247 resultados para urea breath test


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report the results of general practitioners' views on Helicobacter pylori-associated dyspepsia and use of screening tests in the community. The use of office serology tests in screening is of concern as independent validation in specialist units has been disappointing.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Although the 13C-urea breath test is commonly used for detection of Helicobacter pylori infection and eradication, access to commercial testing centres for analysis may at times limit its use. We have addressed this issue by establishing a regional-based means of analysis as a Hospital-University collaboration.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives To investigate the effects of Helicobacter pylori infection and its eradication on heartburn and gastro-oesophageal reflux. Design Cross sectional study, followed by a randomised placebo controlled trial. Setting Seven general practices in Bristol, England. Participants 10 537 people, aged 20-59 years, with and without H pylori infection (determined by the 13C-urea breath test). Main outcome measures Prevalence of heartburn and gastro-oesophageal acid reflux at baseline and two years after treatment to eradicate H pylori infection. Results At baseline, H pylori infection was associated with increased prevalence of heartburn (odds ratio 1.14, 95% confidence interval 1.05 to 1.23) but not reflux (1.05, 0.97 to 1.14). In participants with H pylori infection, active treatment had no effect on the overall prevalence of heartburn (0.99, 0.88 to 1.12) or reflux (1.04, 0.91 to 1.19) and did not improve pre-existing symptoms of heartburn or reflux. Conclusions H pylori infection is associated with a slightly increased prevalence of heartburn but not reflux. Treatment to eradicate H pylori has no net benefit in patients with heartburn or gastro-oesophageal reflux

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Exhaled breath temperature (EBT) reflects airways (both eosinophilic and neutrophilic) inflammation in asthma and thus may aid the management of children with asthma that are treated with anti-inflammatory drugs. A new EBT monitor has become available that is cheap and easy to use and may be a suitable monitoring device for airways inflammation. Little is known about how EBT relates to asthma treatment decisions, disease control, lung function, or other non-invasive measures of airways inflammation, such as exhaled nitric oxide (ENO).

OBJECTIVE: To determine the relationships between EBT and asthma treatment decision, current control, pulmonary function, and ENO.

METHODS: Cross-sectional prospective study on 159 children aged 5-16 years attending a pediatric respiratory clinic. EBT was compared with the clinician's decision regarding treatment (decrease, no change, increase), asthma control assessment (controlled, partial, uncontrolled), level of current treatment (according to British Thoracic Society guideline, BTS step), ENO, and spirometry.

RESULTS: EBT measurement was feasible in the majority of children (25 of 159 could not perform the test) and correlated weakly with age (R = 0.33, P = <0.01). EBT did not differ significantly between the three clinician decision groups (P = 0.42), the three asthma control assessment groups (P = 0.9), or the current asthma treatment BTS step (P = 0.57).

CONCLUSIONS & CLINICAL IMPLICATIONS: EBT measurement was not related to measures of asthma control determined at the clinic. The routine intermittent monitoring of EBT in children prescribed inhaled corticosteroids who attend asthma clinics cannot be recommended for adjusting anti-inflammatory asthma therapy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Lung clearance index (LCI) derived from sulfur hexafluoride (SF6) multiple breath washout (MBW) is a sensitive measure of lung disease in people with cystic fibrosis (CF). However, it can be time-consuming, limiting its use clinically. Aim: To compare the repeatability, sensitivity and test duration of LCI derived from washout to 1/30th (LCI1/30), 1/20th (LCI1/20) and 1/10th (LCI1/10) to ‘standard’ LCI derived from washout to 1/40th initial concentration (LCI1/40). Methods: Triplicate MBW test results from 30 clinically stable people with CF and 30 healthy controls were analysed retrospectively. MBW tests were performed using 0.2% SF6 and a modified Innocor device. All LCI end points were calculated using SimpleWashout software. Repeatability was assessed using coefficient of variation (CV%). The proportion of people with CF with and without abnormal LCI and forced expiratory volume in 1 s (FEV1) % predicted was compared. Receiver operating characteristic (ROC) curve statistics were calculated. Test duration of all LCI end points was compared using paired t tests. Results: In people with CF, LCI1/40 CV% (p=0.16), LCI1/30 CV%, (p=0.53), LCI1/20 CV% (p=0.14) and LCI1/10 CV% (p=0.25) was not significantly different to controls. The sensitivity of LCI1/40, LCI1/30 and LCI1/20 to the presence of CF was equal (67%). The sensitivity of LCI1/10 and FEV1% predicted was lower (53% and 47% respectively). Area under the ROC curve (95% CI) for LCI1/40, LCI1/30, LCI1/20, LCI1/10 and FEV1% predicted was 0.89 (0.80 to 0.97), 0.87 (0.77 to 0.96), 0.87 (0.78 to 0.96), 0.83 (0.72 to 0.94) and 0.73 (0.60 to 0.86), respectively. Test duration of LCI1/30, LCI1/20 and LCI1/10 was significantly shorter compared with the test duration of LCI1/40 in people with CF (p<0.0001) equating to a 5%, 9% and 15% time saving, respectively. Conclusions: In this study, LCI1/20 was a repeatable and sensitive measure with equal diagnostic performance to LCI1/40. LCI1/20 was shorter, potentially offering a more feasible research and clinical measure.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Multiple breath wash-out (MBW) testing requires prior wash-in of inert tracer gas. Wash-in efficiency can be enhanced by a rebreathing tracer in a closed circuit. Previous attempts to deploy this did not account for the impact of CO2 accumulation on patients and were unsuccessful. We hypothesised that an effective rebreathe wash-in could be delivered and it would not alter wash-out parameters. Computer modelling was used to assess the impact of the rebreathe method on wash-in efficiency. Clinical testing of open and closed circuit wash-in–wash-out was performed in healthy controls and adult patients with cystic fibrosis (CF) using a circuit with an effective CO2 scrubber and a refined wash-in protocol. Wash-in efficiency was enhanced by rebreathing. There was no difference in mean lung clearance index between the two wash-in methods for controls (6.5 versus 6.4; p=0.2, n=12) or patients with CF (10.9 versus 10.8; p=0.2, n=19). Test time was reduced by rebreathe wash-in (156 versus 230 s for CF patients, p<0.001) and both methods were well tolerated. End wash-in CO2 was maintained below 2% in most cases. Rebreathe–wash-in is a promising development that, when correctly deployed, reduces wash-in time and facilitates portable MBW testing. For mild CF, wash-out outcomes are equivalent to an open circuit.

Relevância:

20.00% 20.00%

Publicador: