66 resultados para maxillary expansion


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Supplementation of mesenchymal stem cells (MSCs) during hematopoietic stem cell transplantation (HSCT) alleviates complications such as graft-versus-host disease, leading to a speedy recovery of hematopoiesis. To meet such clinical demand, a fast MSCs expansion method is required. In the present study, we examined the feasibility of expanding MSCs from the isolated bone marrow mononuclear cells using a rotary bioreactor system. The cells were cultured in a rotary bioreactor with Myelocult� medium containing a combination of supplementary factors, including stem cell factor (SCF), interleukin 3 and 6 (IL-3, IL-6). After 8 days of culture, total cell numbers, Stro-1+CD44+CD34- MSCs and CD34+CD44+Stro-1- HSCs were increased 9, 29, and 8 folds respectively. Colony forming efficiency-fibroblast per day (CFE-F/day) of the bioreactor-treated cells was 1.44-fold higher than that of the cells without bioreactor treatment. The bioreactor-expanded MSCs showed expression of primitive MSCs markers endoglin (SH2) and vimentin, whereas markers associated with lineage differentiation including osteocalcin (osteogenesis), Type II collagen (chondrogenesis) and C/EBPα (adipogenesis) were not detected. Upon induction, the bioreactor-expanded MSCs were able to differentiate into osteoblasts, chondrocytes and adipocytes. Taken together, we conclude that the rotary bioreactor with the modified Myelocult� medium reported in this study may be used to rapidly expand MSCs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To assess 3-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT) techniques to see whether doses to critical structures could be reduced while maintaining planning target volume (PTV) coverage in patients receiving conventional radiotherapy (RT) for carcinoma of the maxillary sinus because of the risk of radiation-induced complications, particularly visual loss. Six patients who had recently received conventional RT for carcinoma of the maxillary sinus were studied. Conventional RT, 3D-CRT, and step-and-shoot IMRT plans were prepared using the same 2-field arrangement. The effect of reducing the number of segments in the IMRT beams was investigated. 3D-CRT and IMRT reduced the brain and ipsilateral parotid gland doses compared with the conventional plans. IMRT reduced doses to both optic nerves; for the contralateral optic nerve, 15-segment IMRT plans delivered an average maximal dose of 56.4 Gy (range 53.9–59.3) compared with 65.7 Gy (range 65.3–65.9) and 64.2 Gy (range 61.4–65.6) for conventional RT and 3D-CRT, respectively. IMRT also gave improved PTV homogeneity and improved coverage, with an average of 8.5% (range 7.0–11.7%) of the volume receiving

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The regulation of CD4 T cell numbers during an immune response should take account of the amount of antigen (Ag), the initial frequency of Ag-specific T cells, the mix of naive versus experienced cells, and (ideally) the diversity of the repertoire. Here we describe a novel mechanism of T cell regulation that potentially deals with all of these parameters. We found that CD4 T cells establish a negative feedback loop by capturing their cognate MHC/peptide complexes from Ag-presenting cells and presenting them to Ag-experienced CD4 T cells, thereby inhibiting their recruitment into the response while allowing recruitment of naive T cells. The inhibition is Ag specific, begins at day 2 (long before Ag disappearance), and cannot be overcome by providing new Ag-loaded dendritic cells. In this way CD4 T cell proliferation is regulated in a functional relationship to the amount of Ag, while allowing naive T cells to generate repertoire variety.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The constant bearing angle (CBA) strategy is a prospective strategy that permits the interception of moving objects. The purpose of the present study is to test this strategy. Participants were asked to walk through a virtual environment and to change, if necessary, their walking speed so as to intercept approaching targets. The targets followed either a rectilinear or a curvilinear trajectory and target size was manipulated both within trials (target size was gradually changed during the trial in order to bias expansion) and between trials (targets of different sizes were used). The curvature manipulation had a large effect on the kinematics of walking, which is in agreement with the CBA strategy. The target size manipulations also affected the kinematics of walking. Although these effects of target size are not predicted by the CBA strategy, quantitative comparisons of observed kinematics and the kinematics predicted by the CBA strategy showed good fits. Furthermore, predictions based on the CBA strategy were deemed superior to predictions based on a required velocity (V-REQ) model. The role of target size and expansion in the prospective control of walking is discussed.