17 resultados para Remotely Monitoring Exercise, Cardiac Rehabiliation
Resumo:
Perceptions of exercise among nonattenders of cardiac rehabilitation (CR) were explored using semistructured interviews. Analysis indicated that participants did not recognize the cardiovascular benefits of exercise, and perceived keeping
active through daily activities as sufficient for health. Health professionals were perceived to downplay the importance of exercise and CR, and medication was viewed as being more important than exercise for promoting health. The content of CR programmes and the benefits of exercise need to be further explained to patients post-MI, and in a manner that communicates to patients that these programmes are valued by significant others, particularly health professionals.
Resumo:
Valve and cardiac activity were simultaneously measured in the blue mussel (Mytilus edulis) in response to 10 d copper exposure. Valve movements, heart rates and heart-rate variability were obtained non-invasively using a Musselmonitor(R) (valve activity) and a modified version of the Computer-Aided Physiological Monitoring system (CAPMON; cardiac activity). After 2 d exposure of mussels (4 individuals per treatment group) to a range of dissolved copper concentrations (0 to 12.5 mu M as CuCl2) median valve positions (% open) and median heart rates (beats per minute) declined as a function of copper concentration. Heart-rate variability (coefficient of variation for interpulse durations) rose in a concentration-dependent manner. The 48 h EC50 values (concentrations of copper causing 50% change) for valve positions, heart rates and heart-rate variability were 2.1, 0.8, and 0.06 mu M, respectively. Valve activity was weakly correlated with both heart rate (r = 0.48 +/- 0.02) and heart-rate variability (r = 0.32 +/- 0.06) for control individuals (0 mu M Cu2+). This resulted from a number of short enclosure events that did not coincide with a change in cardiac activity. Exposure of mussels to increasing copper concentrations (greater than or equal to 0.8 mu M) progressively reduced the correlation between valve activity and heart rates (r = 0 for individuals dosed with greater than or equal to 6.3 mu M Cu2+), while correlations between valve activity and heart-rate variability were unaffected. The poor correlations resulted from periods of valve flapping that were not mimicked by similar fluctuations in heart rate or heart-rate variability. The data suggest that the copper-induced bradycardia observed in mussels is not a consequence of prolonged valve closure.
Resumo:
The LifeShirt is a novel ambulatory monitoring system that records cardio respiratory measurements outside the laboratory. Validity and reliability of cardiorespiratory measurements recorded by the LifeShirt were assessed and two methods of calibrating the LifeShirt were compared. Participants performed an incremental treadmill test and a constant work rate test (65% peak oxygen uptake) on four occasions (>48 In apart) and wore the LifeShirt, COSMED system and Polar Sport Tester simultaneously. The LifeShirt was calibrated using two methods: comparison to a spirometer; and 800 ml fixed-volume bag. Ventilation, respiratory rate, expiratory time and heart rate recorded by the LifeShirt were compared to measurements recorded by laboratory equipment. Sixteen adults participated (6M: 10F); mean (SD) age 23.1 (2.9) years. Agreement between the LifeShirt and laboratory equipment was acceptable. Agreement for ventilation was improved by calibrating the LifeShirt using a spirometer. Reliability was similar for the LifeShirt and the laboratory equipment. This study suggests that the LifeShirt provides a valid and reliable method of ambulatory monitoring. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
A real-time VHF swept frequency (20–300 MHz) reflectometry measurement for radio-frequency capacitive-coupled atmospheric pressure plasmas is described. The measurement is scalar, non-invasive and deployed on the main power line of the plasma chamber. The purpose of this VHF signal injection is to remotely interrogate in real-time the frequency reflection properties of plasma. The information obtained is used for remote monitoring of high-value atmospheric plasma processing. Measurements are performed under varying gas feed (helium mixed with 0–2% oxygen) and power conditions (0–40 W) on two contrasting reactors. The first is a classical parallel-plate chamber driven at 16 MHz with well-defined electrical grounding but limited optical access and the second is a cross-field plasma jet driven at 13.56 MHz with open optical access but with poor electrical shielding of the driven electrode. The electrical measurements are modelled using a lumped element electrical circuit to provide an estimate of power dissipated in the plasma as a function of gas and applied power. The performances of both reactors are evaluated against each other. The scalar measurements reveal that 0.1% oxygen admixture in helium plasma can be detected. The equivalent electrical model indicates that the current density between the parallel-plate reactor is of the order of 8–20 mA cm-2 . This value is in accord with 0.03 A cm-2 values reported by Park et al (2001 J. Appl. Phys. 89 20–8). The current density of the cross-field plasma jet electrodes is found to be 20 times higher. When the cross-field plasma jet unshielded electrode area is factored into the current density estimation, the resultant current density agrees with the parallel-plate reactor. This indicates that the unshielded reactor radiates electromagnetic energy into free space and so acts as a plasma antenna.
Resumo:
The effectiveness of lifestyle interventions within secondary prevention of coronary heart disease(CHD)remains unclear.This systematic review aimed to determine their effectiveness and included randomized controlled trials of lifestyle interventions, in primary care or community settings, with a minimum follow-up of three months, published since 1990. 21 trials with 10,799 patients were included; the interventions were multifactorial (10), educational (4), psychological (3), dietary (1), organisational (2), and exercise(1). The overall results for modifiable risk factors suggested improvements in dietary and exercise outcomes but no overall effect on smoking outcomes. In trials that examined mortality and morbidity,significant benefits were reported for total mortality (in 4 of 6 trials;overall risk ratio(RR) 0.75 (95%confidence intervals (CI) 0.65, 0.87)), cardiovascular mortality (3 of 8 trials; overall RR 0.63(95%CI 0.47, 0.84)), and nonfatal cardiac events(5 of 9 trials; overall RR 0.68(95%CI 0.55, 0.84)). The heterogeneity between trials and generally poor quality of trials make any concrete conclusions difficult. However, the beneficial effects observed in this review are encouraging and should stimulate further research.
Resumo:
Background: Unexplained persistent breathlessness in patients with difficult asthma despite multiple treatments is a common clinical problem. Cardiopulmonary exercise testing (CPX) may help identify the mechanism causing these symptoms, allowing appropriate management.
Methods: This was a retrospective analysis of patients attending a specialist-provided service for difficult asthma who proceeded to CPX as part of our evaluation protocol. Patient demographics, lung function, and use of health care and rescue medication were compared with those in patients with refractory asthma. Medication use 6 months following CPX was compared with treatment during CPX.
Results: Of 302 sequential referrals, 39 patients underwent CPX. A single explanatory feature was identified in 30 patients and two features in nine patients: hyperventilation (n = 14), exercise-induced bronchoconstriction (n = 8), submaximal test (n = 8), normal test (n = 8), ventilatory limitation (n = 7), deconditioning (n = 2), cardiac ischemia (n = 1). Compared with patients with refractory asthma, patients without “pulmonary limitation” on CPX were prescribed similar doses of inhaled corticosteroid (ICS) (median, 1,300 µg [interquartile range (IQR), 800-2,000 µg] vs 1,800 µg [IQR, 1,000-2,000 µg]) and rescue oral steroid courses in the previous year (median, 5 [1-6] vs 5 [1-6]). In this group 6 months post-CPX, ICS doses were reduced (median, 1,300 µg [IQR, 800-2,000 µg] to 800 µg [IQR, 400-1,000 µg]; P < .001) and additional medication treatment was withdrawn (n = 7). Patients with pulmonary limitation had unchanged ICS doses post CPX and additional therapies were introduced.
Conclusions: In difficult asthma, CPX can confirm that persistent exertional breathlessness is due to asthma but can also identify other contributing factors. Patients with nonpulmonary limitation are prescribed inappropriately high doses of steroid therapy, and CPX can identify the primary mechanism of breathlessness, facilitating steroid reduction.
Resumo:
Concrete structures in marine environments are subjected to cyclic wetting and drying, corrosion of reinforcement due to chloride ingress and biological deterioration. In order to assess the quality of concrete and predict the corrosion activity of reinforcing steel in concrete in this environment, it is essential to monitor the concrete continuously right from the construction phase to the end of service life of the structure. In this paper a novel combination of sensor techniques which are integrated in a sensor probe is used to monitor the quality of cover concrete and corrosion of the reinforcement. The integrated sensor probe was embedded in different concrete samples exposed to an aggressive marine environment at the Hangzhou Bay Bridge in China. The sensor probes were connected to a monitoring station, which enabled the access and control of the data remotely from Belfast, UK. The initial data obtained from the monitoring station reflected the early age properties of the concretes and distinct variations in these properties were observed with different concrete types.
Resumo:
This paper discusses the importance of integrated sensing systems comprising techniques that give different types of data from a structure exposed to the marine environment so that its service life could reliably be predicted. For this purpose, a novel sensor combination was designed and installed in concrete panels which were exposed to Hangzhou Bay Bridge in China. The integrated sensor probe was used to monitor the cover concrete as well as the reinforcement. The sensor probes were connected to a monitoring station, which enabled access and control of the data remotely from Belfast, UK. The initial data obtained from the monitoring station gives interesting information on the early age properties of concrete and distinct variations in these properties with different types of concrete. This paper also reports the variation in electrical properties of different concrete samples and environmental data in response to the marine exposure condition at Hangzhou bay bridge.
Resumo:
To ascertain if motivational techniques and a structured exercise programme can increase activity in adolescents afflicted with congenital heart disease (CHD).
Resumo:
The monitoring of oral disease is important, not alone for oral health, but for the detection and prevention of
systemic disease. The link between oral health and systemic disease is the focus of many studies, with
indications emerging of a causal link [1]. For disease diagnostics, blood has typically been the fluid of choice
for analysis, the retrieval of which is invasive and therefore unsuitable for wearable technology. Analysis of
saliva, however, is less invasive than that of blood, requires little or no pre-treatment and is abundantly
available. A strong correlation has been found between the analytes of blood and saliva [2] with saliva
containing biomarkers for diseases such as diabetes, oral cancer and cardiovascular disease. The development of
an implantable multi-parametric wireless sensor, to monitor both salivary analytes and changes in gingival
temperature, is the aim of this research project.
The aim of our current study is to detect changes in salivary pH, using a gold electrode with a pHsensitive
iridium oxide layer, and an Ion Sensitive Field Effect Transistor probe. Characterisation studies were
carried out in artificial saliva (AS). A salivary pH of between 4.5pH-7.5pH [3], and gingival temperature
between 35°C-38°C [4], were identified as the target range of interest for the human oral environment. Sensor
measurements were recorded in solutions of varying pH and temperature. An ISFET probe was then implanted
into a prototype denture and characterised in AS. This study demonstrates the suitability of ISFET and gold
electrode pH sensors for incorporation into implantable oral sensors.
[1] G. Taylor and W. Borgnakke, “Periodontal disease: associations with diabetes, glycemic control and
complications,” Oral Dis., vol. 14, no. 3, pp. 191–203, Apr. 2008.
[2] E. Tékus, M. Kaj, E. Szabó, N. L. Szénási, I. Kerepesi, M. Figler, R. Gábriel, and M. Wilhelm,
“Comparison of blood and saliva lactate level after maximum intensity exercise,” Acta Biol. Hung., vol. 63
Suppl 1, pp. 89–98, 2012.
[3] S. Naveen, M. L. Asha, G. Shubha, A. Bajoria, and A. Jose, “Salivary Flow Rate, pH and Buffering
Capacity in Pregnant and Non Pregnant Women - A Comparative Study,” JMED Res., pp. 1–8, Feb. 2014.
[4] A. F. Holthuis and F. S. Chebib, “Observations on temperature and temperature patterns of the gingiva. I.
The effect of arch, region and health,” J. Periodontol., vol. 54, no. 10, pp. 624–628, Oct. 1983
Resumo:
This laboratory session provides hands-on experience for students to visualize the beating human heart with ultrasound imaging. Simple views are obtained from which students can directly measure important cardiac dimensions in systole and diastole. This allows students to derive, from first principles, important measures of cardiac function, such as stroke volume, ejection fraction, and cardiac output. By repeating the measurements from a subject after a brief exercise period, an increase in stroke volume and ejection fraction are easily demonstrable, potentially with or without an increase in left ventricular end-diastolic volume (which indicates preload). Thus, factors that affect cardiac performance can readily be discussed. This activity may be performed as a practical demonstration and visualized using an overhead projector or networked computers, concentrating on using the ultrasound images to teach basic physiological principles. This has proved to be highly popular with students, who reported a significant improvement in their understanding of Frank-Starling's law of the heart with ultrasound imaging.