3 resultados para parallel robots,cable driven,underactuated,calibration,sensitivity,accuracy


Relevância:

100.00% 100.00%

Publicador:

Resumo:

There have been over 3000 bridge weigh-in-motion (B-WIM) installations in 25 countries worldwide, this has led vast improvements in post processing of B-WIM systems since its introduction in the 1970’s. This paper introduces a new low-power B-WIM system using fibre optic sensors (FOS). The system consisted of a series of FOS which were attached to the soffit of an existing integral bridge with a single span of 19m. The site selection criteria and full installation process has been detailed in the paper. A method of calibration was adopted using live traffic at the bridge site and based on this calibration the accuracy of the system was determined.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We report the self-assembly of a new family of hydrophobic,bis(pyridyl) PtII complexes featuring an extendedoligophenyleneethynylene-derived π-surface appended withsix long (dodecyloxy (2)) or short (methoxy (3)) side groups.Complex 2, containing dodecyloxy chains, forms fibrous assemblies with a slipped arrangement of the monomer units (dPt···Pt… =14 Å) in both nonpolar solvents and the solid state.Dispersion-corrected PM6 calculations suggest that this organizationis driven by cooperative π–π, C-H···Cl and π–Pt interactions, which is supported by EXAFS and 2D NMR spectroscopic analysis. In contrast, nearly parallel π-stacks (dPt···Pt… = 4.4 Å) stabilized by multiple π–π and C-H···Cl contact sare obtained in the crystalline state for 3 lacking longside chains, as shown by X-ray analysis and PM6 calculations.Our results reveal not only the key role of alkyl chain lengthin controlling self-assembly modes but also show the relevanceof Pt-bound chlorine ligands as new supramolecular synthons.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A small scale sample nuclear waste package, consisting of a 28 mm diameter uranium penny encased in grout, was imaged by absorption contrast radiography using a single pulse exposure from an X-ray source driven by a high-power laser. The Vulcan laser was used to deliver a focused pulse of photons to a tantalum foil, in order to generate a bright burst of highly penetrating X-rays (with energy >500 keV), with a source size of <0.5 mm. BAS-TR and BAS-SR image plates were used for image capture, alongside a newly developed Thalium doped Caesium Iodide scintillator-based detector coupled to CCD chips. The uranium penny was clearly resolved to sub-mm accuracy over a 30 cm2 scan area from a single shot acquisition. In addition, neutron generation was demonstrated in situ with the X-ray beam, with a single shot, thus demonstrating the potential for multi-modal criticality testing of waste materials. This feasibility study successfully demonstrated non-destructive radiography of encapsulated, high density, nuclear material. With recent developments of high-power laser systems, to 10 Hz operation, a laser-driven multi-modal beamline for waste monitoring applications is envisioned.