities are consistent with a Gaussian distribution of intrinsic rotational velocities. For the relatively unevolved targets in the older clusters, NGC3293 and NGC4755, the peak of the velocity distribution would be 250 km s(-1) with a full-width-half-maximum of approximately 180 km s(-1). For NGC6611, the sample size is relatively small but implies a lower mean rotational velocity. This may be evidence for the spin-down effect due to angular momentum loss through stellar winds, although our results are consistent with those found for very young high mass stars. For all three clusters we deduce present day mass functions with Gamma-values in the range of -1.5 to -1.8, which are similar to other young stellar clusters in the Milky Way.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Motivation: Many biomedical experiments are carried out by pooling individual biological samples. However, pooling samples can potentially hide biological variance and give false confidence concerning the data significance. In the context of microarray experiments for detecting differentially expressed genes, recent publications have addressed the problem of the efficiency of sample pooling, and some approximate formulas were provided for the power and sample size calculations. It is desirable to have exact formulas for these calculations and have the approximate results checked against the exact ones. We show that the difference between the approximate and the exact results can be large.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A microfluidic glass chip system incorporating a quartz crystal microbalance (QCM) to measure the square root of the viscosity-density product of room temperature ionic liquids (RTILs) is presented. The QCM covers a central recess on a glass chip, with a seal formed by tightly clamping from above outside the sensing region. The change in resonant frequency of the QCM allows for the determination of the square root viscosity-density product of RTILs to a limit of similar to 10 kg m(-2) s(-0.5). This method has reduced the sample size needed for characterization from 1.5 ml to only 30 mu l and allows the measurement to be made in an enclosed system.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: Postal and electronic questionnaires are widely used for data collection in epidemiological studies but non-response reduces the effective sample size and can introduce bias. Finding ways to increase response to postal and electronic questionnaires would improve the quality of health research. Objectives: To identify effective strategies to increase response to postal and electronic questionnaires. Search strategy: We searched 14 electronic databases to February 2008 and manually searched the reference lists of relevant trials and reviews, and all issues of two journals. We contacted the authors of all trials or reviews to ask about unpublished trials. Where necessary, we also contacted authors to confirm methods of allocation used and to clarify results presented. We assessed the eligibility of each trial using pre-defined criteria. Selection criteria: Randomised controlled trials of methods to increase response to postal or electronic questionnaires. Data collection and analysis: We extracted data on the trial participants, the intervention, the number randomised to intervention and comparison groups and allocation concealment. For each strategy, we estimated pooled odds ratios (OR) and 95% confidence intervals (CI) in a random-effects model. We assessed evidence for selection bias using Egger's weighted regression method and Begg's rank correlation test and funnel plot. We assessed heterogeneity among trial odds ratios using a Chi 2 test and the degree of inconsistency between trial results was quantified using the I 2 statistic. Main results: Postal We found 481 eligible trials.The trials evaluated 110 different ways of increasing response to postal questionnaires.We found substantial heterogeneity among trial results in half of the strategies. The odds of response were at least doubled using monetary incentives (odds ratio 1.87; 95% CI 1.73 to 2.04; heterogeneity P < 0.00001, I 2 = 84%), recorded delivery (1.76; 95% CI 1.43 to 2.18; P = 0.0001, I 2 = 71%), a teaser on the envelope - e.g. a comment suggesting to participants that they may benefit if they open it (3.08; 95% CI 1.27 to 7.44) and a more interesting questionnaire topic (2.00; 95% CI 1.32 to 3.04; P = 0.06, I 2 = 80%). The odds of response were substantially higher with pre-notification (1.45; 95% CI 1.29 to 1.63; P < 0.00001, I 2 = 89%), follow-up contact (1.35; 95% CI 1.18 to 1.55; P < 0.00001, I 2 = 76%), unconditional incentives (1.61; 1.36 to 1.89; P < 0.00001, I 2 = 88%), shorter questionnaires (1.64; 95%CI 1.43 to 1.87; P < 0.00001, I 2 = 91%), providing a second copy of the questionnaire at follow up (1.46; 95% CI 1.13 to 1.90; P < 0.00001, I 2 = 82%), mentioning an obligation to respond (1.61; 95% CI 1.16 to 2.22; P = 0.98, I 2 = 0%) and university sponsorship (1.32; 95% CI 1.13 to 1.54; P < 0.00001, I 2 = 83%). The odds of response were also increased with non-monetary incentives (1.15; 95% CI 1.08 to 1.22; P < 0.00001, I 2 = 79%), personalised questionnaires (1.14; 95% CI 1.07 to 1.22; P < 0.00001, I 2 = 63%), use of hand-written addresses (1.25; 95% CI 1.08 to 1.45; P = 0.32, I 2 = 14%), use of stamped return envelopes as opposed to franked return envelopes (1.24; 95% CI 1.14 to 1.35; P < 0.00001, I 2 = 69%), an assurance of confidentiality (1.33; 95% CI 1.24 to 1.42) and first class outward mailing (1.11; 95% CI 1.02 to 1.21; P = 0.78, I 2 = 0%). The odds of response were reduced when the questionnaire included questions of a sensitive nature (0.94; 95% CI 0.88 to 1.00; P = 0.51, I 2 = 0%). Electronic: We found 32 eligible trials. The trials evaluated 27 different ways of increasing response to electronic questionnaires. We found substantial heterogeneity among trial results in half of the strategies. The odds of response were increased by more than a half using non-monetary incentives (1.72; 95% CI 1.09 to 2.72; heterogeneity P < 0.00001, I 2 = 95%), shorter e-questionnaires (1.73; 1.40 to 2.13; P = 0.08, I 2 = 68%), including a statement that others had responded (1.52; 95% CI 1.36 to 1.70), and a more interesting topic (1.85; 95% CI 1.52 to 2.26). The odds of response increased by a third using a lottery with immediate notification of results (1.37; 95% CI 1.13 to 1.65), an offer of survey results (1.36; 95% CI 1.15 to 1.61), and using a white background (1.31; 95% CI 1.10 to 1.56). The odds of response were also increased with personalised e-questionnaires (1.24; 95% CI 1.17 to 1.32; P = 0.07, I 2 = 41%), using a simple header (1.23; 95% CI 1.03 to 1.48), using textual representation of response categories (1.19; 95% CI 1.05 to 1.36), and giving a deadline (1.18; 95% CI 1.03 to 1.34). The odds of response tripled when a picture was included in an e-mail (3.05; 95% CI 1.84 to 5.06; P = 0.27, I 2 = 19%). The odds of response were reduced when "Survey" was mentioned in the e-mail subject line (0.81; 95% CI 0.67 to 0.97; P = 0.33, I 2 = 0%), and when the e-mail included a male signature (0.55; 95% CI 0.38 to 0.80; P = 0.96, I 2 = 0%). Authors' conclusions: Health researchers using postal and electronic questionnaires can increase response using the strategies shown to be effective in this systematic review. Copyright © 2009 The Cochrane Collaboration. Published by John Wiley & Sons, Ltd.


--------------------------------------------------------------------------------

Reaxys Database Information|

--------------------------------------------------------------------------------

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We conducted a genome-wide association study testing single nucleotide polymorphisms (SNPs) and copy number variants (CNVs) for association with early-onset myocardial infarction in 2,967 cases and 3,075 controls. We carried out replication in an independent sample with an effective sample size of up to 19,492. SNPs at nine loci reached genome-wide significance: three are newly identified (21q22 near MRPS6-SLC5A3-KCNE2, 6p24 in PHACTR1 and 2q33 in WDR12) and six replicated prior observations1-4 (9p21, 1p13 near CELSR2-PSRC1-SORT1, 10q11 near CXCL12, 1q41 in MIA3, 19p13 near LDLR and 1p32 near PCSK9). We tested 554 common copy number polymorphisms (>1% allele frequency) and none met the pre-specified threshold for replication (P < 10-3). We identified 8,065 rare CNVs but did not detect a greater CNV burden in cases compared to controls, in genes compared to the genome as a whole, or at any individual locus. SNPs at nine loci were reproducibly associated with myocardial infarction, but tests of common and rare CNVs failed to identify additional associations with myocardial infarction risk.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A new microfluidic-based approach to measuring liquid thermal conductivity is developed to address the requirement in many practical applications for measurements using small (microlitre) sample size and integration into a compact device. The approach also gives the possibility of high-throughput testing. A resistance heater and temperature sensor are incorporated into a glass microfluidic chip to allow transmission and detection of a planar thermal wave crossing a thin layer of the sample. The device is designed so that heat transfer is locally one-dimensional during a short initial time period. This allows the detected temperature transient to be separated into two distinct components: a short-time, purely one-dimensional part from which sample thermal conductivity can be determined and a remaining long-time part containing the effects of three-dimensionality and of the finite size of surrounding thermal reservoirs. Identification of the one-dimensional component yields a steady temperature difference from which sample thermal conductivity can be determined. Calibration is required to give correct representation of changing heater resistance, system layer thicknesses and solid material thermal conductivities with temperature. In this preliminary study, methanol/water mixtures are measured at atmospheric pressure over the temperature range 30-50A degrees C. The results show that the device has produced a measurement accuracy of within 2.5% over the range of thermal conductivity and temperature of the tests. A relation between measurement uncertainty and the geometric and thermal properties of the system is derived and this is used to identify ways that error could be further reduced.