Resumo:
Purpose. To manufacture and characterize, through oscillatory rheology, thermoresponsive rheologically structured vehicles
(RSV’s) capable of enhanced retention times within the vagina for the purposes of HIV vaccine delivery.
Methods. Pluronics F127, F108 and F68 were investigated and RSV’s were prepared by dissolving sorbic acid (0.1% w/w)
and mucoadhesive component (Gantrez SBF97 or Noveon AA1, 3% w/w) in the required amount of H2O and NaOH.
Pluronic (10% w/w) was added via mixing in an ice-bath followed by hydroxyethylcellulose (5%) and subsequently
poly(vinylpyrollidone) (4%w/w). Oscillatory temperature sweeps between 10-38°C were preformed within the linear
viscoelastic region of the formulations on an AR2000 rheometer (T.A. Instruments, Surrey, England) with a 2cm diameter
parallel plate geometry and a plate gap of 1000µm at 1Hz.
Development of liposome-based freeze-dried rods for vaginal vaccine delivery against HIV-1 infection
Resumo:
The present investigation deals with development and characteriza- tion of the liposomes-based freeze-dried rods for the vaginal delivery of gp140 antigen in mice. Positively charged, negatively charged and neutral liposomes were prepared and characterized for various parameters e.g. morphology, size, polydispersity index, zeta potential and antigen encapsulation efficiency. To further improve the efficacy of vaccine delivery, antigen encapsulated liposomes were formulated as polymer gel-based freeze-dried rods, which were then characterized for moisture content. The redispersibility of the liposomes-based freeze- dried rods was determined in simulated vaginal fluid and liposome gel was investigated for mucoadhesion. The developed liposome-based freeze-dried rods systems could offer potential as stable and practical dosage form for the mucosal immunization against HIV-1 infection.
Resumo:
INTRODUCTION: Breaching the skin's stratum corneum barrier raises the possibility of the administration of vaccines, gene vectors, antibodies and even nanoparticles, all of which have at least their initial effect on populations of skin cells. AREAS COVERED: Intradermal vaccine delivery holds enormous potential for improved therapeutic outcomes for patients, particularly those in the developing world. Various vaccine-delivery strategies have been employed, which are discussed in this review. The importance of cutaneous immunobiology on the effect produced by microneedle-mediated intradermal vaccination is also discussed. EXPERT OPINION: Microneedle-mediated vaccines hold enormous potential for patient benefit. However, in order for microneedle vaccine strategies to fulfill their potential, the proportion of an immune response that is due to the local action of delivered vaccines on skin antigen-presenting cells, and what is due to a systemic effect from vaccines reaching the systemic circulation, must be determined. Moreover, industry will need to invest significantly in new equipment and instrumentation in order to mass-produce microneedle vaccines consistently. Finally, microneedles will need to demonstrate consistent dose delivery across patient groups and match this to reliable immune responses before they will replace tried-and-tested needle-and-syringe-based approaches.
Resumo:
INTRODUCTION: Transdermal drug delivery offers a number of advantages for the patient, not only due to its non-invasive and convenient nature, but also due to factors such as avoidance of first-pass metabolism and prevention of gastrointestinal degradation. It has been demonstrated that microneedles (MNs) can increase the number of compounds amenable to transdermal delivery by penetrating the skin's protective barrier, the stratum corneum, and creating a pathway for drug permeation to the dermal tissue below.
AREAS COVERED: MNs have been extensively investigated for drug and vaccine delivery. The different types of MN arrays and their delivery capabilities are discussed in terms of drugs, including biopharmaceutics and vaccines. Patient usage and effects on the skin are also considered.
EXPERT OPINION: MN research and development is now at the stage where commercialisation is a viable possibility. There are a number of long-term safety questions relating to patient usage which will need to be addressed moving forward. Regulatory guidance is awaited to direct the scale-up of the manufacturing process alongside provision of clearer patient instruction for safe and effective use of MN devices.
Resumo:
The potential of a microparticulate vaccine delivery system in eliciting a specific mucosal antibody response in the respiratory tract of mice was evaluated. Two vaccine candidate peptides representing epitopes from the G attachment and F fusion antigens from bovine respiratory syncytial virus (BRSV) were encapsulated into poly(dl- lactide co-glycolide) biodegradable microparticles. The encapsulation process did not denature the entrapped peptides as verified by detection of peptide-specific antibodies in mucosal secretions by ELISA using peptide as antigen. Following intranasal immunisation, the encapsulated peptides induced stronger upper and lower respiratory tract specific-IgA responses, respectively, than the soluble peptide forms. Moreover, a strong peptide-specific cell-mediated immune response was measured in splenocytes in vitro from the mice inoculated with the encapsulated peptides compared to their soluble form alone indicating that migration of primed T cells had taken place from the site of mucosal stimulation in the upper respiratory tract to the spleen. These results act as a foundation for vaccine efficacy studies in large animal BRSV challenge models.
Resumo:
Research based upon microneedle (MN) arrays has intensified recently. While the initial focus was on biomolecules, the field has expanded to include delivery of conventional small-molecule drugs whose water solubility currently precludes transdermal administration. Much success has been achieved, with peptides, proteins, vaccines, antibodies and even particulates delivered by MN in therapeutic/prophylactic doses. Recent innovations have focused on enhanced formulation design, scalable manufacture and extension of exploitation to minimally invasive patient monitoring, ocular delivery and enhanced administration of cosmeceuticals. Only two MN-based drug/vaccine delivery products are currently marketed, partially due to limitations with older MN designs based upon silicon and metal. Even the more promising polymeric MN have raised a number of regulatory and manufacturability queries that the field must address. MN arrays have tremendous potential to yield real benefits for patients and industry and, through diligence, innovation and collaboration, this will begin to be realised over the next 3-5 years.