Simultaneous, long-term monitoring of valve and cardiac activity in the blue mussel Mytilus edulis exposed to copper


Autoria(s): Curtis, Timothy; Williamson, R.; Depledge, M.H.
Data(s)

2000

Resumo

Valve and cardiac activity were simultaneously measured in the blue mussel (Mytilus edulis) in response to 10 d copper exposure. Valve movements, heart rates and heart-rate variability were obtained non-invasively using a Musselmonitor(R) (valve activity) and a modified version of the Computer-Aided Physiological Monitoring system (CAPMON; cardiac activity). After 2 d exposure of mussels (4 individuals per treatment group) to a range of dissolved copper concentrations (0 to 12.5 mu M as CuCl2) median valve positions (% open) and median heart rates (beats per minute) declined as a function of copper concentration. Heart-rate variability (coefficient of variation for interpulse durations) rose in a concentration-dependent manner. The 48 h EC50 values (concentrations of copper causing 50% change) for valve positions, heart rates and heart-rate variability were 2.1, 0.8, and 0.06 mu M, respectively. Valve activity was weakly correlated with both heart rate (r = 0.48 +/- 0.02) and heart-rate variability (r = 0.32 +/- 0.06) for control individuals (0 mu M Cu2+). This resulted from a number of short enclosure events that did not coincide with a change in cardiac activity. Exposure of mussels to increasing copper concentrations (greater than or equal to 0.8 mu M) progressively reduced the correlation between valve activity and heart rates (r = 0 for individuals dosed with greater than or equal to 6.3 mu M Cu2+), while correlations between valve activity and heart-rate variability were unaffected. The poor correlations resulted from periods of valve flapping that were not mimicked by similar fluctuations in heart rate or heart-rate variability. The data suggest that the copper-induced bradycardia observed in mussels is not a consequence of prolonged valve closure.

Identificador

http://pure.qub.ac.uk/portal/en/publications/simultaneous-longterm-monitoring-of-valve-and-cardiac-activity-in-the-blue-mussel-mytilus-edulis-exposed-to-copper(ab2c4c19-3bcf-4d7a-ae92-54127d949ec2).html

Idioma(s)

eng

Direitos

info:eu-repo/semantics/restrictedAccess

Fonte

Curtis , T , Williamson , R & Depledge , M H 2000 , ' Simultaneous, long-term monitoring of valve and cardiac activity in the blue mussel Mytilus edulis exposed to copper ' Marine Biology , vol 136 , no. 5 , pp. 837-846 .

Palavras-Chave #/dk/atira/pure/subjectarea/asjc/1100/1104 #Aquatic Science
Tipo

article